10 

  Make sure the ash bins are properly positioned during product operation. 

  Any unauthorized modification of the product is prohibited. 

  Use only spare parts recommended by the manufacturer. 

 

 

The first ignition 

Pay  special  attention  to  the  cleaning  of  the  firebox  before  starting  the  ignition  phase  and  make  sure  that  the  plate  below  the  firebox  is 

properlyFASTENED. 

The proper function of the device is possible when there is no uncontrolled air intake, so the door HAS TO be tightly closedand all other 

routes should be sealed except the one predicted. It is recommended to check if the door seal is well compressed along the door closure line. 

The EN14785 regulation for installation of the product on pelletprescribes necessary vacuum of 10 Pa at the base of the exhaust flue pipeand 

for this reason special attention has to be paid to the smoke discharge system. The lower and more winding exhaust pipe causes air flow required 
for  combustion    (which  can  change  and  influence  the  combustion  itself)  to  be  also  lower.  Slow  exhaust  gas  flow,  in  some  cases,  can 
provoketemperature increase which creates the modulation of the operation power. 

Since there are different types of pellets on the market the product operation has to be adjusted to the certain type of fuel to be used. 
In order to provide customers a chance to adjust their stoveto different types of pelletand different types of installation the User menu contains 

four recopies, ascending from 1 to 4. By increasing the recipeidentification code the system ventilation is increasing too. If in the end, none of the 
recipes produces efficient combustion, bear in mind that the operative parameters can be changed ONLY with the help of specialized technicians 
from the Alfa Plam Company, who will analyze the situation and offer the best solution. 

 

In order to properly heat the system it is recommended to adjust the product power to values4 or 5 during ignition phase and a few 

minutes after. 

As an additional user assistance, below you can find the order of steps needed to turn on the product: 
1)

 

Make sure the system is properly filled with water; 

2)

 

Fill the hopper with the appropriate amount of fuel.We recommend not to fill the hopper to the maximum, optimal level is reached by 

loading fuel until it reaches the panel with circular holes inside the hopper; 

3)

 

Plug in the product to the power supply; 

4)

 

Press the switch at the rear side of the stove; 

5)

 

Fill in the auger by pressing and holding the key 

Manual pellet input

’’ (

Menu

) in order to activate the manual load procedure by 

activating the continuesmode of the auger motor. The lower display shows 

Load

, while the upper shows the elapsed input time. In order to interrupt 

the load, press the button. Loading is automatically interrupted after 300 seconds. 

  ATTENTION: The system has to be in OFF operation modeto perform this operation. 
 

ATTENTION: It is necessary to repeat the loading of the auger every time the hopper is empty. 

6)

 

Empty the firebox; 

7)

 

In order to switch on the stove, hold ignition key for a few seconds. The stove will initiate the check up and ignition phase,completely 

independently,the way the system demands it. During check up errors might appear that will prevent the stove to ignite. 

 

ATTENTION: If the ignition process fails, repeat the operation in order to empty the firebox. Neglecting this repetition leads to 

higher risk of over combustion which ejects too much smoke into the environment. 

  ATTENTION: DO NOT, under any circumstances, put your hand into the augur to load pellet while the boiler is active. 
ATTENTION: Do not open the door or plug the device out of power supply, even when there is a blockage or fuel accumulation in the 

firebox.Start the extinguishing process andresolve the problembefore new ignition procedure. 

 

ATTENTION: The stove can operate only when the heating installation is connected and filled with water. Use of the device without 

fulfilling these conditions may damage the product severely. In such case the warranty is void. 

  ATTENTION: The heating installation must be filled with water and under pressure of at least 1.2 bars when the temperatures are 

low. Also check for air bubbles that can enter the pump and provoke a blockage. For proper function of the device and heating it is necessary to 
eject the air out of the heating installation.

This activity must be regularly performed by authorized and trained personnel. 

PRODUCT EXTINGUISHING

 

Press and hold the 

Ignition

 key for few seconds. The stove will start the extinguishing process as predicted in the plan phase (the time of 

extinguishing may vary and it could take up to few minutes). 

  ATTENTION: We do not recommend the extinguishing process interruptionbefore it is finished, for example, by plugging out the 

power cord. 

  If the flame is out due to pellet deficit, turn off the stove. When the stove is extinguished add more fuel in the hopper in order to 

start a new ignition process. 

  DO NOT load pellet into firebox by hand. 

 

ATTENTION: While the device is operating, the door must be closed.It is allowed to open them only for maintenance when the 

product is cold. 

 

It is forbidden to make any changes on the device. 

 

Self-initative  reconstruction  of  the  product,  use  of  non  original  spare  parts,or  unauthorizedchange  of  product  partsandwarranty 

annulment can lead to failures and severely endanger the safety of those directly operating the device. 

 

ATTENTION: While using the device, avoid blocking the ventilation holes that enable the continuous combustion air flow and air 

vents on the backside of the product. 

 

 

Safety devices 

The product is equipped with the following safety devices: 

Probe for measuring smoke temperature: this component allows you to read flue gas temperatureand constant monitoring of the 

product operation; 

Thermostat with manual controls for detection of excessive water temperature in the boiler. If it is reached, the product must be 

unblocked by pressing the safety button located at the rear side of the product; 

Содержание CFH XILA

Страница 1: ...METALNA INDUSTRIJA AD 17500 VRANJE SRBIJA Radni ka 1 Tel 017 421 121 INSTALLATION USE AND MAINTAINANCE MANUAL CFH XILA ENG_v 1 0...

Страница 2: ...ning or operation should be carried out only by qualified personnel Do not use any flammable liquids for ignition process This unit must not be used by people including children with limited physical...

Страница 3: ...devices 10 Control panel 11 KEYS 11 LED 11 DISPLAY 12 MENU 12 User menu 1 13 DISPLAYS 13 SETTING PRODUCT POWER 13 MANUAL PELLET LOAD 13 PELLET FEEDER MODIFICATION 13 COMBUSTION FAN MODIFICATION 14 EN...

Страница 4: ...essingin order to optimize the painting process and improve the final result Gaskets which make combustion chamber air impermeable They must be checked periodically to prevent the improper combustion...

Страница 5: ...2 TOP A Exhaust gases pipe diameter 80 Dimensionsin mm B 3 4 Unit inflow pipe C 1 Unit return pipe D Air intake 50 Details...

Страница 6: ...2 7 Heating power to water kW 14 5 4 7 Heating power to ambience kW 3 5 1 4 Efficiency 93 4 95 7 Emissions of CO with 13 of oxygen 0 0131 0 0074 Combustion gas temperature C 126 67 Gas mass flow g s 1...

Страница 7: ...value of this fuel LHV 4100 5000 kcal kg Wood pellet used as fuel must have excellent qualitative characteristics such as defined in standards DIN 51731 ONORM M 7135 and EN plus A1 Example of basic d...

Страница 8: ...ood pellet accumulates in the combustion chamber while the unit is operational switch off the unit and switch it on with the greater ventilation program If the pellet is still accumulating try a diffe...

Страница 9: ...stancefrom combustible material cm ATTENTION After selection of the unit location it is possible to modify unit s height by tilting it sideways and unscrewing legs to reach the proper space from the b...

Страница 10: ...certain number of indications that point out the standard for this type of system configuration Always make sure there is an inspection opening I which will enable regular cleaning activities and remo...

Страница 11: ...e separated from the outer part of the chimney Figure 2 6 Exampleconnection to the chimney In case of fire in the chimney or exhaust pipe immediately switch off the unit and disconnect it from the pow...

Страница 12: ...onnect the power cable to the household powerline and press ON button on the rear side of the unit At the beginning of use unpleasant fumes and odors may occur originating from painted part These inco...

Страница 13: ...repeat the loading of the auger every time the hopper is empty 6 Empty the firebox 7 In order to switch on the stove hold ignition key for a few seconds The stove will initiate the check up and igniti...

Страница 14: ...ossible for one or more sensors to be interrupted or short circuited This will be detected during the check up phase The failure of these probes could lead to ignition failure continued state of modul...

Страница 15: ...o high temperature of flue gases Er07 Encoder error No signal Er08 Encoder error Unable to adjust number of revolutions Er09 Low water pressure Er10 High water pressure Er11 Error due to problems with...

Страница 16: ...St Winter InU mode FC Firmware code and revision FYSD01000114 00 00 product without two way radio FYSD01000102 00 00 product with two way radio 395 Manufacturer production code 0Y 0X N B If the value...

Страница 17: ...t value default value is 0 After 3 seconds value is stored and the display returns to normal ENABLING CHRONO FUNCTION This sub menu allows activation deactivationof chromo programmingmode Press and ho...

Страница 18: ...y for the technical assistance network LEAr Remote control code learning menu Only if the product has two way radio option User menu 2 settingsare shown in the upper display Press K1 key to exit User...

Страница 19: ...reach wanted sub menuand pressK5key Gio r n 2 PressK3 K7 keys to select one of three possible programming options _ _ _ _ 1I Mo 3 Press and holdK4 key for3 seconds 00 00 1 Mo 4 Choose the start up tim...

Страница 20: ...turn toUser menu 2 settings pressK1key SYSTEM MENU This menu allows access toSystem menu The upper display showstPAr ATTENTION This menu cannot be accessed because it is only for the technical assista...

Страница 21: ...ply Preporu uje se da o istite zone opisane iznad pomo u etke koju dobijete sa ure ajem ili usisiva a PA NJA na svakih 3 4 dana obavezno o istite dimne cevi u kotlu Otvorite vrata komore i specijalnom...

Страница 22: ...in two ways switching off the rear side power keyor pulling out the power cord from the socket either the wall socket or stove rear side connection plug In case the maintenance operations described i...

Страница 23: ...and reset timers by unscrewingtwospark plugs at the back of the unitand pressing both buttons Check air intake opening for blockages Too high environment temperature insufficient temperature reduction...

Страница 24: ...ine to shut down and then press and hold ON key for 3 seconds Check the water pressure level in the system Faulty probe Contact service Er11 Clock error Problemswith the internal clock Press and hold...

Страница 25: ...t down and then press and hold ON key for 3 seconds Check the primary air openings Check soiling and draft of flue gas pipe Contact service ATTENTION If the recommended solutions fail to remove the pr...

Страница 26: ...the content of this Manual Any complete or partial reproduction of the Manual without the Company s written approval is strictly forbidden Offenders will be prosecuted All data and measures are provid...

Отзывы: