22
1 2 3 4 5 6 7 8
-----------------------OPEN------------------------
TIMER
RADIO
OSC
FAIL SC/SF
1-PASS
SLAVE
AUTO OPEN
OPEN L/R
OFF ON
NOTE:
IF ANY CHANGES ARE
MADE TO THE DIPSWITCHES
WITH THE POWER ON, PRESS
THE
MAIN RESET
BUTTON TO
RECOGNIZE THE CHANGES.
TIMER
TIMER
switch
“ON”
activates the automatic close
timer.
RADIO
RADIO
switch
“ON”
allows the radio receiver to
override the automatic close timer.
OSC
OSC
switch
“ON”
allows the radio receiver to stop
and reverse the gate in any direction. During a cycle,
the first signal stops the gate. A second signal
reverses the gate.
FAIL SC/SF
ON
for
Fail-Safe
: Upon power failure, board will monitor
battery voltage to make sure gate opens before battery
completely drains.
OFF
for
Fail-Secure
: Upon power
failure, gate will run until battery is low and lock closed.
1-PASS
1-PASS
switch
“ON”
allows the gate to open until
one vehicle goes over the safety loop. Once the
vehicle has cleared the loop, the gate will stop and
close. If a second vehicle goes over the loop while
the gate is closing, the gate will stop. The vehicle
must get off of the loop before the gate continues to
close, forcing the second vehicle to present valid
credentials. This is a true one pass, anti-tailgating
feature to be used with safety loops.
SLAVE
This feature is used in dual gate applications. The
SLAVE
switch will be
“ON”
only on the slave
operator. All other dip switches will be “off”.
SLAVE
switch will be
“OFF”
on the master operator. Set
desired dip switch settings on the master operator
only.
AUTO OPEN
This feature is to automatically open the gate on
power interruption. It is a very particular feature
used in areas where the fire department requires the
gate to open automatically after a power outage.
Set this dip switch “ON” when this feature is desire.
OPEN L/R
OPEN L/R
switch
“ON”
is used for right hand
opening of the gate. The
“OFF”
position is used
for left hand opening of the gate.
RESET