Communicate with Devices on a ControlNet Network
Appendix B
8.
Click OK.
IMPORTANT
The virtual backplane driver must be installed via RSLinx software
before you can download a project to the SoftLogix controller. Even if
you plan to remotely program the controller over a ControlNet or
Ethernet network, you must add the virtual backplane driver via
RSLinx software. If you do not, persistent storage will not function and
when you restart the computer, the controller will come up with
cleared memory (the program will not get reloaded).