13
Control panel menu consists of a user menu that allows end users to operate the stove regarding their needsand a secret menu that allows
authorized personnel to modify operation parameters, perform operation tests of outputs and check operation history of the system.
User menu 1
User menu 1 consists of sub-menus for quick accessand displays where you can see and modify some parameters.
DISP LAYS
This is a display sub-menu showing values of some parameters.
Click
K8
key to open
Display
sub-menu
.
If you continue to press
K8
key, lower display shows specific parameter while upper shows specific parameter value.
Possible displays are listed in the table.
DISPLAY
PARAMETER
tA
Room temperature
tP
Pump temperature (visible only if thermostat exists)
tF
Smoke temperature
UF
Oxidation fan speed [RPM/Volt]
FUnC
Summer(ESt)/Winter(InU) mode
FC
Firmware code and revision: FYSD01000114.00.00 (product without two-way radio)
FYSD01000102.00.00 (product with two-way radio)
395
Manufacturer production code: 0Y.0X
N.B:
If the value of the displayed parameter consists of a large number of characterscontinue to pressK8 key to see the entire value.
SETTI NG PRODUCT POWER
This sub-menu allows the power change of the device
Click
K2/K6
key: lower left display blinks.
Successive clicks can change the power according to available values. For example: 1–2–3–4–5–A (A = Automaticcombustion). After 3
seconds the value is stored and the display returns to normal.
M ANUAL PELLET LO AD
This sub-menu allowsactivation of manual pellet load process.
Press and hold
K5
key, manual load procedure is activatedwith continuous activation of the auger motor.
The lower display shows
LoAd
and upper showselapsed load time. To stop loadingpress any key. Loading is automatically stopped after
300 seconds.
PELLE T F EEDER M ODIFICA TIO N
This sub-menu allows pellet feeder modification.