background image

800000

11

Section IV

Washer Operation

Start Up

When power is applied to the washer, the control will 
display PRICEINSERT COINS, the decimal point, 
and the vend price. The PRICE and INSERT COINS 
light will remain lit until the vend price has been 
satisfied. The default cycle setting is PERM PRESS, 
the wash water fill temperature is WARM, and the 
rinse water temperature is COLD. The LED’s will 
flash on PERM PRESS and will be lit on WARM at 
the start of the cycle. See Figure 2. These default 
settings are owner programmable. Refer to Section 
VIII
.

Default Mode

When using the cycle settings, the user must either 
press NORMAL, PERM PRESS or DELICATES. 
PERM PRESS, if it is the default cycle, will need to be 
selected once. When choosing NORMAL or 
DELICATES, the user must press the respective 
keypads once, the LED will blink, and the user must 
then press appropriate keypad again. 

The user will be able to select a different cycle or wash 
water temperature by pressing a cycle pad when the 
machine is in the default mode or in the first fill cycle. 
If not enough coins are entered to satisfy the vend 
price, the control will display the remaining vend price 
needed to start the cycle. If the first fill was interrupted 
to change the temperature (which requires more 
money), and the vend price is not satisfied within one 
minute, the washer control will go back to the first 
selection and the cycle will restart from the point it 
was stopped. After the first fill, all key presses will be 

ignored, allowing the washer to go through the 
complete cycle.

When a cycle is complete, the control will display 
TIME REMAINING

“00”

 until the washer door is 

opened, a key is pressed, or a coin is entered. When 
one of these three options occur, the display will revert 
back to the default mode. See Figure 2.

Cycle Sequence

Upon the start of a cycle, the Electronic Control will 
display TIME REMAINING and the total cycle time 
including one (1) minute of fill time. The appropriate 
status words will light while the machine passes 
through different cycle steps. Any coin entered after 
the first fill cycle will be added to the total coin 
counter, but user will not be able to change cycles or 
water temperature. 

Closing Washer Door

If the door is not closed when the START pad is 
pressed, 

“d:or”

 will be displayed and will flash one (1) 

second on and one (1) second off until the door is 
closed. Once door is closed, the START pad must be 
pressed again to lock door and start cycle. If the door 
does not lock within 15 seconds of being closed, 

“E:dl”

 

will be displayed indicating a door lock error and 
machine will shut off.

Signals

There are three options when a signal can be used 
during the washer operation. The owner may program 
when the signal will sound and at what volume level. 
These three options are listed below:

1. End of Cycle Signal

By default, this signal is turned off. If turned on, the 
signal sounds for three (3) seconds at the end of a 
cycle, at one of the three programmable volume 
levels (High Medium or Low).

2. Signal On Keypad Depression

By default, this signal is set at the lowest volume 
level, and sounds for a quarter of a second each 
time a keypad is pressed. This signal can be 
programmed at one of three volume levels (High 
Medium or Low).

3. Signal On Coin Drop

By default, this signal is turned off. If turned on, 
this signal will sound for a quarter of a second each 
time a coin is entered at one of the three 
programmable volume levels (High Medium or 
Low).

Figure 2

WASH

RINSE

SOAK

SPIN

PRICE

TIME REMAINING

INSERT COINS

UNBALANCE

FABRICS AND TEMPERATURES

NORMAL

HOT

PERM

PRESS

WARM

DELICATES

COLD

C742IE3A

Содержание HTE517

Страница 1: ...Programming Electronic Control Frontload Washer See Page 2 for Model Numbers Use this manual with all electronic frontload washers Part No 800000 August 1998...

Страница 2: ......

Страница 3: ...tuations that may occur It must be understood that common sense caution and carefulness are factors which cannot be built into these washers These factors MUST BE supplied by the person s installing m...

Страница 4: ...2 800000 Model Identification Information in this manual is applicable to these washer models HWF561 HWF761 SWF561 SWF661 SWF761 HTE517 HTE717 HTG519 HTG719 STE517 STE717 STG519 STG719...

Страница 5: ...Hot Wash Number of Coins SHC 31 9 Special Vend A Warm Wash Number of Coins rnC 32 10 Special Vend A Cold Wash Number of Coins CnC 33 11 Normal Wash Agitate Time nAg 34 12 Normal Rinse Agitate Time nr...

Страница 6: ...Notes 4 800000...

Страница 7: ...the six keypads of the control Power Failure Recovery If a cycle is in progress and the power fails the cycle status is saved in memory for a minimum of six years without power When the power recover...

Страница 8: ...6 800000 Notes...

Страница 9: ...EMP pads are used to select the temperature of the water used for the wash fill These pads include HOT WARM and COLD These pads allow the user to select a water temperature other than the default sett...

Страница 10: ...8 800000 Notes...

Страница 11: ...oins to satisfy the vend price When INSERT COINS is lit the three digits and decimal point show the vend price remaining to be satisfied The vend price displayed will decrease with each coin inserted...

Страница 12: ...10 800000 Notes...

Страница 13: ...ese three options occur the display will revert back to the default mode See Figure 2 Cycle Sequence Upon the start of a cycle the Electronic Control will display TIME REMAINING and the total cycle ti...

Страница 14: ...l key presses are ignored Selecting a higher priced wash temperature will stop the first fill cycle and INSERT COINS will flash one 1 second on and one 1 second off until the vend price has been satis...

Страница 15: ...ons Section X Sales Floor Feature The Electronic Control washer has a built in sales floor routine used to display all LED lights status words and the three digits with the colon and decimal point Thi...

Страница 16: ...14 800000 Notes...

Страница 17: ...ormation along with the rest of the audit information Figure 3 3 2 1 OPERATING INSTRUCTIONS Select Wash Temperature HOT WARM COLD Select Fabric Type NORMAL PERM PRESS DELICATE Load Supply Dispenser Se...

Страница 18: ...16 800000 Notes...

Страница 19: ...Figure 2 If the washer is in an active cycle rapid advance through the cycle See the Rapid Advance feature Section XII If coins have been entered see the Clear Vend feature Section XIII 2 Open the se...

Страница 20: ...18 800000 Notes...

Страница 21: ...le OPTION DESCRIPTION 1 Slg Audio Signal 2 HnC Hot Wash of Coins 3 AnC Warm Wash of Coins 4 dnC Cold Wash of Coins 5 SPA Special Vend A Days enable 6 SAS Special Vend A Start Time 7 SAE Special Vend A...

Страница 22: ...he current number that was selected from Chart 1 located on the following page 4 Locate the desired three digit number in the first column of Chart 1 on the following page 5 Press the DELICATES or the...

Страница 23: ...e Coin Input Cycle End Key Pad ON OFF 000 OFF OFF OFF OFF OFF OFF OFF 035 OFF OFF ON OFF OFF ON ON 037 OFF OFF ON OFF ON OFF ON 039 OFF OFF ON OFF ON ON ON 041 OFF OFF ON ON OFF OFF ON 043 OFF OFF ON...

Страница 24: ...VFD to the desired number of coins See Figure 9 6 Press the PERM PRESS enter keypad when the correct three digit number appears in the VFD The next option AnC will appear in the VFD NOTE To program A...

Страница 25: ...e VFD to the desired number of coins See Figure 12 6 Press the PERM PRESS enter keypad when the correct three digit number appears in the VFD The next option dnC will appear in the VFD NOTE To program...

Страница 26: ...the VFD to the desired number of coins See Figure 15 6 Press the PERM PRESS enter keypad when the correct three digit number appears in the VFD The next option SPA will appear in the VFD NOTE To prog...

Страница 27: ...e the desired three digit number in the first column of Chart 2 on the following pages 6 Press the DELICATES or the COLD keypad to increase or decrease the current three digit number until correct See...

Страница 28: ...OFF OFF OFF ON 019 OFF OFF OFF ON OFF OFF ON ON 021 OFF OFF OFF ON OFF ON OFF ON 023 OFF OFF OFF ON OFF ON ON ON 025 OFF OFF OFF ON ON OFF OFF ON 027 OFF OFF OFF ON ON OFF ON ON 029 OFF OFF OFF ON ON...

Страница 29: ...F ON ON ON 121 OFF ON ON ON ON OFF OFF ON 123 OFF ON ON ON ON OFF ON ON 125 OFF ON ON ON ON ON OFF ON 127 OFF ON ON ON ON ON ON ON 129 ON OFF OFF OFF OFF OFF OFF ON 131 ON OFF OFF OFF OFF OFF ON ON 13...

Страница 30: ...ON ON ON 209 ON ON OFF ON OFF OFF OFF ON 211 ON ON OFF ON OFF OFF ON ON 213 ON ON OFF ON OFF ON OFF ON 215 ON ON OFF ON OFF ON ON ON 217 ON ON OFF ON ON OFF OFF ON 219 ON ON OFF ON ON OFF ON ON 221 ON...

Страница 31: ...ss the PERM PRESS enter keypad when the correct hour appears in the VFD The next option SAE will appear in the VFD NOTE To program SAE Special Vend A End Time see option 7 To program other options ref...

Страница 32: ...RM PRESS enter keypad when the correct hour appears in the VFD The next option SHC will appear in the VFD NOTE To program SHC Special Vend A Hot Wash Number of Coins see option 8 To program other opti...

Страница 33: ...the desired number of coins See Figure 27 6 Press the PERM PRESS enter keypad when the correct number of coins appears in the VFD The next option rnC will appear in the VFD NOTE To program rnC Special...

Страница 34: ...the desired number of coins See Figure 30 6 Press the PERM PRESS enter keypad when the correct number of coins appears in the VFD The next option CnC will appear in the VFD NOTE To program CnC Specia...

Страница 35: ...he VFD to the desired number of coins See Figure 33 6 Press the PERM PRESS enter keypad when the correct number of coins appears in the VFD The next option nAg will appear in the VFD NOTE To program n...

Страница 36: ...TE The Normal Wash Agitate Time can be set from one 1 to 15 minutes 6 Press the PERM PRESS enter keypad when the correct number of minutes appears in the VFD The next option nrg will appear in the VFD...

Страница 37: ...E The Normal Rinse Agitate Time can be set from one 1 to 15 minutes 6 Press the PERM PRESS enter keypad when the correct number of minutes appears in the VFD The next option nEg will appear in the VFD...

Страница 38: ...igure 42 NOTE The Normal Extra Rinse Agitate Time can be set from one 1 to 15 minutes 6 Press the PERM PRESS enter keypad when the correct number of minutes appears in the VFD The next option nFg will...

Страница 39: ...ure 45 NOTE The Normal Final Rinse Agitate Time can be set from one 1 to 15 minutes 6 Press the PERM PRESS enter keypad when the correct number of minutes appears in the VFD The next option PAg will a...

Страница 40: ...ure 48 NOTE The Permanent Press Wash Agitate Time can be set from one 1 to 15 minutes 6 Press the PERM PRESS enter keypad when the correct number of minutes appears in the VFD The next option Prg will...

Страница 41: ...re 51 NOTE The Permanent Press Rinse Agitate Time can be set from one 1 to 15 minutes 6 Press the PERM PRESS enter keypad when the correct number of minutes appears in the VFD The next option PEg will...

Страница 42: ...See Figure 54 NOTE The Permanent Press Extra Rinse Agitate Time can be set from one 1 to 15 minutes 6 Press the PERM PRESS enter keypad when the correct number of minutes appears in the VFD The next...

Страница 43: ...inutes See Figure 57 NOTE The Permanent Press Final Rinse Agitate Time can be set from one 1 to 15 minutes 6 Press the PERM PRESS enter keypad when the correct number of minutes appears in the VFD The...

Страница 44: ...NOTE The Delicates Wash Agitate Time can be set from one 1 to 15 minutes 6 Press the PERM PRESS enter keypad when the correct number of minutes appears in the VFD The next option drg will appear in t...

Страница 45: ...NOTE The Delicates Rinse Agitate Time can be set from one 1 to 15 minutes 6 Press the PERM PRESS enter keypad when the correct number of minutes appears in the VFD The next option dEg will appear in t...

Страница 46: ...igure 66 NOTE The Delicates Extra Rinse Agitate Time can be set from one 1 to 15 minutes 6 Press the PERM PRESS enter keypad when the correct number of minutes appears in the VFD The next option dFg w...

Страница 47: ...inutes See Figure 69 NOTE The Delicates Final Rinse Agitate Time can be set from one 1 to 15 minutes 6 Press the PERM PRESS enter keypad when the correct number of minutes appears in the VFD The next...

Страница 48: ...LD keypad to increase or decrease the current three digit number to the desired three digit number See Figure 72 NOTE The coin value can be set from 1 to 231 6 Press the PERM PRESS enter keypad when t...

Страница 49: ...ATES or the COLD keypad to increase or decrease the current number to the desired number selected from Chart 3 See Figure 75 6 Press the PERM PRESS enter keypad when the correct three digit number app...

Страница 50: ...in the following columns The word ON or OFF indicates if the option at the top of that column is turned on or turned off when that number is entered Chart 3 dCS Default Value Normal Cycle Perm Press...

Страница 51: ...ing 005 will show in the VFD which is Power Fail Reset OFF 5 Press the DELICATES or the COLD keypad to increase or decrease the current three digit number to the desired number selected from Chart 4 S...

Страница 52: ...rupted If 133 is entered the current cycle will be saved for up to five minutes If power is not restored within five minutes the control will advance to Final Spin and will then default The minimum po...

Страница 53: ...three digit number to 000 or 128 See Figure 81 6 Press the PERM PRESS enter keypad when the correct number appears in the VFD The next option rrn will appear in the VFD NOTE To program rrn Warm Rinse...

Страница 54: ...d to increase or decrease the current three digit to 000 or 128 See Figure 84 6 Press the PERM PRESS enter keypad when the correct number appears in the VFD The next option CFg will appear in the VFD...

Страница 55: ...the current three digit number to the desired three digit number selected from Chart 5 See Figure 87 6 Press the PERM PRESS enter keypad when the correct number appears in the VFD The next option CIn...

Страница 56: ...temperature during the entire cycle or indicates fill temperature during each rinse If this option is on the LEDs will only turn on during all fill agitate steps to indicate the temperature of water u...

Страница 57: ...OFF 103 OFF ON OFF OFF ON 110 OFF ON OFF ON OFF 111 OFF ON OFF ON ON 118 OFF ON ON OFF OFF 119 OFF ON ON OFF ON 126 OFF ON ON ON OFF 127 OFF ON ON ON ON 166 ON OFF OFF OFF OFF 167 ON OFF OFF OFF ON 1...

Страница 58: ...ess the PERM PRESS enter keypad when the correct time in minutes appears in the VFD The next option CHr will appear in the VFD NOTE To program CHr Set Real Time Clock Hours see option 30 To program ot...

Страница 59: ...See Figure 93 6 Press the PERM PRESS enter keypad when the correct time in hours appears in the VFD The next option CdA will appear in the VFD NOTE To program CdA Set Real Time Clock Days see option...

Страница 60: ...day is day two 002 and so on 6 Press the PERM PRESS enter keypad when the correct day appears in the VFD The next option CdE will appear in the VFD NOTE To program CdE Set Real Time Clock Date see opt...

Страница 61: ...ss the PERM PRESS enter keypad when the correct day of the month appears in the VFD The next option COn will appear in the VFD NOTE To program COn Set Real Time Clock Month see option 33 To program ot...

Страница 62: ...M PRESS enter keypad when the correct month appears in the VFD The next option CYr will appear in the VFD NOTE To program CYr Set Real Time Clock Year see option 34 To program other options refer to t...

Страница 63: ...ct See Figure 105 6 Press the PERM PRESS enter keypad when the correct year appears in the VFD CYr will appear in the VFD NOTE To program other options refer to the appropriate section How to Exit Pro...

Страница 64: ...62 800000 Notes...

Страница 65: ...to scroll through various options until the desired option is displayed in the VFD Refer to the Audit Options List Chart 6 for an explanation of the audit options available See Figure 107 Chart 6 Aud...

Страница 66: ...CnS displayed in the VFD the audit has counted 10 009 coins Pressing the PERM PRESS pad one time will show 000 010 009 which means no millions Pressing PERM PRESS a second time will display 000 010 00...

Страница 67: ...tart a diagnostic test refer to the quick reference chart below Chart 7 For detailed information on each test read the appropriate description How to Exit Testing Feature IMPORTANT Use the following s...

Страница 68: ...how Fill Test This test will display the average fill time This average will be calculated by taking the average of the three 3 last fill times plus the most recent fill time To start test control mus...

Страница 69: ...ure 1 Control must be in Special Mode to start Refer to Section VII 2 While pressing and holding the PERM PRESS keypad with one hand press the HOT keypad with the other hand The display will light up...

Страница 70: ...68 800000 Notes...

Страница 71: ...pressing and holding the NORMAL keypad with one hand press the WARM keypad with the other hand The cycle will start in the wash fill agitate step While in the Rapid Advance Mode pressing the COLD temp...

Страница 72: ...70 800000 Notes...

Страница 73: ...ch is in the middle of satisfying a vend price and set it back to the default mode How to Clear Vend 1 Open the service door Refer to Section VI 2 While pressing and holding the NORMAL keypad with one...

Страница 74: ...72 800000 Notes...

Страница 75: ...Fail Reset option or the Power Fail Reset option is turned off the previously selected cycle pad will flash until it is pressed and the cycle will restart from the point it left off If the power fail...

Страница 76: ...74 800000 Notes...

Страница 77: ...t using the keypad It may also be used to start and stop various diagnostic tests How to Begin Communications with Micro Wand IIIE The control will go blank and the VFD will display C until the commun...

Страница 78: ...76 800000 Notes...

Страница 79: ...Vends OFF All items zero Signals Keypress End of Cycle Coin Drop ON at low volume OFF OFF Coin Value 25 Power Fail Reset OFF 5 minutes Control Configuration Daylight Savings Wash Temp Indicator Infra...