![Alcorn Mcbride V+ series Скачать руководство пользователя страница 261](http://html1.mh-extra.com/html/alcorn-mcbride/v-series/v-series_user-manual_2892709261.webp)
16-7
Appendix B
– Alcorn McBride Serial Control Protocols
Ap
p
end
ice
s
B
MIDI Control
Advantage:
Supported by most MIDI devices
Disadvantage:
Not bullet-proof
Alcorn McBride Show Controllers with a MIDI IN port can also be controlled
by the MIDI Control messages SYSEX, NOTE ON, and NOTE OFF.
Start a Sequence with SYSEX “GO CUE”
The SYSEX “GO CUE” message can be used to start a sequence. Here is the
general form:
0xF0 0x7F <target address> 0x02 0x7F 0x01 <data #1> <data #2> <data #3> 0xF7
The
<data #1>
byte is the ASCII hundreds digit of the sequence number
(sequence index + 1). For example, if you were starting sequence #104, the
<data #1>
byte is 0x31 (or “1”).
The
<data #2>
byte is the ASCII tens digit of the sequence number (sequence
index + 1). For example, if you were starting sequence #104, the
<data #2>
byte is 0x30 (or “0”).
The
<data #3>
byte is the ASCII ones digit of the sequence number (sequence
index + 1). For example, if you were starting sequence #104, the
<data #3>
byte is 0x34 (or “4”).
Here is an example Start Sequence #4 message sent from an Amiga (address
0xFF) to a Show Controller whose address is 0x00:
0xF0 0x7F 0x00 0x02 0x7F 0x01 0x30 0x30 0x34 0xF7
Set a State Variable
with SYSEX “SET”
The SYSEX “SET” message can be used to set the value of a State Variable.
Here is the general form:
0xF0 0x7F <target address> 0x02 0x7F 0x06 <data #1> 0x00 <data #2> <data #3> 0xF7
The
<data #1>
byte is the state variable index number. For example, if you
were setting variable #3, the
<data #1>
byte would be 0x03.
The
<data #2>
byte represents bits 0-6 of the desired value. For example, if the
desired value were 0x8E,
<data #2>
would be 0x0E.
The
<data #3>
byte represents the MSB (or bit 7) of the desired value. For
example, if the desired value were 0x8E,
<data #3>
would be 0x01.
Here is an example “Set Var #3 to 8E” message sent from an Amiga (address
0xFF) to a Show Controller whose address is 0x00:
0xF0 0x7F 0x00 0x02 0x7F 0x06 0x03 0x00 0x0E 0x01 0xF7
Содержание V+ series
Страница 2: ...User s Guide To Show Control by Alcorn McBride Inc...
Страница 7: ...Third Party Equipment 18 3 Index 19 1...
Страница 8: ......
Страница 14: ...1 6 Welcome...
Страница 28: ...3 14 Show Control Overview GoingToDayModeMsg ClearLine2Msg...
Страница 38: ...3 24 Show Control Overview...
Страница 82: ...4 44 WinScript User s Guide...
Страница 118: ......
Страница 144: ...6 26 Advanced WinScript Programming...
Страница 170: ...7 26 Application Notes...
Страница 220: ...13 8 DMX Machine Hardware Reference...
Страница 236: ...14 16 SMPTE Machine Hardware Reference...
Страница 254: ...15 18 Appendix A Adding User Defined Serial Protocols...
Страница 264: ......
Страница 268: ...18 4 Appendix D Available Accessories...