DRY2225P_SVG
1 2 3 4 5 6 7 8
O
N
Figure 34
There are eight dipswitches on the dryer control. The first six
switches are used to program the amount of additional heat time
given for each coin pulse. The additional drying time is added to
the factory default minimum heat time of one minute. A value of
1 to 63 minutes of additional drying time is available for each
coin slide pulse.
Models Through Serial No. 0908
The last two switches are used to program the amount of addi-
tional cool down time. The additional cool down time is added to
the factory default minimum cool down time of 3 minutes. A val-
ue of 1 to 3 additional minutes is available.
Models Starting Serial No. 0909
The seventh switch is used to program the amount of additional
cool down time. The additional cool down time is added to the
factory default minimum cool down time of 3 minutes. A value
of 3 additional minutes is available.
The eighth switch is used for the cycle reset. If the switch is OFF
(default), the control will save the time left on a cycle in case of a
power failure. If the switch is ON, the control will clear the cycle
and return to Ready Mode if there is a power failure.
All Models
The control is shipped from the factory programmed with 1 mi-
nute of minimum heat time, preset with 41 additional minutes of
drying time (dipswitches 1, 4 and 6 in ON position) and 3 mi-
nutes of minimum cool down time for a total time of 45 minutes
for a coin pulse. Refer to
Table 7
for dipswitch settings.
The control reads the dipswitch settings at power-up. The control
must be powered down to change the dipswitch settings.
To change the heat or cool down time for a coin pulse, the de-
sired dry time dipswitches must be set to ON position. All other
dipswitches must be in OFF position.
NOTE: The control must be powered down for 10 sec-
onds before the dipswitch can be changed.
Models Starting Serial No. 0909
Resetting Cycle Time to Zero
To remove any cycle time that may have accumulated on the con-
trol during setup, the cycle time on the control can be reset to
zero.
To reset the time, unplug the dryer and set dipswitch 8 to ON po-
sition. Restore power to the dryer for 10 seconds and once again
unplug dryer. Set dipswitch 8 to OFF position and restore power
to the dryer.