QRUPDOO\ FORVHG
Contacts on a relay or switch that are closed when the relay is de-energized or
deactivated. They are open when the relay is energized or the switch is activated.
QRUPDOO\ RSHQ
Contacts on a relay or switch that are open when the relay is de-energized or the
switch is deactivated. They are closed when the relay is energized or the switch is
activated.
RIIGHOD\ WLPH
The OFF delay time is a measure of the time required for the controller logic to
recognize that a signal has been removed from the input terminal of the controller.
The time is determined by circuit component delays and by any applied filter.
RIIOLQH
When a device is not scanning/controlling or when a programming device is not
communicating with the controller.
RIIVHW
A continuous deviation of a controlled variable from a fixed point.
RIIVWDWH OHDNDJH FXUUHQW
When a mechanical switch is opened (off-state), no current flows through the
switch. Semiconductor switches and transient suppression components which are
sometimes used to protect switches, have a small current flow when they are in the
off state. This current is referred to as the off-state leakage current. To ensure
reliable operation, the off-state leakage current rating must be less than the
minimum operating current rating of the device that is connected.
RQGHOD\ WLPH
The ON delay time is a measure of the time required for the controller logic to
recognize that a signal has been presented at the input terminal of the controller.
RQH VKRW
A programming technique that sets a bit ON or OFF for one program scan.
RQOLQH
When a device is scanning/controlling or when a programming device is
communicating with the controller.
RSHUDWLQJ YROWDJH
For inputs, the voltage range needed for the input to be in the On state. For
outputs, the allowable range of user-supplied voltage.
RXWSXW GHYLFH
A device, such as a pilot light or a motor starter coil, that receives a signal or
command from the controller.
Содержание micrologix 1500
Страница 1: ...MicroLogix 1500 Programmable Controllers Bulletin 1764 User Manual AB Spares...
Страница 6: ...Publication 1762 RM001A US P Preface P 4...
Страница 52: ...Publication 1764 UM001A US P 3 16 Wiring Your Controller...
Страница 78: ...Publication 1764 UM001A US P 5 10 Using Trim Pots and the Data Access Tool DAT...
Страница 96: ...Publication 1764 UM001A US P B 6 Replacement Parts...
Страница 102: ...Publication 1764 UM001A US P C 6 Troubleshooting Your System...
Страница 132: ...Publication 1764 UM001A US P F 10 System Loading and Heat Dissipation...
Страница 147: ...AB Spares...
Страница 149: ...AB Spares...