background image

TABLE OF CONTENTS

SAFETY AND INTRODUCTION

 

Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

 

UL 325 Class Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

 

Operator Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5

INSTALLATION

 

SL-45 DC Concrete Pad Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

 

SL-90 DC Concrete Pad Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

 

SL-100 DC [FP] Concrete Pad Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

 

SL-150 DC Concrete Pad Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

 

Front and Rear Mount Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-12

 

Entrapment Protection Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

 

Loop Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

 

Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

 

Gate Travel Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

 

SL-150 DC Clutch Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

BOARD FEATURES

 

Gate Opening Direction Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

 

Programmable Relay and Leaf Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

 

Electronic Reversing Device (ERD) Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . 20

 

Timer Adjustment and Radio Setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

 

Dip Switch Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

 

LED Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

ACCESSORY INSTALLATION

 

Accessory Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

 

Monitored Entrapment Protection Device Connections . . . . . . . . . . . . . . . . . 25-26

 

Plug-in Detector Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

 

Three Button Station Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

 

Master/Slave Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

 

Magnetic/Solenoid Lock Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

 

Radio Receiver Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

SOLAR INSTALLATION

 

Solar Panel Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

 

External Solar System Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

EMERGENCY RELEASE INSTRUCTIONS

 

Emergency Release for SL-45 DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

 

Emergency Release for SL-90 DC, SL-100 DCFP, and SL-150 DC . . . . . . . . . . 35

ACCESSORIES AND PARTS BREAKDOWN

 

Pad Lock Tabs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

 

SL-45 DC Blowout Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Check Website

 

SL-90 DC Blowout Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Check Website

 

SL-100 DC[FP] Blowout Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . Check Website 

 

SL-150 DC Blowout Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Check Website

WARRANTY AND CUSTOMER RECORD

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Содержание SL-100 DC

Страница 1: ...Rev UL2 10 17 ...

Страница 2: ......

Страница 3: ...r Adjustment and Radio Setting 21 Dip Switch Functions 22 LED Diagnostics 23 ACCESSORY INSTALLATION Accessory Connections 24 Monitored Entrapment Protection Device Connections 25 26 Plug in Detector Installation 27 Three Button Station Connection 28 Master Slave Connection 29 Magnetic Solenoid Lock Connection 30 Radio Receiver Connection 31 SOLAR INSTALLATION Solar Panel Connection 32 External Sol...

Страница 4: ... the gate is not moving It is advised that the power be turned off Always keep people and objects away from the gate No one should cross the path of a moving gate The gate operator must be tested monthly The gate must reverse on contact with a rigid object or stop when an object activates the non contact sensor s Always re test the operator after adjusting the limits and or force Failure to adjust...

Страница 5: ... minimum force setting that will allow for reliable gate operation Ÿ Install the operator inside the fence line Do not install the operator on the public side of the fence line Ÿ Install a proper electrical ground to the gate operator Ÿ Controls intended for user activation must be located at least 6 feet away from any moving part of the gate and where the user is prevented from reaching over unde...

Страница 6: ...cted access locations not servicing the general public and where unauthorized access is prevented via supervision by security personnel THE SIX TYPES OF OBSTRUCTION SENSING SYSTEMS TYPE A Ÿ Inherent entrapment protection system This system must sense and initiate the reverse of the gate within 2 seconds of contact with a solid object TYPE B1 Ÿ Non contact sensor photoelectric sensor or equivalent ...

Страница 7: ...ts Duty Cycle Continuous Continuous Temperature Range 40º to 160º 40º to 160º Gear Box Ratio Approx 29 1 20 1 with internal disconnect Dimensions 11 W X 14 5 L X 15 5 H 15 5 W X 18 5 L X 17 H Shipping Weight 60 lbs 93 lbs Emergency Release Push open in the event of a power failure Foot pedal release Belt Size N A 4L 230 Main Sprocket 41B15 X 5 8 bore 41B22 X 7 8 bore Chain Size 41NP 20 included 41...

Страница 8: ...perature Range 40º to 160º 40º to 160º Gear Box Ratio SL 100 DC 10 1 SL 100 DCFP 20 1 30 1 with internal clutch Dimensions 12 W X 17 5 L X 23 5 H 15 W X 19 5 L X 25 H Shipping Weight 130 lbs 150 lbs Emergency Release SL 100 DC Push open SL 100 DCFP Foot pedal release Foot pedal release Belt Size SL 100 DC 4L 300 SL 100 DCFP 4L 260 N A Main Sprocket 41B22 X 7 8 bore 40B22 X 1 bore Chain Size 41NP 2...

Страница 9: ...OTAL COVER HEIGHT LOW VOLTAGE CONDUIT HIGH VOLTAGE CONDUIT TRACK FOOTING TOP VIEW FRONT VIEW INSTALL 4 ABOVE GROUND WHEN POSSIBLE 24 8 5 24 8 5 4 RED HEAD BOLTS 1 2 X 3 1 2 AREA FOR CONDUIT OPERATOR CONCRETE PAD OPERATOR FRAME GATE TRACK GATE TRACK FOOTING MINIMUM 5 10 11 10 3 ...

Страница 10: ... ABOVE GROUND WHEN POSSIBLE FOOTING FOR GATE OPERATOR LOW VOLTAGE CONDUIT HIGH VOLTAGE CONDUIT FRONT VIEW TOP VIEW 24 24 15 2 25 16 4 RED HEAD BOLTS X 3 AREA FOR CONDUIT S OPERATOR CONCRETE PAD OPERATOR PLASTIC COVER GATE TRACK GATE TRACK FOOTING MINIMUM 5 10 11 25 13 5 4 5 11 5 ...

Страница 11: ... 2 AREA FOR CONDUIT OPERATOR CONCRETE PAD OPERATOR FRAME OPERATOR PLASTIC COVER GATE TRACK GATE TRACK FOOTING MINIMUM 5 10 17 2 5 CHAIN LINE 23 5 TRACK FOOTING 8 24 4 6 5 4 5 13 5 INSTALL 4 ABOVE GROUND WHEN POSSIBLE FOOTING FOR GATE OPERATOR 12 25 TOP VIEW FRONT VIEW ...

Страница 12: ... 24 16 25 30 7 5 4 RED HEAD BOLTS X 3 AREA FOR CONDUIT GATE TRACK GATE TRACK FOOTING MINIMUM 5 10 15 20 1 75 CHAIN LINE 8 24 4 INSTALL 4 ABOVE GROUND WHEN POSSIBLE FOOTING FOR GATE OPERATOR TRACK 6 10 25 TOP VIEW FRONT VIEW 3 ...

Страница 13: ...10 FRONT MOUNT INSTALLATION DRIVEWAY GATE CLOSED GATE OPERATOR TRACK FOOTING OPERATOR FOOTING FRONT VIEW OVERHEAD VIEW TRACK FOOTING OPERATOR FOOTING GATE IN OPEN POSITION ...

Страница 14: ...TOR PAD SL 150 DC SL 100 DC SL 100 DC FP 23 6 5 SL 45 DC SL 90FP DC 15 5 6 TOTAL COVER HEIGHT DRIVE CHAIN LEVEL TOTAL COVER HEIGHT DRIVE CHAIN LEVEL TOTAL COVER HEIGHT TOP OF OPERATOR PAD TOP OF OPERATOR PAD TOTAL COVER HEIGHT FRONT MOUNT INSTALLATION CONTINUED 6 25 16 6 5 ...

Страница 15: ...ATE OPERATOR OPERATOR FOOTING OPERATOR FOOTING TRACK FOOTING TRACK FOOTING FRONT VIEW OVERHEAD VIEW GATE OPERATOR FOOTING MOVE ONE IDLER TO THE BOTTOM CENTER HOLE AND FOLLOW THE CHAIN PATH AS SHOWN CHAIN PATH GATE POST FRONT IDLER SAFETY GUARD GATE CHAIN CONNECTION TO GATE ...

Страница 16: ...vice non contact photoelectric sensor or contact edge for each entrapment zone prior to gate operation The operator cycles power to the external entrapment protection device and checks for device signals If the operator does not receive the correct feedback from the device the gate will not operate INSIDE PROPERTY OUTSIDE PROPERTY OUTSIDE PROPERTY OVERHEAD VIEW FRONT INSTALLATION REAR INSTALLATION...

Страница 17: ...loop layout When connecting to an All O Matic circuit board use the following SAFETY LOOP Normally Closed N C Contacts EXIT OPEN CMD Normally Open N O Contacts See page 27 for LPR 1 loop rack wiring Wires MUST be twisted from the exit point of the loop saw cut to the loop detector Twist loop wires 6 turns per foot as shown below Improper twisting of wires can cause loop issues When using an inside...

Страница 18: ...ound Ÿ Check the local city code for proper earth ground rod type and grounding procedures Ÿ Use UL listed conduits for power wire enclosure OPERATORS MUST BE PROPERLY GROUNDED 230V 115V GRD LINE 2 LINE 1 Ÿ Use a minimum of a 20 amp dedicated circuit for power Power 115 VAC 50 60Hz 230 VAC 50 60Hz Single Phase LINE 1 115V HOT 230V LINE 1 LINE 2 115V NEUTRAL 230V LINE 2 GND GROUND GROUND POWER AND ...

Страница 19: ...n the power OFF on the operator 2 Push the limit lock plate down on the SL 45 DC SL 90 DC and SL 100 DC or outwards on the SL 150 DC 3 Turn the limit nut toward the switch to DECREASE travel and away from the switch to INCREASE travel 4 Place limit plate back to its locked position MUST be done for gate to hold its limits 5 Turn the power ON to the operator 6 Run the gate operator open and close I...

Страница 20: ...s important to not over tighten the clutch as it is a method of protecting the operator Follow these instructions to adjust the clutch when necessary Ÿ To increase the torque use a pipe wrench to turn the clutch nut clockwise Ÿ Turn the nut 1 2 a turn at a time until the operator is able to move the load of the gate without the clutch slipping Ÿ Once the operator is able to move the gate without t...

Страница 21: ... Ÿ The direction of gate opening is determined from behind the gate operator Ÿ LEDs will show opening and closing direction when the gate is moving Ÿ OPEN L R switch OFF is for left hand opening Ÿ OPEN L R switch ON is for right hand opening OPEN TO THE RIGHT OPEN TO THE LEFT 1001 1001 1001 1001 1 2 3 4 5 6 7 8 OPEN GATE OPENING DIRECTION SETTING ...

Страница 22: ...ble alarm or strobe light to warn when the gate is in motion 3 Alarm system output Activates the relay when the gate is forced open 4 ON when gate is not fully closed Typically used for a gate position indicator DELAY SETTINGS The ALL BLDC board includes a delay option for open or close cycles This delay option is most commonly used on swing gate applications However some slide gate applications m...

Страница 23: ...e to reverse direction when it comes in contact with an obstruction The amount of force required to reverse the gate s direction depends on the ERD sensitivity setting The ERDs must be adjusted for the operator to provide regular reliable safe operations If the gate reverses direction on its own without hitting an obstruction the ERD is too sensitive If the gate does not reverse when it hits an ob...

Страница 24: ...nds TIMER OFF Gate operation is push button to open push button to close RADIO ON To override the timer and allow the radio receiver to close the gate before the timer Turn potentiometer counter clockwise for more time Turn potentiometer clockwise for less time 60 SEC 0 SEC 60 SEC 0 SEC NOTE If Potentiometer is turned all the way counter clockwise the timer is disabled and the gate WILL NOT close ...

Страница 25: ...fety loop Once the vehicle has cleared the loop the gate will stop and close If a second vehicle goes over the loop while the gate is closing the gate will stop The vehicle must get off of the loop before the gate continues to close forcing the second vehicle to present valid credentials This is a true one pass anti tailgating feature to be used with safety loops SLAVE This feature is used in dual...

Страница 26: ...timer is counting down to close automatically CLOSE CMD ON when the CLOSE CMD input is activated closed circuit to common CLOSING ON while the gate is in the close cycle OPENING ON while the gate is in the open cycle CLOSE LIMIT ON while the limit nut is activating the close limit switch OPEN LIMIT ON while the limit nut is activating the open limit switch LOW BATTERY ON when the batteries are low...

Страница 27: ...6 N O The circuit board has 12 24VDC terminals that provide up to 750mAmps on 24VDC and 500mAmps on 12VDC to power accessories such as loop detectors keypads etc If the total current draw of your accessories exceeds the rated current for any of the 12 24VDC terminals a separate power supply transformer is required When installing a safety loop detector or pedestrian switch STOP_CMD make sure to re...

Страница 28: ... a need for more than 1 entrapment protection device for each direction use a multi input module from Miller Edge model MIM 62 COMMON STOP CMD COMMON MON 12 24VDC MON_OPEN MON_CLOSE CLOSE PHOTO EYE COM N C N C OR COM CLOSE EDGE OPEN PHOTO EYE COM N C N C OR COM OPEN EDGE Use jumper to select monitored device voltage MONITORED ENTRAPMENT PROTECTION DEVICE CONNECTIONS MON_CLOSE LED will indicate whe...

Страница 29: ...N_OPEN COM COMMON POWER COMMON POWER MON_12 24VDC EMX NIR 50 WIRE BOARD TERMINAL BLACK MON_CLOSE OR MON_OPEN WHITE COMMON BLUE COMMON BROWN MON_12 24VDC TRANSMITTER SOLUTIONS R50R UL R32P UL SR33HD SR66HD CONTACT BOARD TERMINAL N C 3 MON_CLOSE OR MON_OPEN COM 5 COMMON NON POLARITY 1 COMMON 12 30 VDC AC 2 MON_12 24VDC MILLER EDGE RBAND MINIMUM 6 WIRES REQUIRED SWITCH CONTACT BOARD TERMINAL SW 1 ON ...

Страница 30: ... to eliminate interference Outside Safety loop Inside Safety loop Exit loop WHEN USED Exit Loop Phantom Loop Safety Loop See side for Jumper setting Loop Connections NOT INCLUDED ON SL 45DC Exit Loop Loop Loop Safety Phantom 24VAC 12VDC Ground Exit Phantom Safety Only for swing gates 24VAC 12VDC GROUND EXIT PHANTOM SAFETY DC BOARD LOOP RACK EXIT SAFETY PHANTOM GROUND 12 VDC RED BLACK GREEN BROWN W...

Страница 31: ...e diagram below for wiring instructions Ÿ NOTE STOP_CMD jumper must be removed if a three button station is installed Push Button Contacts Terminals Open Common Normally Open COMMON EXIT OPEN_CMD Close Common Normally Open COMMON CLOSE_CMD Stop Common Normally Closed COMMON STOP_CMD COM OPEN CLOSE STOP STOP CMD JUMPER N C N O N O THREE BUTTON STATION CONNECTION NOTE CMD Command ...

Страница 32: ... slave board Press the RESET button on the slave board 3 Connect the master slave communication wires to DATA and DATA The M S LINK LED should be ON on both machines 4 Connect all accessories to the master operator Accessories installed on the slave operator will not work USE UL LISTED CONDUIT SHIELDED CABLE CONNECT SHIELD TO SLAVE OPERATOR FRAME ONLY MASTER BOARD SLAVE BOARD SLAVE SWITCH ONLY ON ...

Страница 33: ...ppropriate voltage for the specific lock accessory Most operators include a 120VAC outlet for the step down transformer The SL 45DC does not include a 120VAC outlet Connections Plug the lock device transformer to the 120VAC outlet plug For Magnetic Lock Wire nut one wire from transformer directly to one wire of the magnetic lock The other wire from transformer will be connected to the board relay ...

Страница 34: ...lack negative wire to terminal 1 COMMON and the red positive wire to terminal 3 12 24VDC on the receiver terminal strip as shown below RADIO dip switch ON allows the radio receiver to override the automatic close timer See TIMER adjustment page for more details 3 2 1 RECEIVER TERMINAL STRIP LOCATED OUTSIDE CONTROL BOX 4 WIRE 12 24VDC RADIO RECEIVER BOARD ALSO PROVIDES 12VDC AND 24VDC ACCESSORY POW...

Страница 35: ...eature that makes it more efficient than other types of regulators For a solar installation upgrade the batteries according to usage When the application requires more than 80 watts of solar power an external charge controller regulator is necessary See next page for external solar system For information on solar applications solar panel sizes battery size etc please call All O Matic CONNECT 24V PA...

Страница 36: ...001 1001 1001 1001 1001 1001 1001 0022 F MOC8050 629Q F MOC8050 629Q F MOC8050 629Q F MOC8050 629Q 710 KE 710 KE 710 KE 710 KE 710 KE 710 KE 710 KE O U R N 3 8 6 B S 3 1 3 O U R N 3 8 6 B S 3 1 3 O U R N 3 8 6 B S 3 1 3 O U R N 3 8 6 B S 3 1 3 O U R N 3 8 6 B S 3 1 3 1 2 OPEN 3 710 KE 710 KE 710 KE 710 KE 710 KE 710 KE 1 2 3 4 5 6 7 8 OPEN VAGEO 1442 10W 11R J 30 When using an external solar packa...

Страница 37: ...01 1002 1002 1002 1002 1002 1002 1002 1002 1002 1002 1002 1002 1002 2001 2001 2001 4750 4750 145 1212 4021 2491 2491 2262 9531 4750 1131 1332 1001 1001 1001 1001 1001 1001 0022 1001 90R9 90R9 90R9 10R0 10R0 10R0 1000 1000 1000 1501 1501 1501 1501 1501 1501 1501 1501 1501 476E 900R3 476E 900R3 107A 911C0 F MOC8050 629Q MAGNECRAFT W107DIP 3 5W 01 I0615 I OO 710 KE 710 KE 710 KE 710 KE 710 KE 710 KE ...

Страница 38: ...S Procedures to manually open the SL 90 DC SL 100 DCFP and SL 150 DC 1 Turn operator power OFF 2 Push foot pedal down and move to the side to keep pedal in down position 3 Push gate open NOTE These operators are equipped with a kill switch on foot pedal Even if operator power is turned ON the operator will not run while the foot pedal is down The STOP CMD LED will indicate the foot pedal is presse...

Страница 39: ...e provided in the hardware bag for the SL 45 DC only Remove bolt and install lock tabs for cover to secure with a pad lock Lock kits are available for purchase for the SL 90 DC SL 100 DC SL 100FP DC and SL 150 DC PAD LOCK TABS ...

Страница 40: ... the responsibility of the owner These warranties are in lieu of all other warranties either expressed or implied andALL O MATIC INC shall not be liable for consequential damage All implied warranties of merchantability and or fitness for a particular purpose are hereby disclaimed and excluded This limitation is not valid in jurisdictions which do not allow limitation of incidental or consequentia...

Страница 41: ...__ ________________________________________ ________________________________________ ________________________________________ ________________________________________ ________________________________________ ________________________________________ ________________________________________ ________________________________________ ________________________________________ ____________________________...

Страница 42: ...__ ________________________________________ ________________________________________ ________________________________________ ________________________________________ ________________________________________ ________________________________________ ________________________________________ ________________________________________ ________________________________________ ____________________________...

Страница 43: ...40 ...

Страница 44: ...41 ...

Отзывы: