![Allen-Bradley micrologix 1500 Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/allen-bradley/micrologix-1500/micrologix-1500_user-manual_2900209063.webp)
Publication 1764-UM001A-US-P
Communication Connections
4-11
1761-CBL-AM00
1761-CBL-HM02
Cable
Length
Connections from
to AIC+ External Power
Supply Required
(1)
Power Selection
Switch Setting
1761-CBL-AM00
(2)
1761-CBL-HM02
45cm (17.7 in)
2m (6.5 ft)
MicroLogix 1000 or 1500
port 2
no
cable
to port 2 on another AIC+
port 2
yes
external
(1) External power supply required unless the AIC+ is powered by the device connected to port 2, then the selection switch should be set to
cable
.
(2) Series C or higher cables are required.
1761-CBL-AC00
1747-CP3
Cable
Length
Connections from
to AIC+
External Power
Supply Required
(1)
Power Selection
Switch Setting
1747-CP3
1761-CBL-AC00
(2)
3m (9.8 ft)
45cm (17.7 in)
1764-LRP processor, channel 1
port 1
yes
external
SLC 5/03 or SLC 5/04 processor, channel 0
port 1
yes
external
PC COM port
port 1
yes
external
PanelView 550 through NULL modem adapter
port 1
yes
external
DTAM Plus / DTAM Micro™
port 1
yes
external
Port 1 on another AIC+
port 1
yes
external
(1) External power supply required unless the AIC+ is powered by the device connected to port 2, then the selection switch should be set to
cable
.
(2) Series C or higher cables are required.
user supplied cable
Cable
Length
Connections from
to
AIC+
External Power Supply
Required
(1)
Power Selection
Switch Setting
straight 9-25 pin —
modem or other communication device
port 1
yes
external
(1) External power supply required unless the AIC+ is powered by the device connected to port 2, then the selection switch should be set to
cable
.
1761-CBL-AS03
1761-CBL-AS09
Cable
Length
Connections from
to AIC+
External Power
Supply
Required
(1)
Power Selection
Switch Setting
1761-CBL-AS03
1761-CBL-AS09
3m (9.8 ft)
9.5m (31.17 ft)
SLC 500 Fixed,
SLC 5/01, SLC 5/02, and SLC 5/03 processors
port 3
yes
external
PanelView 550 RJ45 port
port 3
yes
external
(1) External power supply required unless the AIC+ is powered by the device connected to port 2, then the selection switch should be set to
cable
.
Содержание micrologix 1500
Страница 1: ...MicroLogix 1500 Programmable Controllers Bulletin 1764 User Manual AB Spares...
Страница 6: ...Publication 1762 RM001A US P Preface P 4...
Страница 52: ...Publication 1764 UM001A US P 3 16 Wiring Your Controller...
Страница 78: ...Publication 1764 UM001A US P 5 10 Using Trim Pots and the Data Access Tool DAT...
Страница 96: ...Publication 1764 UM001A US P B 6 Replacement Parts...
Страница 102: ...Publication 1764 UM001A US P C 6 Troubleshooting Your System...
Страница 132: ...Publication 1764 UM001A US P F 10 System Loading and Heat Dissipation...
Страница 147: ...AB Spares...
Страница 149: ...AB Spares...