M411429
87
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
h. Remove locknut and jam nut holding fan on
motor shaft. Refer to Figure 37. Pull fan off
motor shaft.
NOTE: Fan is keyed to motor shaft and may have to
be removed using a puller. Look for a spacer washer
at the bottom of the fan keyway. Take care to avoid
losing or damaging the spacer washer.
i. Remove spacer washer from motor shaft. Refer
Figure 37
T046SE3A
FAN
LOCKNUT
JAM NUT
SPACER
WASHER
FAN HOUSING
COVER
FAN
KEY
MOTOR
PULLEY
PULLEY
KEY
MOTOR