background image

Programming

Frontload Washer

Refer to Page 7 for Model Identification

FLW88R_SVG

Original Instructions
Keep These Instructions for Future Reference.
CAUTION: Read the instructions before using the machine.

(If this machine changes ownership, this manual must accompany machine.)

www.alliancelaundry.com

Part No. 805407R6

November 2018

Содержание BFNBCASG113TN01

Страница 1: ...ication FLW88R_SVG Original Instructions Keep These Instructions for Future Reference CAUTION Read the instructions before using the machine If this machine changes ownership this manual must accompany machine www alliancelaundry com Part No 805407R6 November 2018 ...

Страница 2: ......

Страница 3: ... manual are not meant to cover all possi ble conditions and situations that may occur It must be understood that common sense caution and care fulness are factors which cannot be built into these washers These factors MUST BE supplied by the per son s installing maintaining or operating the unit Always contact the distributor service agent or the manufacturer about any problems or conditions you d...

Страница 4: ...al Vend Mode 12 Additional Vend Mode 12 Start Mode 12 End of Cycle Mode 12 Door Locking Mode 12 Door Unlocking Mode 12 Cycle Sequence 12 Closing Washer Door 13 Signals 13 Changing Cycles 13 Special Features 14 Programming Control 14 Collecting Audit Information 14 Testing Machine and Control Functions 14 Rapid Advance Feature 14 Copyright 2018 Alliance Laundry Systems LLC All rights reserved No pa...

Страница 5: ...oin 2 Value dEn2 22 Start Pulse Value PLSE 23 Cycle Length CyCL 23 Default Cycle dCyC 23 Card Reader Display Control CArd 23 Audio Signal AUd 24 How to Program the Audio Signal 24 Error Code Programming Err 24 Water Level FLvL 25 Number of Balance Attempts with No Loss of Time bALA 25 OPL Parameters oPL 25 Collecting Audit Information 26 How to Enter Audit Feature 26 Entering the Audit Feature by ...

Страница 6: ...Switch Test d 22 32 External Outputs Test d 23 32 Water Purge Test d 24 32 Water Leak Detection Test d 25 33 Water Level Test d 26 33 DC Bus Voltage Test d 27 33 AC Mains Voltage Test d 28 33 Configuration 1 Display Test d 29 33 Configuration 2 Display Test d 30 36 Configuration 3 Display Test d 31 36 Configuration 4 Display Test d 32 36 Configuration 5 Display Test d 33 37 Factory Test 37 To Ente...

Страница 7: ...W36 HTEBCASP173TW01 SFNBCASG113TW01 STEBXASP434AW01 BTEBXASP173FW28 HTEBCASP175TW01 SFNBCASP113TQ01 STEBXASP434AW12 BTEBXASP433AW01 HTEBDASP283CW01 SFNBCASP113TW01 STEBXASP543DW01 BTEBXASP434AW01 HTEBDASP285CW01 SFNBCASP115TW01 STEBXASP543ZW01 BTEBYASP173TW01 HTEBXASP133DW01 SFNBCRSP113TW01 STEBXASP544DW01 BTGBCASP113TW01 HTEBXASP134DW01 SFNBCRSP113TW02 STEBXASP544ZW01 BTGBLASP303AW01 HTEBXASP134F...

Страница 8: ...SP115TW02 STGBXASP304NW22 HFNBCRSP113TW01 HTGBXASP114FW01 SFNBYASG113TW01 STGBXASP304ZW01 HFNBCRSP115TW01 HTGBXASP123DW01 SFNBYASP113TW01 STGBXASP543DW01 HFNBDASG113CW01 HTGBXASP124DW01 SFNBYASP115TW01 STGBXASP544DW01 HFNBDASG115CW01 HTGBXASP543DW01 SFNBYRSP113TW01 STGBYASP113TW01 HFNBDASP113CW01 HTGBXASP544DW01 SFNBYRSP115TW01 STGBYASP115TW01 HFNBDASP115CW01 HTGBYASP093CW01 STEBCASP173TQ01 TTEBXA...

Страница 9: ...s term refers to the lights next to the keypads and status words of the control FEC Front End Control I O Board Input Output Board OPL On Premises Laundry Power Failure Recovery If a cycle is in progress and the power fails the cycle status is saved in memory When the power recovers the washer will re sume into the previously active cycle if so programmed by the owner The owner may program a speci...

Страница 10: ... the first fill step of the cycle The selected cycle is indicated by the light LED on the pad Pressing the flashing START pad will confirm the selection and the cycle will begin When a card reader is used pressing the START pad will start the cycle and deduct the vend price from the card FLW88R_SVG1 1 3 4 5 6 2 1 LED Light 2 SELECT CYCLE pads 3 Four 7 Segment Digits 4 Display 5 LED Status Lights 6...

Страница 11: ...on of the cycle and will remain lit until the rinse is complete SPIN LED SPIN LED is lit during the Final Spin portion of the cycle DOOR LOCKED LED DOOR LOCKED LED is lit whenever the door is locked The door can t be opened when this LED is lit 7 Segment Digits The 7 SEGMENT DIGITS are used to display the time remain ing in a cycle vend price error messages and descriptive codes During diagnostic ...

Страница 12: ...ressed or a coin card is entered When one of these three options occurs the display will revert back to the ready mode Door Locking Mode The control enters this mode after the Start pad is pressed in Start Mode or Pause Mode to start or resume a machine cycle The control will stay in Door Locking Mode until the loading door is closed and locked The control shows the remaining cycle time and the Do...

Страница 13: ...e a keypad is pressed 3 Signal On Coin Input Card Insertion By default this signal is turned on and will sound for a quarter of a second each time a coin or card is entered 4 Signal for Serial or Network Vending Command By de fault this signal is turned on for a quarter of a second when the control receives a valid serial or network vend command 5 Signal for Start By default this signal is turned ...

Страница 14: ... active cycle or advance into a cycle from the Ready Mode This feature is useful when tests must be performed immediately on a ma chine currently in an active cycle In this case the user can quick ly advance through the cycle to the Ready Mode At this point the user can perform the required tests and then return the ma chine to the active cycle Clearing the Vend Feature This feature allows the use...

Страница 15: ...nd closing the service door or unplugging the bul let connector the programmer has 4 25 minutes to begin pro gramming If a keypad has not been pressed in that time the con trol will revert back to the Ready Mode Refer to Figure 2 The service door is located in the control panel on the Stacked Washer and Dryers and Front Control Washers On Rear Control Washers the service door is located on the top...

Страница 16: ...ve the screws from the bottom of the control panel that attach the control panel to the machine NOTE When reinstalling the control panel be sure to align the control panel s tabs with the machine s tabs Stack Units 1 Remove the screws from the bottom of the dryer front panel 2 Remove the screws that attach the bottom of the dryer base to the frontload washer s control panel 3 To gain access to the...

Страница 17: ...FLW2384N_SVG SWD990N_SVG Figure 3 Opening the Service Door Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 17 Part No 805407R6 ...

Страница 18: ... pressing and holding the PERM PRESS WARM key pad with one hand press the NORMAL HOT keypad with the other hand 5 The display will show rAPd 6 Press the NORMAL WARM or the DELICATES COLD keypad to scroll through the options until the desired op tion appears in the display 7 Press the START enter keypad NOTE After entering Manual Mode if no keypads are pressed for 4 25 minutes the control will retu...

Страница 19: ...ance cycle and to advance through cycle steps Press the START keypad to enter Manual Programming Refer to Manual Programming flowchart CyC Total machine cycles Coi1 Total coins 1 PLSE Total start pulses Coi2 Total coins 2 Press the START keypad to enter Manual Reset Mode Press the START keypad to enter Diagnostic Tests Refer to Diagnostic Tests flowchart FLW145R_SVG Press the START enter keypad to...

Страница 20: ...s in the Option Display column of the Programmable Options List are what will be shown in the display when that option is selected Programmable Options Available Option Number Option Display Description Factory Default Value Range 1 AtS Vend Price 200 0 65 535 2 dEn1 Coin 1 Value 25 1 65 535 3 dEn2 Coin 2 Value 100 1 65 535 4 PLSE Start Pulse Value 25 1 65 535 5 CyCL Cycle Length 3 3 5 6 dCyC Defa...

Страница 21: ...RM PRESS WARM keypad FLW119R_SVG Press the NORMAL WARM or the DELICATES COLD keypad to scroll through the programmable options CArd Card Reader Display Control Err Errors SUd1 Suds Removal Routine Display bALA Balance Attempts oPL OPL Mode SUd2 Suds Removal Routines Allowed Per Cycle SUd3 Suds Removal Routine Extra Time FLvL Water Level Figure 5 Programming Control Copyright Alliance Laundry Syste...

Страница 22: ...ue of the fifth digit NOTE The coin value can be set from 1 to 65 535 The factory default setting is 25 6 Press the START enter keypad to enter the fifth digit and display remaining four digits The active digit will flash one second on and one second off NOTE To go back to the current programmable op tion without changing the value press the PERM PRESS WARM keypad 7 Press the NORMAL WARM or the DE...

Страница 23: ... Mode 2 Press the NORMAL WARM or the DELICATES COLD keypad until Prog appears in the display Press the START enter keypad and AtS will appear in the display 3 Press the NORMAL WARM or the DELICATES COLD keypad to scroll through the programmable options until CyCL appears in the display 4 When CyCL appears in the display press the START enter keypad NOTE To go back to the current programmable op ti...

Страница 24: ... satisfied How to Program the Audio Signal 1 Control must be in Manual Mode Refer to How to Enter the Manual Mode 2 Press the NORMAL WARM or the DELICATES COLD keypad until Prog appears in the display Press the START enter keypad and AtS will appear in the display 3 Press the NORMAL WARM or the DELICATES COLD keypad to scroll through the programmable options until AUd appears in the display 4 When...

Страница 25: ...with No Loss of Time bALA This option allows the owner to program the machine s number of balance attempts with no loss of time If the machine needs to re balance for any reason time will pause for additional balance at tempts when this parameter is greater than 1 A value of 1 allows for the normal allocated time Further attempts beyond the pro grammed value will not pause cycle time This may resu...

Страница 26: ...e START enter keypad again to view the last four digits of the number NOTE The display can show up to 4 digits at one time Audit counts 10 000 or higher are separated in to two 4 digit segments Each time the START en ter keypad is pressed in step 2 the display will show the next 4 digit segment in the audit value If the value is 9 999 or less only one 4 digit segment will be shown For Example In t...

Страница 27: ...r to How to En ter the Manual Mode 2 Press the NORMAL WARM or the DELICATES COLD keypad until rSEt appears in the display 3 Press the START enter keypad no will appear in the dis play 4 Press the NORMAL WARM or the DELICATES COLD keypad to change the value to yes 5 Press the START enter keypad to reset the control to the fac tory default settings Manual Reset Copyright Alliance Laundry Systems LLC...

Страница 28: ... be in Manual Mode Refer to How to Enter the Manual Mode 2 Press the NORMAL WARM or the DELICATES COLD keypad to scroll through the programmable options until dIAg appears in the display 3 Press the START enter keypad Display will change to d 1 indicating the control software version number test 4 Press the NORMAL WARM or the DELICATES COLD keypad to scroll through the diagnostic test options How ...

Страница 29: ...Urg or FLSH d 25 Water Leak Detection Test PASS E Ld E LF or Ld CLoS door d 26 Water Level Test L or L d 27 DC Bus Voltage Test d 28 AC Mains Voltage Test d 29 Machine Configuration 1 Display Test A d 30 Machine Configuration 2 Display Test b d 31 Machine Configuration 3 Display Test C d 32 Machine Configuration 4 Display Test d d 33 Machine Configuration 5 Display Test E Table 4 Testing Machine a...

Страница 30: ...6 Door Lock Switch Input Test d 18 Show Drain Time Test d 22 Out of Balance Switch Input Test d 23 External Output Test d 24 Water Purge Test d 26 Water Level Test d 27 DC Bus Voltage Test d 29 Machine Configuration 1 Display Test d 28 AC Mains Voltage Test d 25 Water Leak Detection Test d 30 Machine Configuration 2 Display Test d 31 Machine Configuration 3 Display Test d 32 Machine Configuration ...

Страница 31: ... Mode Coin Vault Opening Test d 9 This option tests the coin vault switch To start test the control must be in the Testing Mode Refer to How to Enter Testing Fea ture at the beginning of this section To enter press the START enter keypad The display will show v oP when the coin vault switch is open and v CL when the coin vault switch is closed The coin vault switch has to be closed for at least on...

Страница 32: ...in time This average will be calculated by taking the average of the last 10 drain times To start test control must be in the Testing Mode Refer to How to Enter Testing Feature at the beginning of this section To enter press the START enter keypad The display will show dXXX The XXX will be the average fill time in seconds To exit the Show Drain Time Test press the PERM PRESS WARM keypad The contro...

Страница 33: ...control will return to the Testing Mode Water Level Test d 26 This test displays the water level as determined by the water level sensor To start test control must be in the Testing Mode Refer to How to Enter Testing Feature at the beginning of this section To enter press the START enter keypad The display will show L XXX where XXX is the water level in 0 1 inch precision where a value of 05 equal...

Страница 34: ...ES NO YES YES 12 NO NO YES YES NO NO 13 NO NO YES YES NO YES 14 NO NO YES YES YES NO 15 NO NO YES YES YES YES 16 NO YES NO NO NO NO 17 NO YES NO NO NO YES 18 NO YES NO NO YES NO 19 NO YES NO NO YES YES 20 NO YES NO YES NO NO 21 NO YES NO YES NO YES 22 NO YES NO YES YES NO 23 NO YES NO YES YES YES 24 NO YES YES NO NO NO 25 NO YES YES NO NO YES 26 NO YES YES NO YES NO 27 NO YES YES NO YES YES 28 NO ...

Страница 35: ...O YES NO YES NO 43 YES NO YES NO YES YES 44 YES NO YES YES NO NO 45 YES NO YES YES NO YES 46 YES NO YES YES YES NO 47 YES NO YES YES YES YES 48 YES YES NO NO NO NO 49 YES YES NO NO NO YES 50 YES YES NO NO YES NO 51 YES YES NO NO YES YES 52 YES YES NO YES NO NO 53 YES YES NO YES NO YES 54 YES YES NO YES YES NO 55 YES YES NO YES YES YES 56 YES YES YES NO NO NO 57 YES YES YES NO NO YES 58 YES YES YES...

Страница 36: ...120 Volt If supply voltage is 200 240 Volt per phase the voltage configu ration should be 240 Volt To exit Machine Configuration 4 Display Test press the PERM PRESS WARM keypad The control will return to the Testing Mode Each column in the table below contains a unique combination of the words ON and OFF that indicates if that column s dips witch is set on or off when the value is displayed Config...

Страница 37: ...ON ON OFF OFF 197 ON ON ON OFF ON 198 ON ON ON ON OFF 199 ON ON ON ON ON Table 6 Configuration 5 Display Test d 33 This option is not used on this model Factory Test To Enter Factory Test 1 Be certain control is in Ready Mode or Start Mode and access panel or coin vault is open 2 While pressing and holding the NORMAL COLD modifier keypad with one hand press the PERM PRESS WARM key pad with the oth...

Страница 38: ...til the Start keypad is pressed v oP or v CL Coin Vault Test v oP is displayed when coin vault switch is open v CL is displayed when coin vault switch is closed S oP or S CL Service Door Switch Test S oP is displayed when service door switch is open S CL is displayed when service door switch is closed CXCX Coin Drop Test X is the number of coins entered Coin drop 1 is shown on the left of the dis ...

Страница 39: ...nput The display shows PrSt and all water valves turn on When the Water Fill Lev el is satisfied the water valves are turned off If the Start key is pressed and the Water Fill level is not satisfied the con trol will not advance to the next cycle step oFLo Overflow Test All water and dispenser valves are turned on When the overflow level is reached the water valves are turned off If the START ente...

Страница 40: ...d press unlocks the door Pd Power Down This is the final step of Factory Test The control will display Pd to signify that factory test has been completed and that the user can safely unplug the machine Cycling power to the machine is the only way to resume normal operation and the control will stay in this state indefinitely until that time Table 7 Testing Machine and Electronic Control Functions ...

Страница 41: ...ower down power up and try again If error persists replace control or card reader EC19 No Card Reader Communication Communication failure Power down power up and try again If error persists replace control or card reader Right most deci mal point Lit Water Leak Detec tion Error or Slow Drain Detection Error Water leak test has detected a water leak during a cycle or slow drain is detected in the d...

Страница 42: ... and remove ob structions If error persists tampering may have occured Evaluate security proce dures E id Board ID Incorrect replacement control Replace user control or output board with the correct part E dS Brownout Voltage Configuration Unexpected supply voltage Check the harness connections between the user control and the output board If the user control was replaced set dip switch 1 to the s...

Страница 43: ...he empty level after attempting to drain for the programmable time default 15 minutes In the event of a drain error the control will turn off all outputs and turn on the Machine Error Tone for 15 seconds E Sd Slow Drain Error If a slow drain is detected in the Drain step of a running cycle the machine control will light the right most decimal point The decimal point will remain illuminated af ter ...

Страница 44: ... or a Clear Fatal Error Network command must be send E bb Broken Belt Error If a broken belt is ever detected by the control the control will show error this error code To clear this error one of the following must occur the machine must be pow ered down the Clear Fatal Error Keys must be pressed or a Clear Fatal Error Network command must be sent E LF Water Leak Fill Error If the water level has ...

Страница 45: ...se times are very short and programmable Unpower to clear error Check for lint build up on heat sink on drive board Replace drive board if error persists E d 29 Motor Not Con nected Error The motor or one of its electrical phases is not connected Check that the harness from the motor to the drive board is fully plugged in on both ends and that there is no dam age to the motor harness Make sure to ...

Страница 46: ...clear error Replace drive board if error persists E d 55 Fatal NTC Short Error Check heater thermistor and thermistor wiring for damage Unpower to clear error Replace drive board if error persists E d 56 Fatal NTC Open Error Check heater thermistor and thermistor wiring for damage Unpower to clear error Replace drive board if error persists E d 63 Fatal IPM Temper ature Short Error Hardware failur...

Страница 47: ...Mode 2 Press the NORMAL WARM or the DELICATES COLD keypad to scroll through the programmable options until rAPd appears in the display 3 Press the START enter keypad The display will show PUSH then Strt followed by the cycle time and the START enter keypad LED will flash 4 Press the START enter keypad to start cycle or if already in an active cycle pressing START enter keypad will advance to the n...

Страница 48: ...ss than 5 seconds and the door is locked the cycle will resume without requiring the user to press the START enter keypad to restart If the power failure lasted longer than 5 seconds the control will require the user to press the START enter keypad to restart Power Fail Recovery Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 48 Part No 805407R6 ...

Страница 49: ...ns feature allows the washer con trol to communicate with the card reader The washer control can be programmed for a limited number of options and have its data read without using the keypad Communications Mode Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 49 Part No 805407R6 ...

Страница 50: ... Extract 2 00 Wash Using wetting fill 7 Fill 2 30 8 Supply Detergent Bleach ES1 ES2 0 30 9 Agitate Normal 3 00 Perm Press 2 30 Delicate 2 00 10 Cooldown 11 Extract Normal Perm Press 4 20 Delicate 4 05 Rinse 1 12 Fill 2 00 13 Agitate 0 35 14 Extract Normal Perm Press 4 20 Delicate 4 05 Rinse 2 Active with Cycle Length Parameter set to 4 or 5 15 Fill 2 00 16 Agitate 0 35 17 Extract Normal Perm Press...

Страница 51: ...ly Softener ES3 ES4 0 30 23 Agitate 0 35 Final Extract 25 Extract Normal 9 50 Perm Press 8 20 Delicate 7 20 Shakeout 25 Agitate 0 40 Total Time Normal 30 00 Perm Press 28 00 Delicate 26 00 Default Cycle Time Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 51 Part No 805407R6 ...