![Alfa IN PEGAS 160 PLASMA Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/alfa-in/pegas-160-plasma/pegas-160-plasma_operating-manual_2894877007.webp)
7/21
ALFA IN a.s
©
www.alfain.eu
3
operations and consulting the manufacturers.
2.2 PROTECTIVE UTTILITIES
1. Welding helmet with filter shade at least 10
2. Welding gloves
3. Welding apron and cloth
4. Welding boots
2.3 RISK OVERVIEW
1. Risk of electric shock.
2. Ultraviolet light and light radiation
3. Risk of inhaling gas fumes and dust particles
4. Burns
5. Noise
NOTE
1.
It is forbidden to operate a machine with damaged insulation of the
cutting torch or supply cable.
2. Never operate the machine taken down or damaged covers.
3.
It is forbidden to operate the machine in wet environments and outdoors
in rain or snow.
4.
Ensure proper grounding clamping pliers, which also reduces the risk of
electric shock.
5.
Use prescribed protective utilities, keep them dry.
6.
Plasma arc cutting produces intense electric and magnetic emissions that
may interfere with the proper function of cardiac pacemakers, hearing
aids, or other electronic health equipment. Persons who work near
plasma arc cutting applications should consult their medical health
professional and the manufacturer of the health equipment to determine
whether a hazard exists.
7.
Never aim the torch against the eyes, body or other person.
3.
CONDITIONS OF USE
1. This equipment must only be used by qualified personnel.
2. During installation, any electric work must only be carried out by trained
personnel.
3. Do not expose the plasma machine to direct sunlight or to rain or snow. This
equipment conforms to protection rating IP23S.
4. Place the machine the way that the cooling air can enter the vents without
restriction to. It is necessary to ensure that no impurities, especially metal
particles, are not drawn into the machine.
5. Cutting machine in terms of interference suppression is intended primarily
for industrial premises. In the case of use of other areas may be need for