20
70291301
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting
7. Burner Ignites and Goes Out Repeatedly
Burner Ignites and
Goes Out Repeatedly
Is there
insufficient gas
pressure?
Check gas
supply and
pressure.
Yes
Is the cabinet
thermostat
inoperative?
Yes
Test thermostat
and replace if
inoperative.
Is the
exhaust system
improper or
inadequate?
Yes
Refer to
Installation Manual
for exhaust system
requirements.
No
Does
tumbler have
improper
orifices?
Yes
Tumbler is equipped for
type of gas specified on
serial plate. If orifices
are different from that
specified on serial plate,
obtain and install
correct orifices.
No
Is
there excessive
igniter to burner
clearance?
Yes
Clearance
should be
0.110 - 0.140 inch
(2.79 - 3.55 mm).
Is
there
inadequate
make-up air?
Yes
Refer to
Installation Manual
for make-up air
requirements.
No
Is the
thermistor
inoperative?
Yes
No
Replace
thermistor.
Is the control
heater relay
malfunctioning?
Yes
Replace control.
No
Is there
broken, loose or
incorrect
wiring?
Yes
Refer to wiring
diagram.
No
Yes
Repair damper to
working order.
Are the
back draft dampers
locked in closed
position?
No
TMB1908S
No
Is
stove limit
thermostat 1
inoperative?
Test thermostat 1
and replace if
inoperative.
No
Yes
Is
stove limit
thermostat 2
inoperative?
Test thermostat 2
and replace if
inoperative.
No
No
Yes