Technical Manual
– Color Tester
36
TROUBLE SHOOTING
EN
ERROR
CODES
ERROR
DETECTED
ERROR
DESCRIPTION
TROUBLESHOOTING
49-50
PLUG_COVER_”X”_IDX, where “X”=1..2
Slave “X” CAPPING STATION
communication time-out
(detected on the MAB side)
Check the SCCB power supply wiring and
replace it if damaged. Check the RS485
communication connector, and visually
check the board hardware. If damaged,
replace the "X" CAPPING board
51
AUTOCAP_IDX
Slave AUTOCAP
communication time-out
(detected on the MAB side)
Check the SCCB power supply wiring and
replace it if damaged. Check the RS485
communication connector, and visually
check the board hardware. If damaged,
replace the AUTOCAP slave board
59
TIMEOUT_COM_MAB_MGB
MAB-MGB Communication time-
out
Check MAB and MGB power supply wiring
and replace it if damaged. Check the
SERIAL communication connectors, and
visually check the hardware of the 2 boards
61-68
B”X”_BASE_TOUT_ERROR, where “X” =
1..8
"X" BASE slave communication
time-out (detected on the
SLAVE side)
Check the SCCB power supply wiring and
replace it if damaged. Check the RS485
communication connector, and visually
check the board hardware. If damaged,
replace the ”X” BASE slave board
69-92
C”X”_COLOR_TOUT_ERROR, where “X” =
1..24
"X" COLORANT slave
communication time-out
(detected on the SLAVE side)
Check the SCCB power supply wiring and
replace it if damaged. Check the RS485
communication connector, and visually
check the board hardware. If damaged,
replace the ”X” COLORANT Slave board
93
MOVE_X_AXIS_TOUT_ERROR
X AXIS slave communication
time-out (detected on the
SLAVE side)
Check the SCCB power supply wiring and
replace it if damaged. Check the RS485
communication connector, and visually check
the board hardware. If damaged, replace the X
AXIS board
94
MOVE_Y_AXIS_TOUT_ERROR
Y AXIS slave communication
time-out (detected on the
SLAVE side)
Check the SCCB power supply wiring and
replace it if damaged. Check the RS485
communication connector, and visually check
the board hardware. If damaged, replace the Y
AXIS board
95-98
STORAGE_CONTAINER”X”_TOUT_ERRO
R, where “X”=1..4
“X” CAN SELECTION slave
communication time-out
(detected on the SLAVE side)
Check the SCCB power supply wiring and
replace it if damaged. Check the RS485
communication connector, and visually
check the board hardware. If damaged,
replace the ”X” CAN Slave board
99-100
PLUG_COVER”X”_TOUT_ERROR, where
“X”=1..2
“X” CAPPING STATION slave
communication time-out
(detected on the SLAVE side)
Check the SCCB power supply wiring and
replace it if damaged. Check the RS485
communication connector, and visually
check the board hardware. If damaged,
replace the ”X” CAPPING slave board
101
AUTOCAP_TOUT_ERROR
AUTOCAP slave communication
time-out (detected on the
SLAVE side)
Check the SCCB power supply wiring and
replace it if damaged. Check the RS485
communication connector, and visually
check the board hardware. If damaged,
replace the AUTOCAP slave board
Содержание Color Tester
Страница 26: ...Technical Manual Color Tester 26 CONNECTION DIAGRAMS EN 8 CONNECTION DIAGRAMS...
Страница 27: ...Technical Manual Color Tester EN TROUBLE SHOOTING 27...
Страница 28: ...Technical Manual Color Tester 28 CONNECTION DIAGRAMS EN...
Страница 29: ...Technical Manual Color Tester EN TROUBLE SHOOTING 29...
Страница 30: ...Technical Manual Color Tester 30 CONNECTION DIAGRAMS EN...
Страница 31: ...Technical Manual Color Tester EN TROUBLE SHOOTING 31...
Страница 32: ...Technical Manual Color Tester 32 CONNECTION DIAGRAMS EN...
Страница 33: ...Technical Manual Color Tester EN TROUBLE SHOOTING 33...
Страница 34: ...Technical Manual Color Tester 34 CONNECTION DIAGRAMS EN...
Страница 44: ...Technical Manual Color Tester 44 TROUBLE SHOOTING EN Page left intentionally blank...