IMPORTANT SAFETY INSTRUCTIONS 

(CONTINUED)

BEFORE GATE OPERATOR INSTALLATION

Ÿ

Confirm that the gate operator being installed is 
appropriate for the application.

Ÿ

Confirm  that  the  gate  is  designed  and  built 
according  to  the  current  published  industry 
standards.

Ÿ

Confirm that all appropriate safety features and 
safety  accessory  devices  are  being  installed, 
including all entrapment protection devices.

Ÿ

Make sure that the gate opens and closes freely 
(by hand) before installing the operator.

Ÿ

Repair  or  replace  worn  or  damaged  gate 
hardware before installing the gate operator.

Ÿ

Eliminate all gaps in the sliding gate below a 6 
foot height that permits a 2 1/4” sphere to pass 
through any location. This includes the area of 
the adjacent fence covered when the gate is in 
the open position

Ÿ

Eliminate all gaps in a swing gate below a 4 foot 
height that permits a 4” sphere to pass through 
any location. This includes the hinge area of the 
gate.

GATE OPERATOR INSTALLATION

Ÿ

Operator must be disconnected from the power 
source  before  attempting  any  installation  of 
accessories.

Ÿ

Install gate operator according to the installation 
instructions in this manual.

Ÿ

Adjust the operator clutch or load sensing device 
to the minimum force setting that will allow for 
reliable gate operation.

Ÿ

Install the operator inside the fence line. Do not 
install the operator on the public side of the fence 
line.

Ÿ

Install  a  proper  electrical  ground  to  the  gate 
operator.

Ÿ

Controls  intended  for  user  activation  must  be 
located at least 6 feet away from any moving part 
of  the  gate,  and  where  the  user  is  prevented 
from  reaching  over,  under,  around,  or  through 
the gate to operate the controls.  

Ÿ

Outdoor or easily accessible controls shall have 
a security feature to prevent unauthorized use.

Ÿ

The stop and/or reset button must be located in 
the  line  of  sight  of  the  gate.  Activation  of  the 
operator  reset  control  shall  not  cause  the 
operator to move.

Ÿ

Install  a  minimum  of  2  warning  signs,  one  on 
each  side  of  the  gate  where  they  are  easily 
visible.  

Ÿ

Take pictures of the installation.

Ÿ

Test all safety features for proper function before 
placing  the  automatic  vehicular  gate  in 
operation.

MAINTENANCE

Ÿ

Train owners/users on the basic functions and 
safety  features  of  the  gate  system,  including 
how  to  turn  off  the  power  and  operate  the 
manual disconnect feature.

Ÿ

Leave  safety  instructions,  product  literature, 
installation  manual,  and  maintenance  manual 
with the owner or end user.

Ÿ

Explain to the owner or end user the importance 
of  routine  service  and  operator  testing  on  a 
monthly basis.

INSTALL THE GATE OPERATOR ONLY WHEN YOU 

HAVE READ THE FOLLOWING

36VDC MANUAL (09.2020)

Monday, August 31, 2020 8:57:51 AM

Содержание SL-175

Страница 1: ...36VDC MANUAL 09 2020 Monday August 31 2020 8 57 45 AM...

Страница 2: ...36VDC MANUAL 09 2020 Monday August 31 2020 8 57 51 AM...

Страница 3: ...ction Setting 22 23 Programmable Relay and Leaf Delay 24 Electronic Reversing Device ERD Adjustment 25 Timer Adjustment and Radio Setting 26 Dip Switch Functions 27 LED Diagnostics 28 WIRING ACCESSORI...

Страница 4: ...s advised that the power be turned off Always keep people and objects away from the gate No one should cross the path of a moving gate The gate operator must be tested monthly The gate must reverse on...

Страница 5: ...will allow for reliable gate operation Install the operator inside the fence line Do not install the operator on the public side of the fence line Install a proper electrical ground to the gate opera...

Страница 6: ...ervicing the general public and where unauthorized access is prevented via supervision by security personnel THE SIX TYPES OF OBSTRUCTION SENSING SYSTEMS TYPE A Inherent entrapment protection system T...

Страница 7: ...l disconnect Large gearbox 30 1 Small gearbox 10 1 Width X Length X Height 19 5 W X 20 L X 27 5 H 19 W X 31 L X 25 H Shipping Weight 320 lbs 435 lbs 110 lbs arm and wrench Emergency Release Mechanical...

Страница 8: ...DC CONCRETE PAD TOP VIEW FRONT VIEW AREA FOR CONDUITS GATE TRACK GATE TRACK GATE FOOTING DRIVE CHAIN LEVEL INSTALL 4 ABOVE GROUND WHEN POSSIBLE 14 DRIVE CHAIN LEVEL FOR REAR MOUNT GATE TRACK FOOTING F...

Страница 9: ...MOUNT INSTALLATION DRIVEWAY GATE CLOSED GATE OPERATOR TRACK FOOTING OPERATOR FOOTING FRONT VIEW OVERHEAD VIEW TRACK FOOTING OPERATOR FOOTING GATE IN OPEN POSITION 36VDC MANUAL 09 2020 Monday August 3...

Страница 10: ...7 27 3 4 14 TOTAL COVER HEIGHT DRIVE CHAIN LEVEL TOP OF OPERATOR PAD SL 175 DC FRONT MOUNT INSTALLATION CONTINUED 36VDC MANUAL 09 2020 Monday August 31 2020 8 57 57 AM...

Страница 11: ...OTING TRACK FOOTING TRACK FOOTING FRONT VIEW OVERHEAD VIEW GATE OPERATOR FOOTING MOVE ONE IDLER TO THE BOTTOM CENTER HOLE AND FOLLOW THE CHAIN PATH AS SHOWN CHAIN PATH GATE POST FRONT IDLER SAFETY GUA...

Страница 12: ...ric sensor or contact edge for each entrapment zone prior to gate operation The operator cycles power to the external entrapment protection device and checks for device signals If the operator does no...

Страница 13: ...oop layout When connecting to an All O Matic circuit board use the following Safety Loop Normally Closed N C Contacts Exit Loop Normally Open N O Contacts Wires MUST be twisted from the exit point of...

Страница 14: ...NEVER use two wires for the ground Check the local city code for proper earth ground rod type and grounding procedures OPERATORS MUST BE PROPERLY GROUNDED 230V 115V GRD LINE 2 LINE 1 Use a minimum of...

Страница 15: ...imit lock plate outwards 3 Turn the limit nut in the desired direction Toward the switch to decrease travel and away from the switch to increase travel 4 Place limit plate back to its locked position...

Страница 16: ...5 OPERATOR PLASTIC COVER OPERATOR FRAME 6 RED HEAD BOLTS 3 4 X 5 AREA FOR CONDUIT S OPERATOR CONCRETE PAD 11 5 30 4 20 24 5 LOW VOLTAGE CONDUIT HIGH VOLTAGE CONDUIT FOOTING FOR GATE OPERATOR INSTALL 4...

Страница 17: ...shaft D The distance from the center of the gate hinge to the center of the operator shaft Minimum distance The minimum distance required behind an open gate and an obstruction ie wall bush etc If thi...

Страница 18: ...of the gate bracket This will be point Z BRACKET GATE IN OPEN POSITION GATE IN CLOSED POSITION Step 2 Chalk out a line connecting point Y Z and going past point as shown in the drawing below The cente...

Страница 19: ...NTER OF OPERATOR SHAFT X X POINT Y POINT Z Step 4 Cut the primary arm section the measurement you recorded in Step 3 half the distance between point Y and point Z The secondary arm makes up the rest o...

Страница 20: ...1001 1001 1001 1001 1001 1210 1001 1001 1001 1001 1002 1002 1002 1002 1002 1002 1002 1002 1002 1002 1002 1002 1002 2001 2001 2001 4750 4750 145 1212 4021 2491 2491 2262 2402 9531 4750 1131 1332 1001...

Страница 21: ...e operator cycles power to the external entrapment protection device and checks for device signals If the operator does not receive the correct feedback from the device the gate will not operate ENTRA...

Страница 22: ...ires 6 turns per foot as shown below Improper twisting of wires can cause loop issues When using an inside and outside safety loop loops must be WIRED IN SERIES OUTSIDE SAFETY LOOP INSIDE SAFETY LOOP...

Страница 23: ...for proper earth ground rod type and grounding procedures OPERATORS MUST BE PROPERLY GROUNDED Use a minimum of a 20 amp dedicated circuit for power Power Connection 115 VAC 230 VAC Single Phase LINE 1...

Страница 24: ...urn the power OFF on the gate operator 2 Use an allen wrench to loosen up the limit cams Turn the limit cams in the desired direction 3 Tighten the allen screw 4 Turn the power ON on the gate operator...

Страница 25: ...2 20M 90R9 10R0 1000 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 476E 900R3 476E 900R3 5W 01 I0615 I O 710 710 710 710 710 710 710 710 710 710 SS 14 SS 14 829B...

Страница 26: ...6E 900R3 476E 900R3 5W 01 I0615 I O 710 710 710 710 710 710 710 710 710 710 SS 14 SS 14 829B R616 90R9 10R0 1000 SS 14 829B R616 90R9 10R0 1000 SS 14 829B R616 602 S26S 602 S26S IR2110S 0618 IOR IR211...

Страница 27: ...justment from 0 6 seconds Turn clockwise for less time Turn counter clockwise for more time 1 2 OPEN 3 DEVICE DEVICE POWER SUPPLY DIP SWITCH 3 OPENING AND CLOSING DELAY FUNCTION SETTING 1 3 DELAY 0 TO...

Страница 28: ...1002 2262 2262 2262 2262 2262 2262 2402 2402 2402 2402 2402 2402 2402 20M 90R9 10R0 1000 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 476E 900R3 476E 900R3 5W 0...

Страница 29: ...1002 1002 1002 1002 1002 1002 1002 1002 1002 1002 1002 1002 1002 1002 2262 2262 2262 2262 2262 2262 2402 2402 2402 2402 2402 2402 2402 20M 90R9 10R0 1000 1501 1501 1501 1501 1501 1501 1501 1501 1501 1...

Страница 30: ...EN VAGEO 1442 10W 11R J 30 RESET TIMER TIMER switch ON activates the automatic close timer RADIO RADIO switch ON allows the radio receiver to override the automatic close timer OSC OSC switch ON allow...

Страница 31: ...lled MON_CLOSE ON when the MON_CLOSE input is activated open circuit to common or when a device is not installed TIMER Blinks when the timer is counting down to close automatically CLOSE CMD ON when t...

Страница 32: ...Photo Eye Telephone System Pedestrian Switch Push Button Card Reader C C Power Detect Loop Fail Reset 2 1 0 0 SENS LEVEL BOOST ON PULSE FREQ 0 0 OFF PRES 2 1 1 2 3 4 5 6 SAFETY REVERSE LOOP DETECTOR...

Страница 33: ...ect the power wires to the COMMON and MON 12 24VDC IMPORTANT You must use the MON 12 24VDC to properly monitor entrapment protection devices To turn this voltage on for initial setup press reset butto...

Страница 34: ...ng it will reverse for 2 seconds and stop if it senses an obstruction This input does nothing in the closing direction Upon power up if a device is not detected the operator will assume that one is no...

Страница 35: ...POWER MON_12 24VDC EMX NIR 50 325 WIRE BOARD TERMINAL BLACK MON_CLOSE OR MON_OPEN WHITE COMMON BLUE COMMON BROWN MON_12 24VDC TRANSMITTER SOLUTIONS R50R UL R32P UL SR33HD SR66HD CONTACT BOARD TERMINA...

Страница 36: ...nt frequencies for each loop detector to eliminate interference Outside Safety loop Inside Safety loop Exit loop WHEN USED Exit Loop Phantom Loop Safety Loop See side for Jumper setting Loop Connectio...

Страница 37: ...02 2402 2402 2402 2402 20M 90R9 10R0 1000 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 1501 476E 900R3 476E 900R3 5W 01 I0615 I O 710 710 710 710 710 710 710 710 710...

Страница 38: ...he master slave communication wires to DATA and DATA The M S LINK LED should be ON on both machines 4 Connect all accessories to the master operator Accessories installed on the slave operator will no...

Страница 39: ...down transformer with the appropriate voltage for the specific lock accessory Most operators include a 120VAC outlet for the step down transformer Connections Plug the lock device transformer to the...

Страница 40: ...5GN DR127 330 43CL07 E CMX 309FB C 8 0000 M 535202 CMX 309FB C 8 0000 M 535202 CMX 309FB C 8 0000 M 535202 C8RB LMC64 82AIM 1001 0022 1001 1001 1001 1001 1001 1001 1001 1001 1001 0022 F MOC8050 629Q F...

Страница 41: ...0 KE 710 KE 710 KE 710 KE 710 KE 710 KE O U R N 3 8 6 B S 3 1 3 O U R N 3 8 6 B S 3 1 3 O U R N 3 8 6 B S 3 1 3 O U R N 3 8 6 B S 3 1 3 O U R N 3 8 6 B S 3 1 3 1 2 OPEN 3 710 KE 710 KE 710 KE 710 KE 7...

Страница 42: ...A168 20AU 0743 MAAF S21B 101 we 100 HFK 7J2 100 HFK 7J2 33 HFK 5GN DR127 330 43CL07 E CMX 309FB C 8 0000 M 535202 CMX 309FB C 8 0000 M 535202 CMX 309FB C 8 0000 M 535202 C8RB LMC64 82AIM 1001 0022 100...

Страница 43: ...FETY EXIT 115VAC LIMIT SWITCHES Procedures to manually open Gate 1 Turn operator power OFF 2 Push foot pedal down and move to the left to lock pedal in down position 3 Push gate open 36VDC MANUAL 09 2...

Страница 44: ...warranties either expressed or implied andALL O MATIC INC shall not be liable for consequential damage All implied warranties of merchantability and or fitness for a particular purpose are hereby disc...

Страница 45: ..._________ ________________________________________ ________________________________________ ________________________________________ ________________________________________ __________________________...

Страница 46: ..._________ ________________________________________ ________________________________________ ________________________________________ ________________________________________ __________________________...

Страница 47: ...44 36VDC MANUAL 09 2020 Monday August 31 2020 8 58 28 AM...

Страница 48: ...45 36VDC MANUAL 09 2020 Monday August 31 2020 8 58 32 AM...

Отзывы: