![Allen-Bradley EtherNet/IP 842E-MIP10BA Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/allen-bradley/ethernet-ip-842e-mip10ba/ethernet-ip-842e-mip10ba_user-manual_2900505026.webp)
26
Rockwell Automation Publication 842E-UM001C-EN-P - September 2016
Chapter 3
EtherNet/IP Overview
See Appendix B on page
75
for an example of how to use the position sensor
object to create an explicit message in RSLogix 5000®.
Identity Object
The device information and device parameters are opened via the instances.
Figure 14 - Connections for the Identity Object
Service Code
Service
Description
01h
Get_Attribute_All
Returns the values of all attributes
0Eh
Get_Attribute_Single
Returns the values of one attribute
Table 2 - Class Services of the Identity Object
Attribute ID Access
Description
Data Type
Default Value
1
Get
Object revision index
UINT
0001h
2
Get
Highest instance number within the class
UINT
0001h
3
Get
Number of object instances in this class
UINT
0001h
4
Get
Optional attribute list
STRUCT
—
6
Get
Highest existing class attribute ID
UINT
0007h
7
Get
Highest implemented instance attribute
UINT
0075h
Table 3 - Class Attributes of the Identity Object
IMPORTANT
Class attribute 5 is not implemented.
23h Position Sensor
02h Message
Router
01h Identity
F6h
06h Connection Manager
04h Assembly
F4h
F5h
Network
48h QoS
47h DLR
Содержание EtherNet/IP 842E-MIP10BA
Страница 6: ...6 Rockwell Automation Publication 842E UM001C EN P September 2016 Table of Contents Notes...
Страница 8: ...8 Rockwell Automation Publication 842E UM001C EN P September 2016 Preface Notes...
Страница 44: ...44 Rockwell Automation Publication 842E UM001C EN P September 2016 Chapter 4 Installation Notes...
Страница 95: ...Rockwell Automation Publication 842E UM001C EN P September 2016 95 RSLogix 5000 Sample Code Appendix B Notes...