Alke AP-1 Series Скачать руководство пользователя страница 11

 

Version: April 2018

 

11 

manual number: 0009 0420EN

 

Parts list 

 

No. 

Part # 

Description 

No. 

Part # 

Description 

07000000 

End cap black PVC 

18 

07073000 

Blind rivet nut M4 

01327000 

Hose nipple 8mm 

19 

02456000 

Venturi gauze (flat) (AP-1, AP-3) 

01328000 

Hose nipple 8mm, smooth 

20 

03882000 

Clamping ring venturi 

00101010 

Gas safety device 1/8” 

21,29  00201000 

Thermocouple M8x320 

00106000 

Gas safety device w/hose nipple 

22 

02505000 

Burner AP-1 36x85mm 

01429000 

Reducing nipple 1/8”-3/8” 

23 

07060000 

Rivets 4,8x8,5 

0092xxxx 

Thermostat-consult factory 

24 

02350000 

Reflector (AP-1, AP-3) 

01405000 

Reducing ring 3/8”-1/8” 

25 

02510000 

Burner AP-3 50x80 mm 

07009000 

Distance ring 

26 

03856000 

Suspension frame 155mm (AP-2) 

01301000 

Injector holder 

27 

013070xx 

Venturi 25x62-consult factory 

01161xxx 

Injector M8x0,75

–consult factory 

28 

02459000 

Venturi gauze (ball) (AP-2) 

10 

02530000 

Dust filter small 

29 

00202000 

Thermocouple M8x450 (alternative) 

11 

08893130 

Venturi tube (complete) (AP-1, AP-3) 

30 

02516000 

Burner AP-2 61x210mm 

12 

07130000 

Screw SS M4x10 

31 

02351000 

Reflector Oval 

13 

03855000 

Suspension frame 120mm (AP-1, AP-3)  32 

02352000 

Reflector Square (not shown) 

14 

00158000 

Safety device nut M8x1 

33 

08893100 

Venturi tube (complete) 

15 

07135000 

Screw SS M5x10 

34 

07059000 

Rivets 4,8x8,8 SS Avinox 

16 

01799000 

Connection piece 25mm 

 

03903000 

Suspension hook AP1/AP2/AP3 

17 

013060xx 

Venturi 25x40

–consult factory 

 

00161000 

Magnet unit #53 (mini) 

 

Содержание AP-1 Series

Страница 1: ...infra red heaters for use in well ventilated areas Country of destination GB IE MT General international manual AP 1 AP 3 AP 2 AP 1 F AP 3 F AP 3 FT AP 2 F AP 2 FT Alke BV Industrielaan 11a 3925 BD S...

Страница 2: ...t so that nobody accidentally operates the heater Store the heater in a safe place mark that it cannot be used and contact a service agent or gas installer to solve the problem This heater has an open...

Страница 3: ...nature of gas and pressure and adjustment of the appliance are compatible Make sure that the gas and gas line are clean Install a gas filter and condensate trap before the heaters in case the gas or...

Страница 4: ...for more details Beside other important requirements this standard states in short that a 1 5 times room air replacement per hour is sufficient in most situations Also a maximum of 5W heat input per...

Страница 5: ...the gas supply to the burners to extinguish the flames In addition it makes it possible to remove the heaters after use or to service the heaters safely The gas inlet at the heater side is standard a...

Страница 6: ...and away from other people Check if there are no other operating heaters other gas heaters burning candles or people smoking cigarettes in the area Be sure that the valve on the gas cylinder is close...

Страница 7: ...ly one pressure is mentioned adjustment is not possible and only continuous operation or on off operation is allowed AP 1 2 3 FT version Make sure that the gas supply pressure remains constant at the...

Страница 8: ...r gas tightness with leak detection liquid or soapy water according the procedure in the standards applicable in the local installation situation Never use a flame for soundness checks In case a gas h...

Страница 9: ...he gas safety device are the most important parts that maybe requires replacement during normal operational life See the Parts List for more information Replacement thermocouple and magnet unit positi...

Страница 10: ...ing Wrong gas or pressure is used Check data plate with the gas supply Check if the injector or venturi are blocked or dirty Check the injector and venturi size with the table Check if pipe sizes or g...

Страница 11: ...2510000 Burner AP 3 50x80 mm 7 07009000 Distance ring 26 03856000 Suspension frame 155mm AP 2 8 01301000 Injector holder 27 013070xx Venturi 25x62 consult factory 9 01161xxx Injector M8x0 75 consult f...

Страница 12: ...x x I3P G31 1400 20 5 6 0 65 T 1 2 400 g h 0 47 0 22 10 5 1 0063CS3936 I3P G31 1400 20 4 6 0 55 329 g h 0 45 x 11 4 x Ha 1400m I3P G31 2000 20 5 4 0 5 T 1 4 386 g h 0 41 0 22 10 4 x x AP 3 series I2L...

Отзывы: