EU marking description
CE Conformity Marking:
CE
(2460)
Identification
Number of Notified
Body involved in production control stage:
2460
Explosion Protection marking:
Equipment Group:
-/II
Equipment Category:
2 G
The equipment is intended for Zone 1 and Zone 2. The space inside the process vessel and process
lines are considered as non-hazardous area therefore (-/II) in the marking code.
Equipment Category Definition
EU
Category
Equipment
Group
Typical Zone of
application
Gas atmospheres "high level of
protection"
2G
II
1
Gas atmospheres "normal level of
protection"
3G
2
No Ex protection.
-
-
Out of hazardous zone
Specific Conditions of Use
“X” - The flameproof joints not intended to be repaired.
“X” – Ambient temperature -20ºC to +60ºC
“X” – Minimum yield stress of the fastening screws used for enclosure is 646 MPa.
“X” – To avoid potential electrostatic charging hazard, always use a damp cloth for cleaning the
insulation jacket. Avoid dry rubbing of the insulation jacket.
“X” – The cable glands provided are suitable only for fixed applications and the cable must be
effectively clamped and cleated to prevent pulling and twisting.
Applicable
Standards
EN 60079-0:2012/A11:2013 (IEC 60079-0 ed.6.0)
EN 60079-1:2014 (IEC 60079-1 ed.7.0)
EN 60079-18:2008 (IEC 60079-18 ed. 4.0)
Содержание TORREXX TX240
Страница 9: ...ASDI Operations and Maintenance TX Models P N 54629 1 2 Figure 1 TORREXX SSR Dimensional Drawing ...
Страница 52: ...APPENDIX A TECHNICAL INFORMATION ...
Страница 59: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 80: ...ASCO Valve used by Algas SDI ...
Страница 82: ......
Страница 83: ......
Страница 84: ......
Страница 85: ......