Communicate over Networks
ControlLogix DH-485 Network Communication Overview
On the DH-485 network, the ControlLogix controller can send and
receive messages to and from other controllers.
For the controller to operate on a DH-485 network, you need a
1761-NET-AIC interface converter for each controller you want to put
on the DH-485 network.
You can have two controllers for each 1761-NET-AIC converter, but
you need a separate cable for each controller. Connect the serial port
of the controller to either port 1 or port 2 of the 1761-NET-AIC
converter. Use the RS-485 port to connect the converter to the DH-485
network.
Cable Selection
IMPORTANT
A DH-485 network consists of multiple cable segments. Limit
the total length of all the segments to 1219 m (4000 ft).
Connection
Required Cable
Port 1
DB-9 RS-232, DTE connection
1747-CP3
or
1761-CBL-AC00
Port 2
Mini-DIN 8 RS-232 connection
1761-CBL-AP00
or
1761-CBL-PM02
Connection from ControlLogix
Controller to Port 1 or Port 2
ControlLogix Controller
SLC 5/03 Controller
1761-NET-AIC+
Converter
1747-AIC
Programmable
Controller Isolated
Link Coupler
DH-485 Network
Содержание controllogix 1756-L55M12
Страница 4: ...Publication 1756 UM001G EN P January 2007 Summary of Changes 4 Notes...
Страница 10: ...Publication 1756 UM001G EN P January 2007 10 Notes...
Страница 20: ...Publication 1756 UM001G EN P January 2007 20 Directly Connect to the Controller via the Serial Port Notes...
Страница 66: ...Publication 1756 UM001G EN P January 2007 66 Place Configure and Monitor I O Modules Notes...
Страница 82: ...Publication 1756 UM001G EN P January 2007 82 Develop Applications Notes...
Страница 122: ...Publication 1756 UM001G EN P January 2007 122 Maintain Nonvolatile Memory Notes...
Страница 130: ...Publication 1756 UM001G EN P January 2007 130 Maintain the Battery Notes...
Страница 134: ...Publication 1756 UM001G EN P January 2007 134 LED Indicators Notes...