122
70291301
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NetMaster Troubleshooting
60. Control Has No Display
Please see following 2 pages for wiring diagram information.
Is there 24 VAC across
H1-1 & H1-3 on
the control?
Replace Electronic
Control.
Is there power supplied
to the unit?
NO
Is there 120 VAC at input
of primary fuses?
Is there 120 VAC at
output side of the
primary fuses?
Is there 120 VAC across
terminals 1 & 2 of
transformer primary?
Plug unit in and
start cycle.
Correct wiring
between primary
fuse and power
supply.
Replace primary
fuse(s).
Correct wiring
between primary
fuse and
transformer.
Is there 24 VAC across
terminals 1 &
4 of transformer
secondary?
Replace
transformer.
Is there 24 VAC at
the input of the
secondary fuse?
Is there 24 VAC at
output side of
secondary fuse?
Correct wiring
between secondary
fuse and
transformer.
Replace secondary
fuse.
Correct wiring
between control and
secondary fuse.
YES
NO
NO
YES
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
(8)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
TMB249
S
Gas, steam and electric heat.
Single and three phase power supply.
TMB249S