Compressor w/Nailgun
22
Compressor (cont’d)
Before each start-up
1
Place ON/AUTO/OFF lever to “OFF.”
2
Turn the regulator knob counterclockwise to set the outlet pressure to
zero.
3
Attach hose and accessories.
Starting the compressor
1
Turn the ON/AUTO/OFF lever to “AUTO” and allow tank pressure to
build. The motor will stop when tank pressure reaches “cut-out”
pressure.
2
Turn regulator knob clockwise to increase pressure and stop when
desired pressure is reached.
The compressor is ready for use.
Maintenance
z
Check Safety Valve:
Before each use
z
Drain Tank:
Daily or after each use
Note: The hose or accessory will require a quick-connect plug of
the air outlet is equipped with a quick-connect socket.
WARNING! EXCESSIVE AIR PRESSURE CAUSES A HAZARDOUS RISK
OF BURSTING. CHECK THE MANUFACTURER’S MAXIMUM PRESSURE
RATING FOR AIR TOOLS AND ACCESSORIES. THE REGULATOR
OUTLET PRESSURE MUST NEVER EXCEED THE MAXIMUM PRESSURE
RATING.
WARNING! UNIT CYCLES AUTOMATICALLY WHEN POWER IS ON.
WHEN PERFORMING MAINTENANCE, YOU MAY BE EXPOSED TO
VOLTAGE SOURCES, COMPRESSED AIR OR MOVING PARTS.
PERSONAL INJURIES CAN OCCUR. BEFORE PERFORMING ANY
MAINTENANCE OR REPAIR, DISCONNECT POWER SOURCE FROM
THE COMPRESSOR AND BLEED OFF ALL AIR PRESSURE.