background image

Installation & User Manual 

Models: Alchemy RB700, RB1000 & RB1500

with Remote Control

Version 002. Dec. 2021

Содержание Alchemy RB1000

Страница 1: ...Installation User Manual Models Alchemy RB700 RB1000 RB1500 with Remote Control Version 002 Dec 2021...

Страница 2: ...ully for correct installation use and maintenance of the fireplace and familiarise yourself with the proper use of the product Operate the fireplace in accordance with the instructions provided so you...

Страница 3: ...4 1 Operating Remote Control and Turning ON Burner 18 4 2 Out of Fuel Notification and Refuelling 20 5 Safety Systems 21 5 1 Leak Detection Sensor 21 5 2 Overflow Detection Sensor 21 5 3 Bioethanol Fu...

Страница 4: ...4 1 Supplied Parts 5 Fuel Filling Funnel 1 Burner 2 Remote Control 3 RC Handset 4 x AAA Batteries 4 AC 220V 240V Mains Power Cable...

Страница 5: ...e Fire is located at minimum distance of 200cm Transport and or store fuel only in a plastic or metal container that is acceptable for use with the fuel and non red in colour VI Never smoke while refu...

Страница 6: ...t type of fuel 2 5 HOT SURFACE HAZARD I Due to high surface temperatures keep children pets clothing and furniture away from the fireplace as the appliance is hot while in operation contact with the f...

Страница 7: ...ilation to ensure air exchange in the room at least once per hour Do not start the device before a full installation has been completed Do not fill the fuel container before placing the device in its...

Страница 8: ...r cloth and avoid any naked flame around Please Note The fireplace gets hot during operation avoid touching it for 10 minutes after the flame is completely extinguished Do not fill up the Fuel TANK wh...

Страница 9: ...itive materials or devices above the fireplace as it can significantly limit the materials properties and lifetime The manufacturer will not bear any responsibility for the damage to heat sensitive ma...

Страница 10: ...NSTALLATION Methods 3 4 6 the glass should not be used and the optional part 11 top plate plain should be ordered Important Note the burner should not be installed where there will be excessive draugh...

Страница 11: ...osure Ensure the enclosure around the appliance is made from non combustible materials Any stud work introduced must be non combustible materials Any voids within the breast are recommended to be vent...

Страница 12: ...for 3 minutes and check again Repeat the procedure described above until the flames are reasonably level Alternatively the burner can sit into a recess and be sited on the burner enclosure frame The...

Страница 13: ...controls Excessive heat build up may cause the appliance to overheat and shut off Fig 3 Dependent on the installation method please ensure a min of 50cm2 cool air below the burner plate At a minimum...

Страница 14: ...vent manufacturer instructions prior to installation Intumescent vents will seal the air intake if temperatures rise above 110 120 C Sodium Silicate Intumescent to help prevent oxygen fuelling any fi...

Страница 15: ...f the TV must be recessed a minimum of 100mm at a minimum height of 900mm from the burner New construction method Recessing less than 100mm 0 50mm requires a min height of 1100mm 51 100mm requires a m...

Страница 16: ...as much as possible and aerated See fig 2 page 12 for full details Model Ventilation Area Minimum Room Size m3 RB700 The appliance requires the exchange of one room volume of air per hour 35 RB1000 T...

Страница 17: ...SUPPLY UNTIL AFTER THE APPLIANCE IS SAFELY INSTALLED Tilt the fire 15 20 degrees and slowly lower the fire into the recess Once the plug is below the rear lip bring the fire level and place down caref...

Страница 18: ...andset II To TURN ON hold power button until green bar fills The screen will display PRIMING for about 30 45 seconds followed by IGNITION III When the flame has established the screen will display the...

Страница 19: ...9 Burner is priming when the glow plug is heating up and the fuel starts pumping out as shown in the image Once the glow plug reaches required temperature and reached by the fuel the flame will ignite...

Страница 20: ...ng When the tank is empty or does not have sufficient amount of bioethanol a beep and message will appear on the display screen In order to light the Bio Fire the top access panel must be replaced in...

Страница 21: ...The Bio Fires have a leak detection sensor located underneath the burner on the lowest part of the sump as per image showing the sensor location Thus if there is a leak the fire will turn off itself A...

Страница 22: ...late or log plate G Check the safe operation of the appliance 6 1 Cleaning the Ceramics Remove the ceramic top plate as detailed above Gently clean the ceramics in the open air using a soft brush and...

Страница 23: ...Code in the DEVICE menu on the handset for further guidance Check fuel level by inspection through the fuel tank window check type of fuel used Repeat starting procedure until the Burner warms up and...

Страница 24: ...and make sure they are in correct position 2 No fuel reaching tank sensor IGNITION PROCESS Reason Not enough fuel in tank Solution Put more fuel into the tank 3 Thermocouple hot Hot Tray IGNITION PRO...

Страница 25: ...required period as flame did not reach it during ignition process due to fuel running out blockage in fuel lines or faulty pump Solution Check for leaks around fuel tank Check fuel refuel if no fuel...

Страница 26: ...carrying out any operations using the remote handset it is likely that it will go into power save mode Press the power button to reactivate IMPORTANT If your handset loses signal or needs to be replac...

Страница 27: ...ct options rotate dial until highlighted in RED and press select SET CLOCK DEVICE ADVANCED 1 1 SET CLOCK I Select CLOCK in the option menu and rotate touch dial until desired time is displayed II By p...

Страница 28: ...screen the PAIRING selection will appear 1 2 2 PAIRING DEVICE To pair a handset existing or new to the appliance the current pairing program must be deleted as shown previously I Ensure appliance is s...

Страница 29: ...29 1 3 1 SCREEN DIMMER I Scroll to ADVANCE menu and press select II This function dims the screen of the remote To switch dimmer on or off press SET option to toggle between ON and OFF 1 3 ADVANCED...

Страница 30: ...e side need to be pushed in as shown on images to release the top from the body Image above is pump inside the fire enclosure view from top The same step of removing Pump Top image shows pump without...

Страница 31: ...exi hose connectors highlighted in red Cables ties need to be cut off highlighted in yellow and the Pump Top flexi hoses can be pulled off the connectors To install new Pump Top follow steps in revers...

Страница 32: ...32 Appendix 3 Dimensions and Spare Parts RB700...

Страница 33: ...OMPLETE 1 5 RBIO 003 N A FUEL PUMP TOP 1 6 RBIO 004 A POWER CONTROL ASSEMBLY 1 7 RBIO 005 N A IEC POWER SOCKET 1 8 RBIO 006 N A POWER LEAD 1 9 RB700 003 A TOP PLATE WITH HOLES 1 10 RB700 004 A GLASS V...

Страница 34: ...34 Dimensions and Spare Parts RB1000...

Страница 35: ...OMPLETE 1 5 RBIO 003 N A FUEL PUMP TOP 1 6 RBIO 004 A POWER CONTROL ASSEMBLY 1 7 RBIO 005 N A IEC POWER SOCKET 1 8 RBIO 006 N A POWER LEAD 1 9 RB1000 003 A TOP PLATE WITH HOLES 1 10 RB1000 004 A GLASS...

Страница 36: ...36 Dimensions and Spare Parts RB1500...

Страница 37: ...OMPLETE 1 5 RBIO 003 N A FUEL PUMP TOP 1 6 RBIO 004 A POWER CONTROL ASSEMBLY 1 7 RBIO 005 N A IEC POWER SOCKET 1 8 RBIO 006 N A POWER LEAD 1 9 RB1500 003 A TOP PLATE WITH HOLES 1 10 RB1500 004 A GLASS...

Страница 38: ...38 NOTES...

Страница 39: ...They will need to investigate the matter and process the claim on your behalf if required The warranty must be registered within 28 days of installing the appliance Failure to register within this tim...

Страница 40: ...Alchemy Fires Ltd 194 196 Battersea Park Road London SW11 4ND...

Отзывы: