Owner’s Manual
25
Compressor (cont’d)
Service & adjustments (cont’d)
Replacing the regulator
1
Release all air pressure from the air tank. See “Draining the tank”,
above.
2
Unplug the unit.
3
Using an adjustable wrench, remove the outlet pressure gauge and
quick-connect from the regulator.
4
Remove the regulator.
5
Apply pipe sealant tape to the nipple on the standpipe.
6
Assemble the regulator and orient correctly.
7
Reapply pipe sealant to outlet pressure gauge and quick-connect.
8
Reassemble outlet pressure gauge and quick-connect. Orient outlet
pressure gauge to read correctly. Tighten connect with wrench.
Note: Arrow indicates flow of air. Make sure it is pointing in the
direction of air flow.