- 11 -
INSTALLATION
REMOTE OPENING
DOOR STATUS SIGNAL
The Door Status signal is available only when the lock is in
AUTOMATIC MODE
.
Contact open (no signal):
The door is locked and the second
throw of the deadbolts is engaged
Contact closed (signal):
The door is open and/or the
deadbolts are retracted
CONNECTING A REMOTE CONTACT AND THE DOOR STATUS DEVICE
V
5-24 V
AC/DC
C3
C1 Door Status
C2 Battery holder
C7 Power supply
C5 BLE module
C4 CISA MyEVO keypad/RFID
C6 CISA MyEVO button
C3
Remote contact
Door Status signal
T min 100 mS
T max 2 S
Example of button or relay connection
for remote opening.
Light bulb
V
C3
max 60V
max 100 mA
C1 Door Status
C2 Battery holder
C7 Power supply
C5 BLE module
C4 CISA MyEVO keypad/RFID
C6 CISA MyEVO button
C3
Remote contact
Door Status signal
Lampadina
V
C3
C1 Door Status
C2 Battery holder
C7 Power supply
C5 BLE module
C4 CISA MyEVO keypad/RFID
C6 CISA MyEVO button
C3
Remote contact
Door Status signal
max 60V
max 100 mA
N.B.: in SEMI-AUTOMATIC
MODE only, the lock can be
locked, closing the circuit for 3
- 5 seconds
Example of connection of
light bulb