118
70291301
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Micro Display Control Troubleshooting
Electric Models
Schematic
TMB1774S
L3
L2
L1
SERVICE
CONNECTION
TB3
1
2
3
4
TB1-L1
TB1-L2
TB1-L3
BLK/
WHT
BLK/
WHT
PRIMARY
FUSES
AGC-2A
250V
BLK
BLK
1
2
HEATING ELEMENTS
SECONDARY
FUSE
MDL-3.5A
250V
M
FAN MOTOR
CENTRIFUGAL
SWITCH
DOOR
SWITCH
WHT
CHASSIS GROUND
WHT
LINT
PANEL
SWITCH
AIR FLOW
SWITCH
RED
RED
RED/WHT
N.O.
COM
COM
N.O.
BRN/RED
WHT
ORG/BRN
COM
N.O.
ORG
BRN
ORG/ WHT
WHT/
BRN
BRN/WHT
N.C.
BLK
THERMISTOR
M
14
13
RED/BLU
WHT
RED/WHT
RED/BLK
WHT/VLT
WHT
RED/BLK
RED/BLK
RED
WHT/BLU
SECONDARY
FUSE
1.25 T
250V
RED
RED
WHT
GRN/YEL
WHT
1
2
3
4
5
6
7
8
9
10
WHT
WHT
THERMISTOR
BLK
WHT
H4
025 & 030 MODELS
035 MODELS
CABINET
LIMIT
THERMOSTAT
STOVE
LIMIT
THERMOSTAT
VLT
VLT/WHT
TB1-L3
TB1-L2
TB1-L1
SEE
TRANSFORMER
CONFIGURATION
JUMPER
HC2
L3
T3
T1
L1
HC2
HC1
HC2
HC1
HC1
L3
T3
H3
H5
L2
T2
L2
T2
H2
H4
L1
T1
H1
H6
24V
4.0A
24V
1.5A
12
3
4
5
6
1
AUX
THERM
PROT.
4
MAIN 1
MAIN 2
RUN
5
RUN
MAIN 2
MAIN 1
4
FAN
MOTOR
THERM
PROT.
AUX
1
CYLINDER
MOTOR
BLU/BLK
3
GRY/BLK
M
BLK
BLK/WHT
BLK/RED
L1
L2
L3
T1
T2
T3
MM
LT. BLU
LT. BLU
NOTES:
1. DOOR SWITCH - CONTACTS CLOSED WHEN DOOR CLOSED.
2. MOTOR IS PROTECTED BY INTERNAL THERMAL PROTECTOR.
3. HEATER RELAY OPENS WHEN TEMPERATURE IS REACHED.
208V
CONFIGURATION
JUMPER
200-208V MODELS
240V
CONFIGURATION
JUMPER
230-240V MODELS
12
3
45
6
6
5
4
3
2
1
TRANSFORMER
CONFIGURATION
JUMPER DETAILS
1
2
2
1
HC1
HC2
3
5
5
TEMP. REGULATING
HEAT RELAY
CIRCUIT CONTROLS
32
1
5
FS-2
H2-1
4N25
24Vac Ret
24Vac
MACHINE RUNNING
H6
3
APPLICATION DETAIL
SEE VEND
H5
7
468
1
2
91
0
1
1
COIN DROPS
H1-4
H1-2
2
16
5
4
6
7
Vmax=28Vdc
Imax=5ma
H3
5
4
3
HEAT RELAY
MOTOR RELAY
START PULSE INPUT
AVAILABLE OUTPUT
TIME 20msec MIN.
Iin= 3-30ma
H3-1 & H3-2
OPTO OFF WHEN
H3-3 & H3-4
MDC CONTROL
120Vac - 6.8K ohm 5 watt
24Vac - WIRE JUMPER
240Vac - 13.6K ohm 10 watt
JUMPER H2-2 TO H2-5 AS FOLLOWS:
VOLTAGE CONFIGURATION INPUT
H2-2
H2-5
SUPPLY
POWER
CONTROL
CLOSED & SWITCH IS PRESSED
RELAY ONLY WHEN DOOR IS
CONTROL TO TURN ON MOTOR
DOOR SENSING CIRCUIT ALLOWS
24Vac Ret
24VAC
H1-1
H1-3
9
H4
10
6
7
8
1/4 watt
1
2
100 OHM
H11L1
FS-1
H2-4
H2-3
Door Sense Ret
H2-6
32
41
CARD READER READY VEND OPTION
12121212
SERVICE DOORSERVICE DOORSERVICE DOORSERVICE DOOR
SWITCHSWITCHSWITCHSWITCH
JUMPERJUMPERJUMPERJUMPER
PNK
PNK
PNK
PNK
GRY
GRY
GRY
GRY
BRN
BRN
BRN
BRN
4444
H5
33
H5H5
33
H5
5
115
5
115
22227
777
8
668
8
668
1
1
111111
10
991
0
10
991
0
CONNECTIONS TO CONTROL
MANUAL FOR PROPER
READER INSTALLATION
PLEASE CONSULT CARD
2
14
5
H6
36
75
64
H3
2
31
COIN DROP 2
(OPTIONAL)
SINGLE, DUAL AND COIN DROP READY
COIN DROP VEND OPTION
SERVICE DOOR
SWITCH
COIN VAULT
SWITCH
(OPTIONAL)
COIN DROP 1
PNK
GRY
BRN
12
VEND APPLICATION
WHT
4
RED
3
H5
25
1
WHT
BLU
BLK
BLK
7
68
9
1
0
1
1
5
H6
14
3
26
7
6
5
4
DETAILS
H3
1
2
3
T
M
B
177
4S