16
EACH NOTCH
EQUALS
ABOUT 1/2” OF
TRAVEL
EACH NOTCH
EQUALS ABOUT
1/2” OF TRAVEL
LIMIT NUTS
LIMIT NUT LOCK PLATE
SL-100 DC[FP]
LIMIT NUTS
LIMIT SWITCH
LIMIT NUT LOCK PLATE
SL-150 DC
Locate the limit switches (limit switches will be in the limit box on SL-150 DC) and follow the steps below:
1: Turn the power
OFF
on the operator.
2: Push the limit lock plate down (on the SL-45 DC, SL-90 DC, and SL-100 DC) or outwards (on the
SL-150 DC)
3: Turn the limit nut toward the switch to DECREASE travel and away from the switch to INCREASE
travel.
4: Place limit plate back to its locked position. (
MUST
be done for gate to hold its limits)
5: Turn the power
ON
to the operator.
6: Run the gate operator open and close. If additional adjustment is needed, repeat the steps.
SL-45 DC
SL-90 DC
GATE TRAVEL ADJUSTMENT