Rockwell Automation Publication 8720MC-RM001K-EN-P - September 2018
49
Connect the 8720MC-RPS Unit
Chapter 5
Typical Input Power Diagrams
These example diagrams include single unit, two parallel unit, and three
parallel unit diagrams for 8720MC-RPS065 and 8720MC-RPS190
regenerative power supplies.
Figure 22 - 8720MC-RPS065 (single unit) Input Power Wiring
380…506V AC
Three-phase Input
L1
L2
L3
L1_AUX
L2_AUX
L3_AUX
PR1
PR2
PR3
MC1
MC2
P
N
G
Circuit Protection
MC
RST
PWR
0V
24V
COM
BDSR
MC
Varistor
Harmonic
Filter
EMC
Line Filter
Single-phase
Line Filter
MC
E
Main Magnetic
Contactor (MC)
100 to 115 VAC
or
200 to 230 VAC
Termina Block for
Sequence Signals (TB3)
Run On/Off
8720MC-RPS065 Unit
Terminal Block for Main
Power Supply (TB1)
Termina Block for
Control Power (TB2)
IP
RDY
FR
FR
PIFS
CN2
Terminals
P and N of
Load Equipment
PIFS
CN3
Line
Reactor
(CB)
Note 4
Refer to table on
for note information.
Note 6
Note 6
Note 9, 10, 11
Note 13
Note 12
Note 7
Note 1
Note 3