Rockwell Automation Publication 842E-UM001C-EN-P - September 2016
69
Diagnostics and Troubleshooting
Chapter 7
Errors
Bit
Description
Description
FALSE (0)
(44)
TRUE (1)
(44)
0
Position ERROR
Position error
Ok
ERROR
1
Diagnostic ERROR
Diagnostic error
Ok
ERROR
2…11
Reserved by CIP
–
–
–
12
Vendor: checksum ERROR
Checksum error
Ok
ERROR
13
Vendor: startup ERROR
Startup error
Ok
ERROR
14…15
Vendor specific
–
–
–
Table 2 - Supported Alarms (Attribute 44+45)
Fault
Header
[byte]
Bit
Name
Description
0
0
Over temperature controller
Temperature value of the microcontroller is
out of range
1
Over temperature sensor
Temperature value of the sensor is out of
range
2
Light control reserve
Indicator current is not correct
3
Voltage detection
Over/Under voltage detection (fall below/
exceeded the limit)
4
Frequency exceeded.
Speed too high (limit exceeded)
5
Velocity exceeded
Minimum/maximum velocity setpoint
reached
6
Acceleration exceeded
Minimum/maximum acceleration setpoint
reached
7
Position limits exceeded
Minimum/maximum position setpoint
reached
1
8
Position error
Amplitude error single
9
Position error
Amplitude error multiple
10
Position error
Vector length single
Vector length (Sin
2
+ cos
2
)
11
Position error
Vector length multiple
Vector length (Sin
2
+ cos
2
)
12…14 Reserved
15
Reserved
Table 3 - Sensor Error Table
Содержание EtherNet/IP 842E-MIP10BA
Страница 6: ...6 Rockwell Automation Publication 842E UM001C EN P September 2016 Table of Contents Notes...
Страница 8: ...8 Rockwell Automation Publication 842E UM001C EN P September 2016 Preface Notes...
Страница 44: ...44 Rockwell Automation Publication 842E UM001C EN P September 2016 Chapter 4 Installation Notes...
Страница 95: ...Rockwell Automation Publication 842E UM001C EN P September 2016 95 RSLogix 5000 Sample Code Appendix B Notes...