Packaging 

Normally (depending model and order quantity) the heaters are packed per 1, 2, 4 of 6 in a box. Always 
check the heaters for transport damage directly after receiving them. Note that the heaters will be a bit 
discoloured by temperature due to a 5 minutes quality check after manufacturing. 
 
The  heaters  are  pre-assembled.  In  some  cases,  if  there  is  a  risk  for  damaging  during  transport,  the 
thermocouple  sensor  is  separated  from  the  gas  safety  device.  Re-assembly  can  be  simply  done  by 
screwing the M8 nut (29) of the sensor back on the safety device (14). Do not tighten too strong. 
 
The thermostat knob is always delivered separated from the thermostat valve. 
1) Remove the protection cover from the thermostat valve.  
2) Turn the knob on maximum temperature and push the knob on the valve.  
3) Fix the knob by turning the large metal screw ring till it stops (at least 2 turns, hand tight).  
 
For  thermostats  with  a  remote  sensor  only:  bend  the  sensor  line  carefully  (no  sharp  bends)  to  the 
thermostat  valve  and  secure  the  sensor  line  with  a  ty-rap  around  the  red  protection  lining  and  the 
thermocouple  safety  device  (see  picture).  Note  that  the  tubing  is  hollow,  a  sharp  bend  will  close  the 
tubing  and  makes  the  sensor  worthless.  The  chance  of  breaking  the  line  at  the  entrance  of  the 
thermostat knob is largely limited now.  

 

 

 

Installation 

Before  installation,  check  that  the  local  distribution  conditions,  nature  of  gas  and  pressure,  and 
adjustment of the appliance are compatible. Make sure that the gas and gas line are clean. Install a gas 
filter and condensate trap before the heaters in case the gas or gas line is dirty or wet/oily. No guarantee 
can be given on heaters operating on a gas or gas line that is not dry and clean. 
 

Dimensions 

Physical dimensions of the appliances (rounded values) 

 

Length (cm) 

Width (cm) 

Height (cm) 

Weight (kg) 

AP-1-F 

35 

21 

17 

0,8 

AP-1-FT 

42 

21 

17 

1,1 

AP-2-F 

53 

29 

16 

1,4 

AP-2-FT 

60 

29 

16 

1,7 

AP-3-F 

35 

21 

17 

0,8 

AP-3-FT 

42 

21 

17 

1,1 

 

Place of installation 

The heaters are intended for use in well ventilated areas only. Do not install the heaters in situations 
that  are  not  well  ventilated.  See  also  below  for  more  ventilation  information.  Check  also  your  local 
regulations  for  the  ventilation  and  room  size  requirements.  The  number  of  heaters  per  building  is 
depending the type of building, the animals, the insulation, the climate and local wind conditions. Check 
with your installer or distributor for a heat transmission calculation to determine the number of heaters 
needed. 
 
Make sure that the place of installation is free of draft (less than 1 m/s). Too much draft will make the 
flames  unstable  and  will  result  in  a  lower  infra-red  heat  efficiency.  It  is  advisable  to  install  an  alarm 
system  that  reacts  on  temperature  in  case  a  temperature  drop  will  cause  damage.  Find  in  the  table 
below a rough guideline for the installation height to start with. Adjust afterwards to the height based on 
your personal preference and experience. 
 

Operational Distances 

AP-1 

AP-2 

AP-3 

To the ground 

60-100 cm 

125-160 cm 

75-120 cm 

Содержание AP-1 Series

Страница 1: ...infra red heaters for use in well ventilated areas Country of destination GB IE MT General international manual AP 1 AP 3 AP 2 AP 1 F AP 3 F AP 3 FT AP 2 F AP 2 FT Alke BV Industrielaan 11a 3925 BD S...

Страница 2: ...t so that nobody accidentally operates the heater Store the heater in a safe place mark that it cannot be used and contact a service agent or gas installer to solve the problem This heater has an open...

Страница 3: ...nature of gas and pressure and adjustment of the appliance are compatible Make sure that the gas and gas line are clean Install a gas filter and condensate trap before the heaters in case the gas or...

Страница 4: ...for more details Beside other important requirements this standard states in short that a 1 5 times room air replacement per hour is sufficient in most situations Also a maximum of 5W heat input per...

Страница 5: ...the gas supply to the burners to extinguish the flames In addition it makes it possible to remove the heaters after use or to service the heaters safely The gas inlet at the heater side is standard a...

Страница 6: ...and away from other people Check if there are no other operating heaters other gas heaters burning candles or people smoking cigarettes in the area Be sure that the valve on the gas cylinder is close...

Страница 7: ...ly one pressure is mentioned adjustment is not possible and only continuous operation or on off operation is allowed AP 1 2 3 FT version Make sure that the gas supply pressure remains constant at the...

Страница 8: ...r gas tightness with leak detection liquid or soapy water according the procedure in the standards applicable in the local installation situation Never use a flame for soundness checks In case a gas h...

Страница 9: ...he gas safety device are the most important parts that maybe requires replacement during normal operational life See the Parts List for more information Replacement thermocouple and magnet unit positi...

Страница 10: ...ing Wrong gas or pressure is used Check data plate with the gas supply Check if the injector or venturi are blocked or dirty Check the injector and venturi size with the table Check if pipe sizes or g...

Страница 11: ...2510000 Burner AP 3 50x80 mm 7 07009000 Distance ring 26 03856000 Suspension frame 155mm AP 2 8 01301000 Injector holder 27 013070xx Venturi 25x62 consult factory 9 01161xxx Injector M8x0 75 consult f...

Страница 12: ...x x I3P G31 1400 20 5 6 0 65 T 1 2 400 g h 0 47 0 22 10 5 1 0063CS3936 I3P G31 1400 20 4 6 0 55 329 g h 0 45 x 11 4 x Ha 1400m I3P G31 2000 20 5 4 0 5 T 1 4 386 g h 0 41 0 22 10 4 x x AP 3 series I2L...

Отзывы: