SW-375 DC ELECTRICAL CONNECTION
Ÿ
All gate operators
MUST
be properly grounded. This minimizes or prevents damage due to electrical charge,
such as a near lightening strike or an electrical static discharge.
Ÿ
Use a single wire for the ground.
DO NOT
splice two wires for the ground. If the wire breaks or is cut, replace it
with a single length wire.
NEVER
use two wires for the ground.
Ÿ
Check the local city code for proper earth ground rod type and grounding procedures.
OPERATORS
MUST
BE PROPERLY GROUNDED!
Ÿ
Use a minimum of a
20-amp
, dedicated circuit for power.
Power Connection
115 VAC
230 VAC Single Phase
LINE 1
115V HOT
230V LINE 1
LINE 2
115V NEUTRAL
230V LINE 2
GND
GROUND
GROUND
1
15V
GRD LINE 1 LINE 2
120 VAC OUTLET
POWER SWITCH
230V
NOTE:
WHEN APPLYING
230V TO THE OPERATOR,
MAKE SURE VOLTAGE
SWITCH IS FLIPPED TO 230V
IF YOU ARE USING 120 VAC
AS THE POWER SOURCE AND
WANT TO USE THE 120 VAC
ACCESSORY OUTLET, CONNECT
THE WHITE WIRE FROM THE
OUTLET TO NEUTRAL.
36VDC MANUAL (09.2020)
Monday, August 31, 2020 8:58:02 AM