     Your window kit has been designed to fit most standard 
     vertical and horizontal opening window It 
     may be necessary for you to modify some aspects of 
     the installation procedures for certain window types. 
     Please refer to Fig.11 & 11a for the minimum and maximum 
     window openings.

Window Kit Installation

Horizontal 
window

Window Slider Kit 
Minimum:67.5cm(2.22ft).
Maxmum:123cm(4.04ft).

Window Slider Kit 
Minimum:67.5cm(2.22ft).
Maxmum:123cm(4.04ft).

Horizontal 
window

     This unit is equipped with an internal water tank, two full-safe
     switch mechanisms, one is used to control the water pump 
     drainage, the other is used to monitor the water level inside
     the internal water tank. When the water level reaches a 
     predetermined level, the full-safe switch mechanism is 
     activated. The digital display shows P1 and the water full
     indicator light illuminates. Carefully move the unit outside, 
     remove the rubber blockage from the back drainage hole 
     and drain the water off. The unit will continue operating 
     properly.

Drain Tank Safety Feature

MAINTENANCE

     1)  BE SURE TO UNPLUG THE UNIT BEFORE CLEANING.
     2)  DO NOT USE GASOLINE, THINNER OR OTHER CHEMICALS TO CLEAN THE UNIT.
     3)  DO NOT WASH THE UNIT DIRECTLY UNDER A TAP OR WITH  A  HOSE DUE TO ELECTRICAL 
     HAZARDS.
     4)  IF THE POWER CORD IS DAMAGED, IT SHOULD BE REPAIRED BY THE MANUFACTURER OR ITS 
     AUTHORIZED REPAIR AGENCY.

1   AIR FILTER

-    Clean the air filter at least once every two weeks to 
     prevent interior fan damage due to an accumulation of dust. 
-    Removal 
     Pull out the filter cover and remove the air filter from the 
     filter cover.
-    Cleaning 
      Wash the air filter by immersing it gently in warm water
      with a neutral detergent. Rinse the filter and let it dry. 
-     Mounting 
      Attach the air filter to the filter cover using the attachment
      hooks on the inner surface of the cover. Put the filter cover 
      back to the unit.

2   UNIT ENCLOSURE

-    Use a damp lint-free cloth to clean the unit enclosure. 
     Dry with a dry clean cloth.

Fig.11

Fig.11a

Fig.12

IMPORTANT:

Содержание MPF-12CR

Страница 1: ...PORTABLE AIR CONDITIONER OWNER S MANUAL Models MPF 12CR Thank you for purchasing this product Please read this Owner s Manual carefully before operating Table of Contents 1 MPF 10ER...

Страница 2: ...2 NAMES OF PARTS 3 ACCESSORIES 4 OPERATION PANEL OF THE AIR CONDITIONER 5 OPERATING INSTRUCTION FOR THE AIR CONDITIONER 6 INSTALLATION 7 MAINTENANCE 8 TROUBLE SHOOTING 9 REMOTE CONTROLLER 9 13 10 GUAR...

Страница 3: ...he bottom drain plug if the air conditioner will not be used for an extended period of time 7 Only run the unit on a flat stable surface and where the air conditioner is upright to ensure proper opera...

Страница 4: ...please refer to the installation instructions for their usage ALKALINE BATTERIES 2 1 1 REMOTE CONTROLLER WATER PUMP DRAIN HOSE SCREWS 2 NAMES OF PARTS OPRATION PANEL AIR OUTLET REMOTE CONTROLLER CAST...

Страница 5: ...Turn on off the unit MODES BUTTON Select the operation mode from COOL DRY FAN FAN SPEED BUTTON Press the button to select the fan speed from HIGH MED or LOW OPERATING PANEL TEMP SETTING BUTTON Press...

Страница 6: ...d 5 Press the on off button to turn on the unit 1 BEFORE USE Dehumidifying and Cooling Operations O O The operating range for cooling operating is 63 F 86 F If the cooling or dehumidifying operations...

Страница 7: ...SPEED button to choose the fan speed Do not put the duct to window 6 TIMER OPERATION Setting the on timer Press the TIMER ON button when the air conditioner is off Select the time in hours when you wo...

Страница 8: ...Attach the other end of the duct to adaptor B 3 Put the end of duct to a nearby window B PERMANENT 1 Attach one end of the duct to the exhaust air outlet of the mobile air conditioner According to th...

Страница 9: ...e the rubber blockage from the back drainage hole and drain the water off The unit will continue operating properly Drain Tank Safety Feature MAINTENANCE 1 BE SURE TO UNPLUG THE UNIT BEFORE CLEANING 2...

Страница 10: ...om temperature is lower than the set temperature Cooling mode The windows or doors in the room are not closed There are heat sources inside the room Exhaust air duct is not connected or blocked Temper...

Страница 11: ...9 REMOTE CONTROLLER FOR PORTABLE AIR CONDITIONER SET TEMPERATURE F AUTO COOL DRY HEAT FAN HIGH MED LOW TEMP MODE FAN SPEED TIMER OFF LOCK RESET ON OFF TIMER ON C OWNER S MANUAL...

Страница 12: ...ing heating type or heating pump type air conditioner Model R51H C is used for cooling only type air conditioner Warning 1 Be sure there are no barriers between the remote controller and the receiver...

Страница 13: ...the current settings are cancelled and the control will return to the initial settings 3 LOCK Button Push this button to lock in all the current settings To release settings push again 4 5 TIMER ON Bu...

Страница 14: ...o the directions and shown on the Remote Controller 2 To replace the old batteries use the same method as mentioned above 1 When replacing batteries do not use old batteries or a different type batter...

Страница 15: ...set the starting time NOTE The FAN ONLY mode cannot be used to control the temperature While in this mode only steps 1 3 and 4 may be performed 2 To set the stopping time 2 3 After setting the TIMER O...

Страница 16: ...he warranty service representative Exceptions This warranty will not apply 1 To malfunctions or damage other than caused by a defect in material or workmanship 2 To any damage abuse accident neglect a...

Страница 17: ......

Отзывы: