Please check the apparatus before first use and after each of the first few uses to check all the fittings are 
securely fastened. Thereafter, it is important to follow a regular maintenance schedule by someone  
familiar with the equipment and record your maintenance checks. Equally inspection should be made 
immediately if any part appears not be operating correctly or something appears to be loose. Below  
follows a basic maintenance guide though our detailed maintenance guide and a sample maintenance 
log can be downloaded from 

https://align-pilates.com/pilates-equipment-resources/assembly-user-

guides/

• 

Springs

 - Inspect for signs of wear, look for deformation, kinks, gaps and corrosion. Springs showing 

signs of damage must not be used and must be replaced immediately. Springs must be replaced 
every 2 years or after 3,000 hours, whichever is first, or immediately if showing signs of fatigue or  
deformation 

• 

Foot Bar

 - check all allen bolts securing the padded bar to the aluminium arms and to the steel  

engagement bar and through the frame are tight

• 

Runners 

- ensure the runners are regularly cleaned and kept free from dirt as this is the main cause for 

a noisy reformer. If excess dirt is spotted on the runners then the wheels may also need cleaning. We  
recommend cleaning the runners with a window cleaner such as windowlene. 

• 

Ropes and Handles

 - check ropes for signs of wear, fraying or nicks and replace if damaged. Check 

stitching on handles is intact and handles are not overly worn.  

• 

PVC Upholstery

 - always ensure belts, jewellery and shoes are removed when working on the  

equipment as buckles, rings, watches and bangles can all end up damaging the upholstery. For 
cleaning upholstery we recommend cleaning with Gym Wipes from www.vital-clean.de,  which are  
available worldwide. For further information on cleaning recommendations see the link above. 

• 

Wheels 

- Remove the carriage and check for smooth rotation, if the wheels are not turning smoothly or 

are scarred or damaged this will impede smooth and quiet running of the equipment and the wheels 
need to be replaced. 

• 

Shoulder Rests 

- check the pads are securely bolted on to the metal frame - if loose retighten.

• 

Spring hooks 

- hand check that all eye hooks will not move. If loose remove, apply loctite and  

retighten. Check that the spring retention bungee is correctly attached.

• 

Nuts & Allen Bolts 

- check all nuts and bolts are tight, including those on the Silent rope pulley wheels 

and those securing the head rest.   

2. Troubleshooting Smooth Running of your A8-Pro Reformer

If you reformer is not running smoothly and quietly please follow these step in order to get it back up and 
running smoothly:

A. Check the reformer is level using a spirit level

B. Check the runners and wheels are clean and free from dirt and grit

C. Check the side wheels are correctly adjusted

D. Check the wheels and bearings are not damaged. If damaged replace. 

3. Removing the Carriage For Maintenance

From time to time you may need to remove the carriage either to deep clean the wheels & runners or to 
change the springs or wheels. Removing the carriage is easily done and no tools are required. To do this 
follow these steps

a) Remove shoulder rests, unlocking them first if they were locked
b) Remove the T bar that holds the ropes & place on the floor
c) Fold down the rope risers and rotate the pulleys so they are flat and pointing towards the runner
d) Remove the two carriage stoppers at the open end of the runner - these can be unscrewed by hand
e) Now gently slide the carriage out

Remember when putting the carriage back in to be careful not to damage the wheels when inserting 
them in to the runner - this job is best done by two people. 

Periodic Maintenance, Care & Safety Checks

Содержание A8-ProReformer

Страница 1: ...this manual please visit https align pilates com pilates equipment resources assembly user guides For Patents Patents Pending see www Align Pilates com Patents IP A8 Pro with standard Legs and optional Gondola Pole Planking handles A8 Pro with standard Legs and optional Gondola Pole ...

Страница 2: ...er hooks for a roll up pole or Gondola pole available separately ISO20957 1 Class S Item Max User Weight 150kg Suitable for users 145cm 193cm 4 10 6 8 Dimensions Reformer only 235 L x 66 W x 24cm H Reformer with Standard Leg Extensions 235 x 66 x 42cm Weight Approx 75kg depending on the leg configuration Assembly Rope Riser Locking Knob Adjustable Foot Rope Riser Rope Height Adjustment Knob Extra ...

Страница 3: ...use the legs with the wheels attached in this position and attach them with the wheels facing away from the reformer as shown in the Reformer Map The wheeled legs can be attached on either end though particularly when a half Cadillac is attached the wheels are best attached to the standing platform end Whilst the frame is supported place the legs in position For the Standard and Rehab legs the Lon...

Страница 4: ...ntly slide the carriage in to the runners with the springs pointing towards the standing platform After attaching at least one spring roll the carriage back and forward checking that the carriage runs freely for the whole length of the runner There should be no squeaking or interference from the side wheels if there is the side wheels need to be moved inwards Conversely there should not be excessi...

Страница 5: ...il through the pulley from the top and put the rope eyelet where you attached the handles over the rope holder pole Next pull the rope adjusting T bar all the way out as in Fig 20 The T bar position is changed by loosening the knob and then pulling back to disengage the locking pin so that the bar can be slid back or forward Now put the spring bar in position 1 Fig 21 and thread each rope tail thr...

Страница 6: ... pin storage slot Fig 22 b If lowering the bar it is best to slightly lift the foot bar towards you with one hand whilst using your other hand to hold the foot bar adjustment arm to smoothly guide it to the next lower or desired position c If putting the foot bar in the flat position be sure not to stand on the bar in this position as this can damage the bar Note always check the bar is secure bef...

Страница 7: ...ign of deformation or damage and cease using immediately 6 Ensuring your reformer is level It is important to check your reformer is level to ensure it runs smoothly particularly where the floor is not perfectly flat Once you have positioned your reformer in the location where you intend to use it place a spirit level on each runner to check it is horizontal If it is not you can screw in or out or...

Страница 8: ... which are available worldwide For further information on cleaning recommendations see the link above Wheels Remove the carriage and check for smooth rotation if the wheels are not turning smoothly or are scarred or damaged this will impede smooth and quiet running of the equipment and the wheels need to be replaced Shoulder Rests check the pads are securely bolted on to the metal frame if loose r...

Страница 9: ...own off the standing platform 4 Use your reformer in a clear space with at least 1m of space all around the machine This equipment is for indoor use only on a firm and flat surface 5 When using a reformer less is often more remember when performing certain exercises less spring resistance makes the exercise more challenging 6 Before starting any exercise routine consult a physician 7 Before any ne...

Страница 10: ...10 Exploded diagrams Note For larger images of the exploded diagrams and a detailed parts list please download from https align pilates com pilates equipment resources assembly user guides ...

Страница 11: ...four different directions and they can lock at 4 differ ent heights in each of the directions offering a total of 16 different positions for a range of alternative exercise options Sitting Box Jump Board Optional Extras Half Cadillac Tower Mattress Insert Platform Extender 6 Maple Gondola Pole The reformer has hooks under the frame to hold a Gondola Pole which is available separately Note on A Ser...

Страница 12: ...all springs excepting that a decrease of 5 of the spring power per 1 500 hours usage is acceptable according to internationally standards Align Pilates Springs should be replaced after a maximum of 3 000 hours use or 2 years whichever is earlier In the event of any signs of damage or wear springs should be replaced immediately regardless of age or usage 6 Upholstery The upholstery fabric on Align ...

Отзывы: