Key Free Touchscreen Deadbolt with Z-Wave Plus

Installation and Programming Instructions

x4

x2 Silver

x3

#8-32 x 5/16"

Machine screws

#7 wood & #8-32

machine x 20mm

Combination screws

M6x55mm

PPHMS
(2-1/4" )

OR

x2 Black

M6x44mm

PPHMS

(Standard 1-3/4"  - 2" )

OR

x2 Gold

M6x36mm

PPHMS
(1-3/8" )

Before you begin

for step-by-step installation

instructions & to register

your product

DOWNLOAD

THE BILT APP

Содержание Real Living YRD156

Страница 1: ...ouchscreen Deadbolt with Z Wave Plus Installation and Programming Instructions x4 x2 Silver x3 8 32 x 5 16 Machine screws 7 wood 8 32 machine x 20mm Combination screws M6x55mm PPHMS 2 1 4 OR x2 Black...

Страница 2: ...P N Rev A AYRD 156 INST FUL 2 Preparing Door and Touchscreen Escutcheon Cup must be removed from escutcheon if bore hole is less than 2 1 8 2 1 8 Application 2 1 8 Application...

Страница 3: ...A AYRD 156 INST FUL 3 x4 1 Installing Latch Strike Plate Rotate 2 3 8 position 2 3 4 position O optional Bolt must be in retracted unlocked position UP arrow must be facing upwards default 2 3 8 2 3...

Страница 4: ...v A AYRD 156 INST FUL 4 2 Installing Touchscreen Escutcheon Outside of Door Ensure cable is routed under the deadbolt If bore hole is less than 2 1 8 remove cup by gently compressing two tabs while pu...

Страница 5: ...P N Rev A AYRD 156 INST FUL 5 x2 3 Installing Interior Mounting Plate Choose through bolt appropriate for your door thickness...

Страница 6: ...6 4 Attaching the Cable Assembly P N Rev A AYRD 156 INST FUL...

Страница 7: ...P N Rev A AYRD 156 INST FUL 7 x3 5 Installing Interior Escutcheon Thumbturn should be in vertical position...

Страница 8: ...P N Rev A AYRD 156 INST FUL 8 Testing Operation Deadbolt should extend and retract smoothly If not go back to step 2 Bolt must be in retracted unlocked position before installing AA batteries...

Страница 9: ...UL 9 Initial Programming Press Enter new Master PIN code 4 8 digits Press to complete Lock will not operate until gear is pressed and Master PIN code is set After entering the Master PIN code press an...

Страница 10: ...YRD 156 INST FUL 10 6 Installing Cover Congratulations you ve installed the Yale Real Living YRD156 Key Free Touchscreen Deadbolt with Z Wave Plus Continue with Programming Instructions to customize y...

Страница 11: ...hanges or modifications to this device not expressly approved by ASSA ABLOY Residential Group could void the user s authority to operate the equipment Low Battery Warning Flashes RED All Code Lockout...

Страница 12: ...12 Changing Master Code PIN 1 Press Press Enter 4 8 digit Master Code PIN Enter Master code PIN Press Press Press P N Rev A AYRD 156 INST FUL...

Страница 13: ...g User Codes PIN 2 Press Enter Master code PIN Press Enter 4 8 digit code PIN Press Press Press Press Press Master code must be created first PIN Max User Codes 250 in network P N Rev A AYRD 156 INST...

Страница 14: ...P N Rev A AYRD 156 INST FUL 14 3 Unlocking Door with Code PIN Press Unlock Enter PIN Press PIN Code Management Up to 250 Users in network Duplicate if necessary User Name PIN Code Code Chart...

Страница 15: ...Master Code NOTE press any key to complete handing of the lock Adding Lock To Z Wave Plus Network Your network controller first needs to be in inclusion or exclusion mode for the lock to be added or...

Страница 16: ...V battery in either direction to terminals below the touchscreen for backup power option Wake up the lock and enter your pin code to unlock the door Master Code It must be created prior to PIN The Mas...

Страница 17: ...ng Code Entry Limit 5 Times Shutdown Time 60 Seconds The Master code must be registered prior to any other programming of the lock PIN Default settings in bold M U Master Code Setting PIN User Code Re...

Страница 18: ...P N Rev A AYRD 156 INST FUL 18 Programming Troubleshooting Symptom Suggested Action...

Страница 19: ...the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is...

Страница 20: ...yright 2018 All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Residential Group is prohibited NOTE TO INSTALLER AND CONSUMER While Yale has incl...

Страница 21: ...1 Yale Locks Z Wave Plus System Integrators Guide Yale YRD156...

Страница 22: ...2 Contents Yale Z Wave Plus Product Info 3 Supported Command Classes 3 Association Table 3 Notifications Table 4 Configurable Parameters 6...

Страница 23: ...s Battery Command Class Door Lock Command Class Door Lock Logging Command Class Schedule Entry Lock Command Class User Code Command Class Time Parameters Command Class Time Command Class Association C...

Страница 24: ...s Where Alarm level represents user slot number 0xFB Master Code Manual Lock 0x15 0x01 by key cylinder or inside thumb turn 0x02 by touch function lock and leave 0x03 By inside button RF Operate Lock...

Страница 25: ...arm will be sent instead of the non access alarm Daily Repeating Schedule Set Erased 0x60 0x 01 max users Schedule s has been set erased for specified user ID Daily Repeating Schedule Enabled Disabled...

Страница 26: ...default is 30 seconds Wrong Code Entry Limit 4 1 byte 3 to 10 default is 5 times Shut down time after wrong code entries 7 1 byte 10 to 180 seconds default is 60 seconds operating mode 8 1 byte 00 nor...