ReCOMMeNDeD veNTilATiON AND ROOM siziNg:
Recommended minimum ventilation sizes
:
iMPORTANT DeFiNiTiON:
Non-Combustible material: A material that does not react to heat.
•
Any
material which when tested to BS 476-11:1982 (2007) does not flame nor cause any rise in
temperature on the center (specimen).
•
Products
classified as non-combustible in tests following the procedures in BS 476-4:1970
(2007).
•
Any
material classified as class A1 in accordance with BS EN 13501-1:2002 Fire classification of
construction products and building elements. Classification using data from reaction to fire tests.
PLEASE NOTE THAT TIME RATED PLASTER BOARDS OF ANY TYPE ARE NOT SUITABLE
FOR THis CONTsRUCTiON, We ReCOMMeND ONlY CAlCiUM sililCATe & veRMiCUliTe
BASED BOARDS RATED TO A1.
The Bioethanol fire must be levelled as much as possible and aerated; See fig.2, page 12 for full
details.
Model
Ventilation Area
Minimum Room size (m
3
)
RB700
The appliance requires the exchange of
one room volume of air per hour
35
RB1000
The appliance requires the exchange of
one room volume of air per hour
45
RB1500
The appliance requires the exchange of
one room volume of air per hour
55
To calculate the room size, measure the Length (L), Width (W) and Height (H), and multiply all
measurements:
e.g. (L) 6.6m x (W) 3.8m x (H) 2.4m = 60.192m
3
Please note:
In order to use more than one appliance in the same room, multiply the appliances
installed by the recommended cubic capacity.
e.g. 2 x RB1000 appliances will require (45m
3
x2) = 90m
3
room size.
For new build and renovated properties with a lower air permeability:
While in operation this appliance emits heat, water vapour (H
2
O) and Carbon Dioxide (CO
2
),
therefore it is necessary to provide ventilation to the room of the appliance from an external
space as per Document F building regulations.
Содержание Alchemy RB1000
Страница 1: ...Installation User Manual Models Alchemy RB700 RB1000 RB1500 with Remote Control Version 002 Dec 2021...
Страница 32: ...32 Appendix 3 Dimensions and Spare Parts RB700...
Страница 34: ...34 Dimensions and Spare Parts RB1000...
Страница 36: ...36 Dimensions and Spare Parts RB1500...
Страница 38: ...38 NOTES...
Страница 40: ...Alchemy Fires Ltd 194 196 Battersea Park Road London SW11 4ND...