background image

Installation/Operation

Clothes Dryer

Nonmetered and metered

Electric and Gas Models

D677I_SVG

Original Instructions
Keep These Instructions for Future Reference.

(If this machine changes ownership, this manual must accompany machine.)

www.alliancelaundry.com

Part No. 512680R10

November 2014

Содержание D677I_SVG

Страница 1: ...ered and metered Electric and Gas Models D677I_SVG Original Instructions Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine www alliancel...

Страница 2: ......

Страница 3: ...mer use WARNING Installation of unit must be performed by a quali fied installer Install clothes dryer according to manufacturer s instructions and local codes DO NOT install a clothes dryer with flex...

Страница 4: ...e Plug 27 Reverse Door if Desired 28 Wipe Out Inside of Dryer 30 Plug In the Dryer 30 Electric Dryer 30 Gas Dryer 30 Grounding Information 31 Recheck Steps 31 Check Heat Source 31 Electric Dryers 31 G...

Страница 5: ...Filter 46 Load Laundry 46 Close Loading Door 46 Set Fabric Selector 46 Insert Coins or Card 46 Start Dryer 47 Indicator Lights 47 Operation Instructions for NetMaster Dryers 47 Clean Lint Filter 47 L...

Страница 6: ...Installer Checklist 55 6 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Part No 512680R10...

Страница 7: ...rticles that have been previously cleaned in washed in soaked in or spotted with gasoline or machine oils vegetable or cooking oils cleaning waxes or chemicals dry cleaning solvents thinner anything c...

Страница 8: ...epair or replace any part of the dryer or attempt any servicing unless specifically recommended in the user main tenance instructions or in published user repair instructions that you understand and h...

Страница 9: ...in 1020 mm E 15 44 in 392 mm F 43 in 1092 mm G 4 0 in 102 mm H 15 4 in 391 mm I 26 875 in 683 mm J 0 4 in 10 mm K 8 in 203 mm L 28 in 711 mm M 23 5 in 597 mm NOTE Exhaust openings are 4 inch 102 mm me...

Страница 10: ...5 44 in 392 mm F 43 in 1092 mm G 2 8 in 70 mm H 2 3 in 60 mm I 15 4 in 391 mm J 26 875 in 683 mm K 4 in 102 mm L 0 4 in 10 mm M 8 in 203 mm N 28 in 711 mm O 23 5 in 597 mm NOTE Exhaust openings are 4...

Страница 11: ...tandard Capacity Metercase 43 in 1092 mm C High Capacity Metercase 43 875 in 1114 mm D 15 44 in 392 mm E 4 0 in 102 mm F 15 4 in 391 mm G 26 875 in 683 mm H 36 in 914 mm I 4 5 in 114 mm J 0 4 in 10 mm...

Страница 12: ...Capacity Meter Case 43 875 in 1114 mm D 15 44 in 392 mm E 2 8 in 70 mm F 2 3 in 60 mm G 15 4 in 391 mm H 26 875 in 683 mm I 4 0 in 102 mm J 36 in 914 mm K 4 5 in 114 mm L 0 4 in 10 mm M 8 in 203 mm N...

Страница 13: ...r the ease of installation and servicing For maximum drying performance we recommend that more clearance be allowed around the dry er than the clearances that are listed thorughout this manual Dimensi...

Страница 14: ...connectors for white black wire and red blue wire together FLW6R_SVG 1 1 Service Door Figure 2 WARNING Any disassembly requiring the use of tools must be performed by a suitably qualified service per...

Страница 15: ...re 4 4 Place the dryer in position and adjust the legs until the dryer is level from side to side and front to back Leveling legs can be adjusted from inside the dryer with a 1 4 in driver 5 All four...

Страница 16: ...Door DRY2652N_SVG E H D A C 3 1 Front View Closet Door DRY2637N_SVG F F 2 G 1 Closet Door 2 Centered Air Openings G 2 Openings minimum 3 Outer Wall of Enclosure Figure 4 Installation 16 Copyright Alli...

Страница 17: ...enting through rear of unit Table 1 NOTE For new installations locate top of wall vent 42 inches 106 7 cm above floor to make venting easier to connect IMPORTANT In mobile home installations gas dryer...

Страница 18: ...or flexible metal duct The male end of each section of duct must point away from the dryer Use as few elbows as possible Use of duct tape or pop rivets on all seams and joints is rec ommended if allow...

Страница 19: ...the dryer thus reduc ing the efficiency of the dryer Exhaust System For best drying results recommended maximum length of ex haust system is shown in Table 2 To prevent backdraft when dryer is not in...

Страница 20: ...thorized parts source 2 Clean Out Cover Must be provided Inspect monthly 3 Weather Hood or Sweep Elbow No cap or screen 4 24 in 610 mm Minimum Clearance to Roof Ground Figure 6 Installation 20 Copyrig...

Страница 21: ...No Screen or Cap 5 24 in 610 mm Minimum Clearance to Roof Ground 6 Exhaust Outlet 7 Air Flow 8 30 9 Clean Out Cover Inspect Monthly Figure 7 Duct Station Minimum Diameter of Collector Duct A 4 inches...

Страница 22: ...e be fore connecting it to the dryer Before tightening the connection purge remaining air from gas line to dryer until odor of gas is detected This step is required to prevent gas valve contamination...

Страница 23: ...ter than 20 ft 6 1 m Use 3 8 in 9 5 mm pipe Longer than 20 ft 6 1 m Use 1 2 in 12 7 mm pipe 5 3 8 in NPT Gas Connection Figure 9 4 Tighten all connections securely Turn on gas and check all pipe conne...

Страница 24: ...can result in a risk of electric shock Check with a qualified electrician or service person if you are in doubt as to whether the dryer is properly grounded W038 Do not modify the plug provided with...

Страница 25: ...cess cover removed for illustration purposes only NEVER operate the dryer with access cover removed 1 Ground Wire 2 Ground to Neutral Wire 3 Neutral Terminal 4 L2 Terminal 5 Center Wire Neutral 6 Stra...

Страница 26: ...NEMA Type 10 30R 2 120 12 V A C 3 240 12 V A C 4 Intermediate Fuse Box may be omitted if service entrance box is fused 5 Wall Receptacle 6 Power Supply 7 3 Wire Earth Ground Neutral 120 240 Volt 60 He...

Страница 27: ...ction before plugging the cord into an outlet Use an acceptable indicating device connected to the center earth ground pin of the plug and the green screw on the back of the cabinet 8 Reinstall access...

Страница 28: ...wire to L2 terminal c White wire to Neutral terminal NOTE When installing the white wire loop the free eyelet end of the earth ground to neutral wire re moved in Step 3 and attach along with the white...

Страница 29: ...Figure 24 5 Remove door strike from door liner and reinstall on opposite side DRY1917N_SVG Figure 25 6 Insert liner under flange on bottom of door then push top of door liner into place DRY1918N_SVG B...

Страница 30: ...ional Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 and such local regulations as might apply It is the customer s responsibility to have the wiring and fuses installed by a q...

Страница 31: ...h the dryer if it will not fit the outlet have a proper outlet installed by a qualified electrician NOTE Have a qualified electrician check the polarity of the wall receptacle If a voltage reading is...

Страница 32: ...back slowly to the right to obtain a steady soft blue flame c After the air shutter is adjusted for proper flame tighten the air shutter lockscrew securely 5 Reinstall the lower front panel WARNING F...

Страница 33: ...receives a coin slide pulse during a cycle it will add the programmed dry time to the time currently remaining in the cycle The IN USE LED will flash briefly to indicate the coin input The maximum cy...

Страница 34: ...the control will clear the cycle and return to Ready Mode if there is a power failure All Models The control is shipped from the factory programmed with 1 mi nute of minimum heat time preset with 41...

Страница 35: ...F ON OFF OFF 12 ON ON OFF ON OFF OFF 13 OFF OFF ON ON OFF OFF 14 ON OFF ON ON OFF OFF 15 OFF ON ON ON OFF OFF 16 ON ON ON ON OFF OFF 17 OFF OFF OFF OFF ON OFF 18 ON OFF OFF OFF ON OFF 19 OFF ON OFF OF...

Страница 36: ...OFF OFF OFF ON OFF ON 42 preset at fac tory ON OFF OFF ON OFF ON 43 OFF ON OFF ON OFF ON 44 ON ON OFF ON OFF ON 45 OFF OFF ON ON OFF ON 46 ON OFF ON ON OFF ON 47 OFF ON ON ON OFF ON 48 ON ON ON ON OFF...

Страница 37: ...witch settings Then set them all to the off position Refer to Figure 1 3 Plug in the machine and initiate a cycle NOTE With all the control dipswitches off the total cycle time will be four minutes lo...

Страница 38: ...6 5 4 3 2 1 1 Spring 2 Bolt 3 One or Two Flat Washers Shims 4 Rounded Corner 5 Nut 6 Extension Lever 7 Star s Facing Down 8 Extension Bracket 9 Loops Figure 36 5 Torque nut between 18 and 20 inch poun...

Страница 39: ...xtension Onto Coin Slide Option Two 1 Install coin slide according to manufacturer s instructions 2 Insert coins into coin slide and slowly push slide in Stop be fore coins fall into coin box This wil...

Страница 40: ...locknuts Refer to Figure 41 IMPORTANT Install coin slide bracket with side marked A facing up and toward extension bracket and lever assembly Refer to Figure 41 TLW2163N_SVG 3 2 1 1 Spring Installed 2...

Страница 41: ...ating properly by insert ing coins and starting a cycle The IN USE light will turn on or flash if it is already on to indicate proper operation NOTE To avoid long run down time 45 minutes fac tory def...

Страница 42: ...p objects from laundry to avoid tears and rips to items during normal machine operation Clean Lint Filter Clean lint filter before each use D608I_SVG Figure 45 Load Laundry 1 Load clothes loosely into...

Страница 43: ...TE This machine includes an extended tumble fea ture Starting 20 minutes after a cycle ends the cylin der will tumble for two minutes every hour without heat up to 18 hours or until door is opened Ope...

Страница 44: ...yer will not operate with the door open D688I_SVG Figure 53 Set Fabric Selector Select NORMAL High Temp PERM PRESS Med Temp DELICATES Low Temp or TUMBLE No Heat by pushing touchpad NOTE Always follow...

Страница 45: ...e The PUSH START status word flashes at one sec ond intervals when activated DRYING DRYING is lit to indicate that one of the heated cycles HIGH TEMP MED TEMP LOW TEMP is currently in operation The st...

Страница 46: ...ftener sheet if desired IMPORTANT To avoid damage to dryer do not use more than one fabric softener sheet per load D609I_SVG Figure 59 Close Loading Door 1 Close loading door 2 Dryer will not operate...

Страница 47: ...heated cycles HIGH TEMP MED TEMP LOW TEMP or DELICATES is currently in operation DRYING will turn off at the end of a heated cycle or when the COOL DOWN cycle be gins COOL DOWN COOL DOWN is lit whene...

Страница 48: ...or 2 Dryer will not operate with the door open D688I_SVG Figure 67 Set Fabric Selector Select Fabric Temperature by pushing touchpad NOTE Always follow manufacturer s care labels D777I_SVG Figure 68 I...

Страница 49: ...in a cycle the full vend price has been satisfied and the dryer door is closed When the START pad is pressed the cycle will begin or resume DRYING DRYING is lit to indicate that one of the heated cyc...

Страница 50: ...hol on the control panel NOTE The wiring diagram is located inside the control panel WARNING Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dan ger...

Страница 51: ...verdry clothes Remove items to be ironed while still damp Large loads of similar fabrics dry the most efficiently How ever dry permanent press in smaller loads to prevent wrin kling Use the correct te...

Страница 52: ...e timer Push coin slide all the way in Make sure the laundry room fuse s isn t blown or loose or circuit breakers aren t open The dryer itself does not have an electrical fuse An electric dryer has an...

Страница 53: ...air moving through the dryer and exhaust system Clothes are too wrinkled Check heat setting Overdrying can cause wrinkling Check load size Large loads may not tumble properly and may cause wrinkling C...

Страница 54: ...The model and serial num bers are located on the serial plate The serial plate will be in the location shown Please include a copy of your bill of sale and any service receipts you have If replacement...

Страница 55: ...lectric D275I_SVG1 Gas D254I_SVG CHECK CHECK 3 GAS ONLY Connect Gas Sup ply Pipe Check for Gas Leaks D258I_SVG1 8 Recheck Steps CHECK CHECK 4 ELECTRIC ONLY Connect Electrical Cord D699I_SVG1 9 Check H...

Отзывы: