Rockwell Automation Publication 842E-UM001C-EN-P - September 2016
39
Chapter
4
Installation
Mechanical
This chapter describes how to install the 842E EtherNet/IP Encoder.
Also refer to the installation sheet provided in the box,
Publication No.
100000169360
.
Shaft Rotation Direction
When you view the encoder from the shaft side, the shaft rotation is clockwise
(CW) or counterclockwise (CCW), as shown.
Figure 1
Mounting with a Solid Shaft
1. Be sure to select the proper size flexible coupling clamp to mate to the
encoder shaft, for example, 845–FC–*–*. See our website at
http://
ab.rockwellautomation.com/Motion-Control/Encoders
for encoder
accessories.
2. To determine the encoder mounting hole locations, use the dimension
drawings in the installation instructions (see “
Related Documentation”
on page
7
).
3. Slide the flexible coupling onto the shaft, but do not tighten the set
screws.
ATTENTION:
Do not rigidly connect the encoder shaft to the machine. A rigid
connection causes premature failure of the encoder or machine bearings.
Always use a flexible coupling.
Содержание EtherNet/IP 842E-MIP10BA
Страница 6: ...6 Rockwell Automation Publication 842E UM001C EN P September 2016 Table of Contents Notes...
Страница 8: ...8 Rockwell Automation Publication 842E UM001C EN P September 2016 Preface Notes...
Страница 44: ...44 Rockwell Automation Publication 842E UM001C EN P September 2016 Chapter 4 Installation Notes...
Страница 95: ...Rockwell Automation Publication 842E UM001C EN P September 2016 95 RSLogix 5000 Sample Code Appendix B Notes...