Pin Assignments
Preset Push Button
To preset the position of the encoder, remove the screw cover from the back of
the encoder and briefly press the Preset button inside (see figure on page
41
and “Preset Function” on
page 62
).
Network Address Switches
You can use the three Network Address switches to set the IP address of the
encoder (see
Figure 3 on page 47
and “Setting the IP address” on
page 45
).
Pin
Signal
Mating Cable
Wire Color
Function
1
Versus
Brown
Supply voltage 10…30V DC
2
White
Do not use
3
GND
Blue
0V DC (ground)
4
Black
Do not use
Table 1 - Voltage Supply
Pin
Signal
Mating Cable
Wire Color
Function
1
TxD+
White orange
Ethernet
2
RxD+
White green
Ethernet
3
TxD–
Orange
Ethernet
4
RxD–
Green
Ethernet
Table 2 - Ethernet Link Connections – Link 1 and Link 2
ATTENTION:
Pressing the preset push button results in a change of position
reading.
The change in position causes unexpected motion, which could result in
personal injury or damage to the product or equipment.
IMPORTANT
Press the preset button briefly, no longer than one second.
Содержание EtherNet/IP 842E-MIP10BA
Страница 6: ...6 Rockwell Automation Publication 842E UM001C EN P September 2016 Table of Contents Notes...
Страница 8: ...8 Rockwell Automation Publication 842E UM001C EN P September 2016 Preface Notes...
Страница 44: ...44 Rockwell Automation Publication 842E UM001C EN P September 2016 Chapter 4 Installation Notes...
Страница 95: ...Rockwell Automation Publication 842E UM001C EN P September 2016 95 RSLogix 5000 Sample Code Appendix B Notes...