Bulletin 290E/291E/294E Programmable Parameters
Chapter
4
ATTENTION:
•
If a hazard of injury due to movement of equipment or material exists, an
auxiliary mechanical braking device must be used.
•
This feature should not be used with synchronous or permanent magnet
motors. Motors may be demagnetized during braking.
ReverseDisable
Enables/disables the function that allows
the direction of the motor rotation to be
changed.
0 = Enabled
1 = Disabled
Parameter Number
77
Related Parameters
—
Access Rule
GET/SET
Data Type
UINT
Group
Advanced Config.
Units
—
Minimum Value
0
Maximum Value
1
Default Value
0
FlyingStartEn
Sets the condition that allows the drive
to reconnect to a spinning motor
at actual RPM.
0 = Disabled
1 = Enabled
Parameter Number
78
Access Rule
GET/SET
Data Type
UINT
Group
Advanced Config.
Units
—
Minimum Value
0
Maximum Value
1
Default Value
0
Time
[DC Brake Level]
[DC Brake Time]
Stop Command
Speed
Voltage
Volts Speed
[DC Brake Level]
[DC Brake Time]
Time
Voltage
Speed
Stop Command
Volts Speed
DC Injection Braking Mode
Ramp-to-Stop Mode
}
}
}
}
Stop drive before changing this
parameter.
O
Содержание ArmorStart 290E
Страница 1: ...ArmorStart LT Distributed Motor Controller Catalog Numbers 290E 291E 294E User Manual ...
Страница 8: ...8 RockwellAutomationPublication290E UM001B EN P June2012 Summary of Changes Notes ...
Страница 66: ...66 RockwellAutomationPublication290E UM001B EN P June2012 Chapter 2 Installation and Wiring Notes ...
Страница 98: ...98 RockwellAutomationPublication290E UM001B EN P June2012 Chapter 3 Product Commissioning Notes ...
Страница 228: ...228 RockwellAutomationPublication290E UM001B EN P June2012 Appendix B CIP Information Notes ...
Страница 251: ......