OmniSwitch 6850 Series Chassis and Hardware Components
Booting OmniSwitch 6850 Series Switches
OmniSwitch 6850/6850E Series Hardware Users Guide
June 2011
page 2-65
Booting OmniSwitch 6850 Series Switches
For information on booting stand-alone switches and switches in stacked configurations, refer to the
sections below.
Booting a Stand-Alone Switch
The OmniSwitch 6850 Series switch does not use an on/off switch. The power cord is the switch’s only
connect/disconnect device. The power connector socket is located on the switch’s rear panel. For more
information, refer to
“Rear Panel” on page 2-55
.
To boot the switch, plug the power cord (provided) into the power connector socket at the switch’s rear
panel. Next, plug the power cord into an easily-accessible power source, such as a grounded AC outlet or
an Uninterruptible Power Supply (UPS).
The switch immediately begins the boot process. Allow a few moments for the switch to boot completely,
then verify the status of all LEDs on the switch’s front panel. A successful boot for a stand-alone switch
displays the following LED states:
If any of the LED state differs from the states shown in the table above, refer to
page 2-53
for more infor-
mation. Contact Alcatel-Lucent Customer Support if the LED state persists.
For information on logging in and configuring your OmniSwitch 6850 Series switch, refer to the
OmniSwitch 6850 Series Getting Started Guide
and
OmniSwitch 6800/6850/9000 Series Switch Manage-
ment Guide
.
LED States for a Stand-Alone Switch
OK
Solid green
Blinking amber - Switch is operational but Auto-Configuration was not
successful.
PRI
Solid green
PWR
Solid green
BPS
Solid amber if BPS attached is failed and off when no operational
backup power supply (BPS) is attached; solid green if an operational
BPS is attached and operating normally.
XFP1
Off (applies to all OmniSwitch 6850 Series switches except for
OmniSwitch 6850-24X, OmniSwitch 6850-P24X, OmniSwitch 6850-
U24X, OmniSwitch 6850-48X, and OmniSwitch 6850-P48X). See
“Installing SFP and XFP Transceivers” on page 2-93
for more informa-
tion.
XFP2
Off (applies to all OmniSwitch 6850 Series switches except for
OmniSwitch 6850-24X, OmniSwitch 6850-P24X, OmniSwitch 6850-
U24X, OmniSwitch 6850-48X, and OmniSwitch 6850-P48X). See
“Installing SFP and XFP Transceivers” on page 2-93
for more informa-
tion.
Slot Indicator
1–8 (non-blinking), depending on the slot number value in the
boot.slot.cfg
file. The default value is 1.