6. Prepare enough fresh water and soap in case battery acid contacts skin, clothing or
eyes.
7. Wear complete eye protection and clothing protection. Avoid touching your eyes
while working near batteries.
8. If battery acid contacts skin or clothing, wash immediately with soap and water. If
acid enters your eyes, immediately flood in cold water and get medical attention
immediately.
9. If you need to remove a battery, always remove the ground terminal from the
battery first. Make sure all accessories are off so you don’t cause a spark.
10. Always use identical types of batteries.
11. Never install old or untested batteries. Check each battery’s date code label to
ensure age and type.
12. Batteries are temperature sensitive. For optimal performance, they should be
installed in a stable temperature environment.
13. Always recycle old batteries. Contact your local recycling center for proper
disposal information.
General Information
Thank you for purchasing the APS inverter series.
The inverter is a combination of an inverter, charger.
It is packed with unique features and it is one of the most advanced inverter/charger
in the market today.
The inverter features an AC bypass circuit, powering your gate operators and access
controls or any appliance from the utility power or generator power while charging the
battery. When utility power fails, the battery backup system keeps your equipment
powered until utility power is restored. Internal protection circuits prevent over-
discharging the batteries by shutting down inverter when a low battery condition
occurs. When utility or generator power is restored, the inverter transfer to the AC
source and recharges the batteries.
The series inverter can also serve as a central hub of renewable energy system. Set
the series inverter to battery priority mode to designate it to inverter-preferred UPS
configuration. In this configuration, the load power is normally provided by the inverter,
However, if the inverter output is interrupted, an internal transfer switch automatically
transfers the load from the inverter to commercial utility power. The transfer time
between inverter and line is short(6ms typically), and such transfers are normally not
detected by even highly sensitive loads. Upon restoration of battery capacity, the
inverter will transfer back to inverter power (battery).
In the line priority mode, when utility power cuts off (or drops below acceptable range),
the transfer relay is de-energized and the load is automatically transferred to inverter
output.
Once the qualified utility power is restored, the relay is energized and the load is
automatically reconnected to utility power.
It features power factor, sophisticated multi-stage charging and pure sine wave output
with unprecedentedly high surge capability to meet demanding power needs of
inductive loads without endangering the equipment.
The inverter is equipped with a powerful charger of up to 70Amp (depending on
mode). The overload capacity is 125~150% of continuous output for up to 20 seconds
to reliably support tools and equipment longer.
Another important feature is that the inverter can be easily customized to solar priority
by DIP switch, this helps to extract maximum power from solar in renewable energy
systems.
To get the most out of the power inverter, it must be installed, used and maintain
properly.
Please read the instructions in the manual before installing.
Содержание APS1000-12
Страница 1: ...POWER INVERTER APS1000 12 APS2000 24...
Страница 6: ...Battery Type Selector Charge Current Adjuster 25 50 75 100...
Страница 13: ...120Vac 75Vac 2 80Vac 2 140Vac 140Vrms 135Vac 2 2 30A 40A APS1000 12 APS2000 24 Same as Input Waveform...
Страница 16: ......
Страница 20: ...By restarting the inverter Turn it OFF and back ON...
Страница 23: ......
Страница 24: ...420 00233 03 POWER INVERTER...