SECTION 5: OSD MENU REFERENCE
3.
Configure the alarm input.
a.
Move the cursor to
ALARM INPUT
, then click the
IRIS+
to enter edit mode.
b.
Click the up and down direction buttons to set the input status. You can configure it as
OPEN
(normally open),
CLOSE
(normally closed) or
OFF
(disable the alarm input).
—
OPEN
: If you set the status as
OPEN
, alarm will be triggered by a closed circuit between the alarm input and
alarm ground.
—
CLOSE
: If you set the status as
CLOSE
, alarm will be triggered by open circuit between the alarm input and
alarm ground.
—
OFF
: If you set the status as
OFF
, it will not be triggered.
c.
Click
IRIS+
again to confirm your selection.
4.
Configure the alarm linkage action.
You can specify the linked action when an alarm occurs. On the
ALARM AC
parameter, you can set the alarm action as preset
from 1 to 8, pattern from 1 to 4, patrol from 1 to 8, panning scan, tilting scan, random scan, frame scan, panoramic scan, day
mode, night mode or none. You can also set the alarm output for the alarm. See “4.17.3 Configuring auxiliary alarm output”
on page 76 for more information.
5.
Configure alarm priority. Open the PRIORITY menu and set the alarm priority as HIGH, MID or LOW.
If multiple alarms with different priorities are triggered at the same time, the dome only responds to the alarm with the
highest priority. If multiple alarms with the same priority are triggered at the same time, then the dome will respond to each
alarm according to the defined alarm sequence.
5.3.2 Configuring alarm parameters
You can set the alarm related parameters including the linkage action interval, alarm duration and dome activity resumption.
1.
Open the alarm parameter configuration menu. Go to
MAIN MENUS
g
DOME SETTINGS
g
ALARMS
g
ALARM
SETTING