6 Technical data
It is important to observe the technical data during installation, operation and maintenance.
Inform personnel about the technical data.
6.5
Noise emission
Pump type
Sound pressure level (dBA)
LKHex-10
69
LKHex-15
72
LKHex-20
70
LKHex-25
74
LKHex-35
71
LKHex-40
75
LKHex-45
70
LKHex-50
75
LKHex-60
77
LKHex-70
88
The above LKH noise levels are the same for LKHPF, LKHI, LKH UltraPure, LKH Evap and LKHex.
The above SolidC noise levels are the same for SolidC UltraPure.
The noise measurements are carried out using the original motor and shroud, at the approximate Best Efficiency Point (BEP)
with water at ambient temperature and at 50Hz.
Very often, the noise level generated by the flow through the process system (e.g. valves, pipes, tanks etc.) is much higher than
that generated by the pump itself. Therefore, it is important to consider the noise level from the total system and take the
necessary precautions with regard to personal safety if required.