Make sure the ash bins are properly positioned during product operation.
Any unauthorized modification of the product is prohibited.
Use only spare parts recommended by the manufacturer.
The first ignition
Pay special attention to the cleaning of the firebox before starting the ignition phase and make sure that the plate below the firebox is
properlyFASTENED.
The proper function of the device is possible when there is no uncontrolled air intake, so the door HAS TO be tightly closedand all other
routes should be sealed except the one predicted. It is recommended to check if the door seal is well compressed along the door closure line.
The EN14785 regulation for installation of the product on pelletprescribes necessary vacuum of 10 Pa at the base of the exhaust flue pipeand
for this reason special attention has to be paid to the smoke discharge system. The lower and more winding exhaust pipe causes air flow required
for combustion (which can change and influence the combustion itself) to be also lower. Slow exhaust gas flow, in some cases, can
provoketemperature increase which creates the modulation of the operation power.
Since there are different types of pellets on the market the product operation has to be adjusted to the certain type of fuel to be used.
In order to provide customers a chance to adjust their stoveto different types of pelletand different types of installation the User menu contains
four recopies, ascending from 1 to 4. By increasing the recipeidentification code the system ventilation is increasing too. If in the end, none of the
recipes produces efficient combustion, bear in mind that the operative parameters can be changed ONLY with the help of specialized technicians
from the Alfa Plam Company, who will analyze the situation and offer the best solution.
In order to properly heat the system it is recommended to adjust the product power to values4 or 5 during ignition phase and a few
minutes after.
As an additional user assistance, below you can find the order of steps needed to turn on the product:
1)
Make sure the system is properly filled with water;
2)
Fill the hopper with the appropriate amount of fuel.We recommend not to fill the hopper to the maximum, optimal level is reached by
loading fuel until it reaches the panel with circular holes inside the hopper;
3)
Plug in the product to the power supply;
4)
Press the switch at the rear side of the stove;
5)
Fill in the auger by pressing and holding the key
Manual pellet input
’’ (
Menu
) in order to activate the manual load procedure by
activating the continuesmode of the auger motor. The lower display shows
Load
, while the upper shows the elapsed input time. In order to interrupt
the load, press the button. Loading is automatically interrupted after 300 seconds.
ATTENTION: The system has to be in OFF operation modeto perform this operation.
ATTENTION: It is necessary to repeat the loading of the auger every time the hopper is empty.
6)
Empty the firebox;
7)
In order to switch on the stove, hold ignition key for a few seconds. The stove will initiate the check up and ignition phase,completely
independently,the way the system demands it. During check up errors might appear that will prevent the stove to ignite.
ATTENTION: If the ignition process fails, repeat the operation in order to empty the firebox. Neglecting this repetition leads to
higher risk of over combustion which ejects too much smoke into the environment.
ATTENTION: DO NOT, under any circumstances, put your hand into the augur to load pellet while the boiler is active.
ATTENTION: Do not open the door or plug the device out of power supply, even when there is a blockage or fuel accumulation in the
firebox.Start the extinguishing process andresolve the problembefore new ignition procedure.
ATTENTION: The stove can operate only when the heating installation is connected and filled with water. Use of the device without
fulfilling these conditions may damage the product severely. In such case the warranty is void.
ATTENTION: The heating installation must be filled with water and under pressure of at least 1.2 bars when the temperatures are
low. Also check for air bubbles that can enter the pump and provoke a blockage. For proper function of the device and heating it is necessary to
eject the air out of the heating installation.
This activity must be regularly performed by authorized and trained personnel.
PRODUCT EXTINGUISHING
Press and hold the
Ignition
key for few seconds. The stove will start the extinguishing process as predicted in the plan phase (the time of
extinguishing may vary and it could take up to few minutes).
ATTENTION: We do not recommend the extinguishing process interruptionbefore it is finished, for example, by plugging out the
power cord.
If the flame is out due to pellet deficit, turn off the stove. When the stove is extinguished add more fuel in the hopper in order to
start a new ignition process.
DO NOT load pellet into firebox by hand.
ATTENTION: While the device is operating, the door must be closed.It is allowed to open them only for maintenance when the
product is cold.
It is forbidden to make any changes on the device.
Self-initative reconstruction of the product, use of non original spare parts,or unauthorizedchange of product partsandwarranty
annulment can lead to failures and severely endanger the safety of those directly operating the device.
ATTENTION: While using the device, avoid blocking the ventilation holes that enable the continuous combustion air flow and air
vents on the backside of the product.
Safety devices
The product is equipped with the following safety devices:
-
Probe for measuring smoke temperature: this component allows you to read flue gas temperatureand constant monitoring of the
product operation;
-
Thermostat with manual controls for detection of excessive water temperature in the boiler. If it is reached, the product must be
unblocked by pressing the safety button located at the rear side of the product;