background image

5

O

O

O

O

2   COOLING OPERATION  (Operating temperature range: 

17 C-32 C/63 F-90 F

)

-    Press the 

 "

MODE

"

 button several times until the 

 "

COOL

"

 indicator light comes on. 

-    Press the 

 "

TEMP SETTING

"

 buttons

  " "

 or 

"

    

"

 to select your desired room temperature.

O

O

O

O

     (17 C-30 C/63 F-86 F)  
-    Press the 

"

FAN SPEED

"

 button to choose the fan speed. 

 

O

O

O

O

3   DEHUMIDIFYING OPERATION (Operating temperature range: 

13 C-32 C/55 F-90 F

)

-    Press the 

 "

MODE

"

 button several times until the 

 "

DRY

"

 indicator light comes on.    

-    The fan will run at a fixed speed at this setting.
-    Keep windows and doors closed for the best dehumidifying effect.
-    Do not put the duct to window.

4   HEATING OPERATION 

(Cooling only type without heat feature)

O

O

O

O

 

 

 

 

(Operating temperature range:5

C-30 C/41 F-86 F

)

 

-    Press the 

 "

MODE

"

 button several times until the  

"

HEAT

"

  indicator light comes on. 

-    Press the 

 "

TEMP SETTING

"

 buttons

  " "

 or 

"

    

"

 to select your desired room temperature.

O

O

O

O

     (17 C-30 C/63 F-86 F)  
-    Press the 

"

FAN SPEED

"

 button to choose the fan speed.

-    Do not put the duct to window.

 

5   FAN OPERATION

-    Press the 

 "

MODE

"

 button several times until the  

"

FAN 

"

 indicator light comes on. 

-    Press the 

"

FAN SPEED

"

 button to choose the fan speed.

-    Do not put the duct to window.

6   TIMER OPERATION

Setting the on timer:
-    Press the 

"

TIMER ON

"

  button when the air conditioner is off. Select the time (in hours) when you 

     would like the AC to turn on. 
-    The AC will display 

"

ON

"

-    The starting time is adjustable from 0 to 24 hours.
Setting the off timer:
-    Press the 

"

TIMER OFF

"

 button when the air conditioner is on. Select the time (in hours) when 

     you would like the AC to turn off.
-    The turning off time is adjustable from 0 to 24 hours.

7   WATER PUMP DRAINAGE

8   CONTINUOUS DRAINAGE

-    Connect the water pump drain hose to the unit before operating. When the water level of the internal
     water tank reaches a predetermined level, the water pump will be activated and drain the 
     condensed water outside through the connected drain hose. The maximum delivery lift is 3.5m (12 ft).
     (With this method of drainage, attach the rubber plug to the drainage hole at the bottom of the unit 
     to prevent continuous drainage. 

-    When you plan to leave this unit unused for a long time, remove the rubber plug from the drainage 
     hole at the bottom of the unit and attach a section of the continuous drain hose to drain hose 
     connector.  All the water in the water tank will drain outside through the drain hose. (Under this 
     condition, the water pump is not activated.)

Содержание MPF-12CR

Страница 1: ...PORTABLE AIR CONDITIONER OWNER S MANUAL Models MPF 12CR Thank you for purchasing this product Please read this Owner s Manual carefully before operating Table of Contents 1 MPF 10ER...

Страница 2: ...2 NAMES OF PARTS 3 ACCESSORIES 4 OPERATION PANEL OF THE AIR CONDITIONER 5 OPERATING INSTRUCTION FOR THE AIR CONDITIONER 6 INSTALLATION 7 MAINTENANCE 8 TROUBLE SHOOTING 9 REMOTE CONTROLLER 9 13 10 GUAR...

Страница 3: ...he bottom drain plug if the air conditioner will not be used for an extended period of time 7 Only run the unit on a flat stable surface and where the air conditioner is upright to ensure proper opera...

Страница 4: ...please refer to the installation instructions for their usage ALKALINE BATTERIES 2 1 1 REMOTE CONTROLLER WATER PUMP DRAIN HOSE SCREWS 2 NAMES OF PARTS OPRATION PANEL AIR OUTLET REMOTE CONTROLLER CAST...

Страница 5: ...Turn on off the unit MODES BUTTON Select the operation mode from COOL DRY FAN FAN SPEED BUTTON Press the button to select the fan speed from HIGH MED or LOW OPERATING PANEL TEMP SETTING BUTTON Press...

Страница 6: ...d 5 Press the on off button to turn on the unit 1 BEFORE USE Dehumidifying and Cooling Operations O O The operating range for cooling operating is 63 F 86 F If the cooling or dehumidifying operations...

Страница 7: ...SPEED button to choose the fan speed Do not put the duct to window 6 TIMER OPERATION Setting the on timer Press the TIMER ON button when the air conditioner is off Select the time in hours when you wo...

Страница 8: ...Attach the other end of the duct to adaptor B 3 Put the end of duct to a nearby window B PERMANENT 1 Attach one end of the duct to the exhaust air outlet of the mobile air conditioner According to th...

Страница 9: ...e the rubber blockage from the back drainage hole and drain the water off The unit will continue operating properly Drain Tank Safety Feature MAINTENANCE 1 BE SURE TO UNPLUG THE UNIT BEFORE CLEANING 2...

Страница 10: ...om temperature is lower than the set temperature Cooling mode The windows or doors in the room are not closed There are heat sources inside the room Exhaust air duct is not connected or blocked Temper...

Страница 11: ...9 REMOTE CONTROLLER FOR PORTABLE AIR CONDITIONER SET TEMPERATURE F AUTO COOL DRY HEAT FAN HIGH MED LOW TEMP MODE FAN SPEED TIMER OFF LOCK RESET ON OFF TIMER ON C OWNER S MANUAL...

Страница 12: ...ing heating type or heating pump type air conditioner Model R51H C is used for cooling only type air conditioner Warning 1 Be sure there are no barriers between the remote controller and the receiver...

Страница 13: ...the current settings are cancelled and the control will return to the initial settings 3 LOCK Button Push this button to lock in all the current settings To release settings push again 4 5 TIMER ON Bu...

Страница 14: ...o the directions and shown on the Remote Controller 2 To replace the old batteries use the same method as mentioned above 1 When replacing batteries do not use old batteries or a different type batter...

Страница 15: ...set the starting time NOTE The FAN ONLY mode cannot be used to control the temperature While in this mode only steps 1 3 and 4 may be performed 2 To set the stopping time 2 3 After setting the TIMER O...

Страница 16: ...he warranty service representative Exceptions This warranty will not apply 1 To malfunctions or damage other than caused by a defect in material or workmanship 2 To any damage abuse accident neglect a...

Страница 17: ......

Отзывы: