Alke AP-1 Series Скачать руководство пользователя страница 12

 

Version: April 2018

 

12 

manual number: 0009 0420EN

 

Technical table 

Category 

Gas 

Max. 

Supply 

press. 

Min. 

Supply 

press.** 

Max. 
Heat 
Input 

Min. 

Heat 

Input 

Gas 

consumption 

Main 

Injector 

(1x) 

By-pass 

injector 

T **(1x) 

Venturi 

Ring 

Injector 

Holder 

NOx 

class 

Remarks 

(-) 

(-) 

(mbar) 

(mbar)  (kW Hs) 

(kW Hs) 

(g/h or m3/h) 

(mm) 

(mm) 

(mm) 

(-) 

(-)  (-) 

AP-1 series

 

I2L, I2ELL 

G25 

50 

25 

1,3 

0,9 

0,15 m3/h 

0,71 

11 

I2H, I2E, I2ELL  G20 

50 

25 

0,95 

0,67 

0,09 m3/h 

0,55 

I3P 

G31 

200 

1,25 

0,19 

89 g/h 

0,36 

7,5 

I3P 

G31 

310 

25 

1,15 

0,3 

82 g/h 

0,32 

7,5 

I3P 

G31 

1400 

30 

1,1 

0,16 

(T=0,5)

 

79 g/h 

0,22 

0,16 

6,5 

0063CS3936 

Biogas 

75 

10 

1,0 

0,33 

0,18 m3/h 

0,75 

6,5 

AP-2 series

 

I2L, I2ELL 

G25 

50 

25 

3,5 

2,45 

0,39 m3/h 

1,15 

1,3 

13 

0063CS3936 

I2H, I2E, I2ELL  G20 

50 

25 

3,5 

2,45 

0,35 m3/h 

1,05 

1,2 

13 

0063CS3936 

I2H, I2E 

G20 

300 

10 

5,1 

0,9 

0,48 m3/h 

0,82 

0,34 

10,5 

0063CS3936 

I3B/P 

G30 

300 

5,3 

0,6 

385 g/h 

0,61 

0,22 

14 

I3P 

G31 

200 

4,8 

0,75 

345 g/h 

0,71 

14 

I3P 

G31 

300 

30 

5,0 

1,6 

360 g/h 

0,66 

0,39 

14 

0063CS3936 

I3P 

G31 

1000 

20 

5,7 

0,8 

410 gr/h 

0,52 

11 

I3P 

G31 

1400 

20 

5,6 

0,65 

(T=1,2)

 

400 g/h 

0,47 

0,22 

10 

0063CS3936 

I3P 

G31 

1400 

20 

4,6 

0,55 

329 g/h 

0,45 

11 

(Ha>1400m) 

I3P 

G31 

2000 

20 

5,4 

0,5 

(T=1,4)

 

386 g/h 

0,41 

0,22 

10 

AP-3 series

 

I2L, I2ELL 

G25 

50 

25 

1,6 

0,96 

0,18 m3/h 

0,82 

11 

I2H, I2E, I2ELL  G20 

50 

25 

1,6 

0,96 

0,15 m3/h 

0,74 

11 

I3P 

G31 

200 

100 

2,0 

1,55 

144 g/h 

0,47 

14 

I3P 

G31 

310 

25 

1,7 

0,48 

121 g/h 

0,39 

0,22 

11,5 

(ball gauze burner) 

I3P 

G31 

1400 

20 

1,95 

0,21

(T=0,75)

 

140 g/h 

0,27 

0,18 

7,5 

0063CS3936 

I3P 

G31 

1400 

20 

1,2 

0,15 

87 g/h 

0,23 

6,5 

(Ha>1400m) 

Biogas 

75 

10 

1,5 

0,5 

0,26 m3/h 

0,91 

7,5 

** In case the heater is equipped with a thermostat (T, Ti) with bypass injector the heater shall be operated on maximum supply pressure only. See also the 
pressure information on the data plate. Note that the minimum heat input with a thermostat is sometimes a bit higher than without thermostat. 
 
Conversion calculation from gross heat input kW(Hs) to nett heat input kW(Hi): 
Propane: divide gross heat input kW(Hs) by factor 1,09 (example: 1,20 kW(Hs) / 1,09 = 1,10 kW(Hi) 
Natural gas: divide gross heat input kW(Hs) by factor 1,11 (example: 1,20 kW(Hs) / 1,11 = 1,08 kW(Hi) 
 
G31 = propane; G20 = natural gas (100% methane); G25 = natural gas (86% methane); Biogas = 60% m 40% carbon dioxide 

Содержание AP-1 Series

Страница 1: ...infra red heaters for use in well ventilated areas Country of destination GB IE MT General international manual AP 1 AP 3 AP 2 AP 1 F AP 3 F AP 3 FT AP 2 F AP 2 FT Alke BV Industrielaan 11a 3925 BD S...

Страница 2: ...t so that nobody accidentally operates the heater Store the heater in a safe place mark that it cannot be used and contact a service agent or gas installer to solve the problem This heater has an open...

Страница 3: ...nature of gas and pressure and adjustment of the appliance are compatible Make sure that the gas and gas line are clean Install a gas filter and condensate trap before the heaters in case the gas or...

Страница 4: ...for more details Beside other important requirements this standard states in short that a 1 5 times room air replacement per hour is sufficient in most situations Also a maximum of 5W heat input per...

Страница 5: ...the gas supply to the burners to extinguish the flames In addition it makes it possible to remove the heaters after use or to service the heaters safely The gas inlet at the heater side is standard a...

Страница 6: ...and away from other people Check if there are no other operating heaters other gas heaters burning candles or people smoking cigarettes in the area Be sure that the valve on the gas cylinder is close...

Страница 7: ...ly one pressure is mentioned adjustment is not possible and only continuous operation or on off operation is allowed AP 1 2 3 FT version Make sure that the gas supply pressure remains constant at the...

Страница 8: ...r gas tightness with leak detection liquid or soapy water according the procedure in the standards applicable in the local installation situation Never use a flame for soundness checks In case a gas h...

Страница 9: ...he gas safety device are the most important parts that maybe requires replacement during normal operational life See the Parts List for more information Replacement thermocouple and magnet unit positi...

Страница 10: ...ing Wrong gas or pressure is used Check data plate with the gas supply Check if the injector or venturi are blocked or dirty Check the injector and venturi size with the table Check if pipe sizes or g...

Страница 11: ...2510000 Burner AP 3 50x80 mm 7 07009000 Distance ring 26 03856000 Suspension frame 155mm AP 2 8 01301000 Injector holder 27 013070xx Venturi 25x62 consult factory 9 01161xxx Injector M8x0 75 consult f...

Страница 12: ...x x I3P G31 1400 20 5 6 0 65 T 1 2 400 g h 0 47 0 22 10 5 1 0063CS3936 I3P G31 1400 20 4 6 0 55 329 g h 0 45 x 11 4 x Ha 1400m I3P G31 2000 20 5 4 0 5 T 1 4 386 g h 0 41 0 22 10 4 x x AP 3 series I2L...