background image

6

INSTALLATION

     Install the portable  air conditioner in a flat and spacious location
     where the air outlets will not be covered up. A minimum 
     clearance of 11.8in from a wall or other obstacles should 
     be kept. The air conditioner  shall not be used in the laundry. 
     The plug shall accessible while the air conditioner is being operated. 
     

1   Important:

2   DUCT MOUNT INSTRUCTIONS:

Exhaust Air Oulet

Duck

A)  TEMPORARY-

     1.  Attach one end of the duct to the exhaust air outlet of the 
          mobile air conditioner, first fit the left side of the duct on the
          exhaust air panel, then the right side duct. Push it 
          downwards, be sure to fix thoroughly. (See the Fig.8)
     2.   Attach the other end of the duct to adaptor B.
     3.   Put the end of duct to a nearby window.

B) PERMANENT-

     1.  Attach one end of the duct to the exhaust air outlet of the 
          mobile air conditioner. According to the arrow direction, 
          first fit the left side of the duct on the exhaust air panel, 
          then the right side duct. Push it downwards, be sure to fix
          thoroughly. (See the Fig.7)
      2. Install the adaptor A onto the wall by using 4 wall plug and
          screws, be sure to fix thoroughly. (See the Fig.9)
      3. Attach the other end of the duct to adaptor A.
      4. Cover the hole using the adaptor cap when not in use.

The duct can be compressed or extended between 20in 

and 80in, but it is desirable to keep the duct length to a 

minimum.

IMPORTANT:

     DO NOT OVER BEND THE DUCT (SEE Fig.10)

Adapter A

Rawlplugs

Skruer

max 47.25in

min  11.81in

Fig.8

Fig.9

Fig.10

11.81

in

11

.8

1in

Fig.7

Содержание MPF-12CR

Страница 1: ...PORTABLE AIR CONDITIONER OWNER S MANUAL Models MPF 12CR Thank you for purchasing this product Please read this Owner s Manual carefully before operating Table of Contents 1 MPF 10ER...

Страница 2: ...2 NAMES OF PARTS 3 ACCESSORIES 4 OPERATION PANEL OF THE AIR CONDITIONER 5 OPERATING INSTRUCTION FOR THE AIR CONDITIONER 6 INSTALLATION 7 MAINTENANCE 8 TROUBLE SHOOTING 9 REMOTE CONTROLLER 9 13 10 GUAR...

Страница 3: ...he bottom drain plug if the air conditioner will not be used for an extended period of time 7 Only run the unit on a flat stable surface and where the air conditioner is upright to ensure proper opera...

Страница 4: ...please refer to the installation instructions for their usage ALKALINE BATTERIES 2 1 1 REMOTE CONTROLLER WATER PUMP DRAIN HOSE SCREWS 2 NAMES OF PARTS OPRATION PANEL AIR OUTLET REMOTE CONTROLLER CAST...

Страница 5: ...Turn on off the unit MODES BUTTON Select the operation mode from COOL DRY FAN FAN SPEED BUTTON Press the button to select the fan speed from HIGH MED or LOW OPERATING PANEL TEMP SETTING BUTTON Press...

Страница 6: ...d 5 Press the on off button to turn on the unit 1 BEFORE USE Dehumidifying and Cooling Operations O O The operating range for cooling operating is 63 F 86 F If the cooling or dehumidifying operations...

Страница 7: ...SPEED button to choose the fan speed Do not put the duct to window 6 TIMER OPERATION Setting the on timer Press the TIMER ON button when the air conditioner is off Select the time in hours when you wo...

Страница 8: ...Attach the other end of the duct to adaptor B 3 Put the end of duct to a nearby window B PERMANENT 1 Attach one end of the duct to the exhaust air outlet of the mobile air conditioner According to th...

Страница 9: ...e the rubber blockage from the back drainage hole and drain the water off The unit will continue operating properly Drain Tank Safety Feature MAINTENANCE 1 BE SURE TO UNPLUG THE UNIT BEFORE CLEANING 2...

Страница 10: ...om temperature is lower than the set temperature Cooling mode The windows or doors in the room are not closed There are heat sources inside the room Exhaust air duct is not connected or blocked Temper...

Страница 11: ...9 REMOTE CONTROLLER FOR PORTABLE AIR CONDITIONER SET TEMPERATURE F AUTO COOL DRY HEAT FAN HIGH MED LOW TEMP MODE FAN SPEED TIMER OFF LOCK RESET ON OFF TIMER ON C OWNER S MANUAL...

Страница 12: ...ing heating type or heating pump type air conditioner Model R51H C is used for cooling only type air conditioner Warning 1 Be sure there are no barriers between the remote controller and the receiver...

Страница 13: ...the current settings are cancelled and the control will return to the initial settings 3 LOCK Button Push this button to lock in all the current settings To release settings push again 4 5 TIMER ON Bu...

Страница 14: ...o the directions and shown on the Remote Controller 2 To replace the old batteries use the same method as mentioned above 1 When replacing batteries do not use old batteries or a different type batter...

Страница 15: ...set the starting time NOTE The FAN ONLY mode cannot be used to control the temperature While in this mode only steps 1 3 and 4 may be performed 2 To set the stopping time 2 3 After setting the TIMER O...

Страница 16: ...he warranty service representative Exceptions This warranty will not apply 1 To malfunctions or damage other than caused by a defect in material or workmanship 2 To any damage abuse accident neglect a...

Страница 17: ......

Отзывы: