ASDI
Operations and Maintenance – TX Models – P/N: 54629
6-32
TREE # 2B
Liqui-SAFE VALVE DOES NOT TRIP
GREEN
IS RELAY
LATCHED?
CHECK FUSE LINKS
FUSE LINKS
OPEN?
REPLACE OPEN
FUSE LINKS.
CONTACT ASDI
YES
NO
CHECK FOR LOOSE
WIRING
YES
NO
PRESS HI-LIMIT
BUTTON TO RESET
VAPORIZER
STARTS
WORKING?
CHECK:
1. IF THERMOCOUPLE
CONNECTION TO CONTROL
BOARD IS LOOSE
2. CHECK THERMAL GREASE
COATS LAST 2 INCHES OF
THERMOCOUPLE TIP WHEN
REMOVED FROM
THERMOWELL
3. CHECK THERMOCOUPLE IS
FULLY INSERTED IN THE
THERMOWELL. WHEN FULLY
INSERTED THERMOCOUPLE
SHOULD BOTTOM OUT IN THE
THERMOWELL AND
THERMOCOUPLE SHEATHING
SHOULD COMPRESS TO
SECURE BAYONETT FITTING
4. REMOVE DRAIN PLUG AND
CHECK FOR HEAVY ENDS
IF THE ABOVE ACTIONS DO
NOT FIX THE PROBLEM THEN
REPLACE TEMPERATURE
CONTROLLER BOARD.
CHECK IF THERE
IS 24V AT THE
RELAY LEADING
TO THE
TEMPERATURE
CONTROLLER
NO
YES
24V AT THE
RELAY?
YES
REPLACE RELAY
IS THERE A
LOOSE WIRE?
TIGHTEN WIRES.
RESTART
VAPORIZER.
SEE HEATER CORE
RESISTANCE ON
PAGE 6-37.
SERVICE INLET
SOLENOID WITH
SERVICING KIT (SEE
SPARE PARTS LIST).
NO
YES
NO
REPLACE
THERMOCOUPLE
Содержание TORREXX TX240
Страница 9: ...ASDI Operations and Maintenance TX Models P N 54629 1 2 Figure 1 TORREXX SSR Dimensional Drawing ...
Страница 52: ...APPENDIX A TECHNICAL INFORMATION ...
Страница 59: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 80: ...ASCO Valve used by Algas SDI ...
Страница 82: ......
Страница 83: ......
Страница 84: ......
Страница 85: ......