64
M411429
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
67. ELECTRONIC PACKAGE
(Automatic Pilot Ignition Models)
a. Remove control panel.
b. Close gas shut-off valve. Refer to Figure 14.
c. Disconnect igniter wire and sensor wire from
electronic package.
d. Remove two screws holding electronic package
to gas valve. Refer to Figure 12.
e. Disconnect two operator wires from electronic
package terminals.
NOTE: Refer to wiring diagram when rewiring
electronic package.
68. MAIN OR PILOT OPERATOR
(Automatic Pilot Ignition Models)
a. Remove electronic package.
b. Remove screws holding main or pilot operator
to gas valve body. Refer to Figure 13.
69. GAS VALVE
(Standing Pilot Models)
Refer to Figure 14.
a. Remove control panel.
b. Close gas shut-off valve.
c. Disconnect all wires from gas valve terminals
and disconnect gas valve pipe unions.
d. Disconnect thermocouple and pilot tube from
gas valve.
IMPORTANT: Purge air in the gas service line by
operating the tumbler in drying mode. Use pipe
compound resistant to action of L.P. Gas on all pipe
threads.
e. Remove screws holding gas valve and bracket
to stove assembly.
f. Remove spudholder from left side of valve and
plug from right side of valve.
70. OPERATOR
(Standing Pilot Models)
a. Remove control panel.
b. Close gas shut-off valve. Refer to Figure 14.
c. Disconnect wires from operator terminals
d. Remove screws holding operator to gas valve
NOTE: Refer to wiring diagram when rewiring gas
valve operator.
71. RESET ASSEMBLY
(Standing Pilot Models)
a. Remove control panel.
b. Close gas shut-off valve. Refer to Figure 14.
c. Disconnect pilot tube and thermocouple from
reset assembly.
d. Remove screws holding reset assembly to gas
valve. Refer to Figure 13.
To reduce risk of fire or explosion, check
pipe connections for gas leaks with a non-
corrosive leak detection fluid. Do not use an
open flame to check for gas leaks!
W310
WARNING