5 Maintenance
Read the instructions carefully. The items refer to the parts list and service kits section.
Handle scrap correctly.
: Relates to the shaft seal.
5.4
Assembly of pump/single shaft seal
NOTE: If fitting SiC/SiC single seal, the static seal face must be marked “LKH Prime”.
Step 1
1. Remove spring (13)
NOTE!
Make sure that O-ring (15) has maximum clearance from the
sealing surface.
Step 2
1. Refit spring (13) on rotating seal ring (14)
2. Fit the spring and the rotating seal ring on drive ring (10)
CAUTION
Ensure that the driver on the drive ring is inserted into the notch
in the rotating seal ring.
Step 3
Fit the complete shaft seal on the stub shaft (7).
NOTE!
Make sure that the Connex pin (8) on the stub shaft is inserted into
the notch in the drive ring (10).