Factory Test Quick Reference Chart
Display
Test Mode
Comments
8888
Display Test
All LEDs and display segments will
light.
droP
or
drCL
Door Switch Test
droP
is displayed when loading door is
open.
drCL
is displayed when loading
door is closed.
dbXX
Driver Type and Driver Version Number
Driver board version display when XX is
the driver software version number.
drLo
or
drUL
Door Lock Test
When step is entered, control will lock
door and will then check to make sure
door is locked. drLo is displayed if door
is locked. drUL is displayed if door is un-
locked.
CLdE
Cold/Detergent Fill
Cold Water Fill valve and Detergent/
Bleach valve are turned on.
HoSF
Hot/Softener Fill
Hot Water Fill valve and Softener valve
are turned on.
PrSr
Pressure Sensor Fill
This step checks the water level input.
The display shows
PrSt
, and all water
valves turn on. When the Water Fill Lev-
el is satisfied, the water valves are turned
off. If the Start key is pressed and the
Water Fill level is not satisfied, the con-
trol will not advance to the next cycle
step.
oFLo
Overflow Test
All water and dispenser valves are turned
on. When the overflow level is reached
the water valves are turned off. If the
START (enter) key is pressed and the
Water Fill level is not satisfied, the con-
trol will not advance to the next cycle
step.
LoAg
Low Agitate
Machine enters low agitate.
rEAg
Regular Agitate
Machine enters regular agitate.
PUNP
or
drAi
Pump/Gravity Drain Test
Pump is turned on or gravity drain is
opened. The control will not advance to
next step until drum is empty.
RPM speed displayed
XXXX
Spin Test
Machine will attempt to spin up to 1200
RPMs.
Table 7
continues...
Testing Machine and Electronic Control Functions
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
39
Part No. 805407R6
Содержание BFNBCASG113TN01